HH3C-POWER-ETH-EXT-MIB

About this MIB

This MIB is an extension of POWER-ETHERNET-MIB. To implement this MIB, you must first implement relevant parts of POWER-ETHERNET-MIB, such as pethMainPseTable.

This MIB adds some objects which POWER-ETHERNET-MIB does not contain to monitor some specific aspects of entities for better and comprehensive management on devices.

MIB file name

hh3c-power-eth-ext.mib

Root object

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cCommon(2).hh3cPowerEthernetExt(14)

Scalar objects

hh3cPsePowerMaxValue

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPsePowerMaxValue (1.3.6.1.4.1.25506.2.14.5)

read-write

INTEGER

Standard MIB values.

PSE power management policy.

As per the MIB.

Applicable only to a device in standalone mode or member device 1 in an IRF fabric.

hh3cPsePolicyMode

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPsePolicyMode (1.3.6.1.4.1.25506.2.14.9)

read-write

INTEGER

disabled(1), priority(2)

PSE power management policy mode.

As per the MIB.

 

hh3cPDPolicyMode

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPDPolicyMode (1.3.6.1.4.1.25506.2.14.10)

read-write

INTEGER

disabled(1), priority(2)

PD power management policy mode.

As per the MIB.

 

hh3cPOEPortName

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPOEPortName (1.3.6.1.4.1.25506.2.14.12)

accessible-for-notify

DisplayString

Standard MIB values.

Name of the PoE port (PI).

As per the MIB.

 

Tabular objects

hh3cPsePortTable

About this table

Use this table to manage PSE ports.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Supported

Not supported

Supported

 

Columns

The table indexes are pethPsePortGroupIndex and pethPsePortIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPsePortFaultDescription (1.3.6.1.4.1.25506.2.14.1.1.2)

read-write

DisplayString

OCTET STRING (0..255)

Description about the precise PoE hardware state causing the pethPsePortDetectionStatus object to be in the fault state.

Not supported

hh3cPsePortPeakPower (1.3.6.1.4.1.25506.2.14.1.1.3)

read-write

Integer32

Standard MIB values.

Peak power of the PSE port, in milliwatts.

As per the MIB.

You can set the value to 0. Other values are not effective.

hh3cPsePortAveragePower (1.3.6.1.4.1.25506.2.14.1.1.4)

read-write

Integer32

Standard MIB values.

Average power of the PSE port, in milliwatts.

As per the MIB.

hh3cPsePortCurrentPower (1.3.6.1.4.1.25506.2.14.1.1.5)

read-only

Integer32

Standard MIB values.

Current power of the PSE port, in milliwatts.

As per the MIB.

hh3cPsePortPowerLimit (1.3.6.1.4.1.25506.2.14.1.1.6)

read-write

Integer32

Standard MIB values.

Power limit for the PSE port, in milliwatts.

As per the MIB.

hh3cPsePortProfileIndex (1.3.6.1.4.1.25506.2.14.1.1.7)

read-write

Integer32

Integer32 (0..100)

Index of the power profile currently associated with this port.

As per the MIB.

 

hh3cMainPseTable

About this table

Use this table to manage PSEs.

Support for operations

This table is not supported on non-default MDCs.

Create

Edit/Modify

Delete

Read

Not supported

Supported

Not supported

Supported

 

Columns

The table index is pethPsePortGroupIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cMainPsePowerLimit (1.3.6.1.4.1.25506.2.14.2.1.1)

read-write

Integer32

Standard MIB values.

Power limit for the PSE, in watts.

As per the MIB.

hh3cMainPseAveragePower (1.3.6.1.4.1.25506.2.14.2.1.2)

read-write

Integer32

Standard MIB values.

Average power of the PSE, in watts.

As per the MIB.

hh3cMainPsePeakPower (1.3.6.1.4.1.25506.2.14.2.1.3)

read-write

Integer32

Standard MIB values.

Peak power of the PSE, in watts.

As per the MIB.

hh3cMainGuaranteedPowerRemaining (1.3.6.1.4.1.25506.2.14.2.1.4)

read-only

Integer32

Standard MIB values.

Remaining guaranteed power of the PSE, in watts.

As per the MIB.

hh3cMainPsePriorityMode (1.3.6.1.4.1.25506.2.14.2.1.5)

read-write

INTEGER

disconnection(0), non-disconnection(1)

Describes or controls the priority mode on slot which must be enabled firstly. When a new card is inserted, and the power is overloaded, a value of disconnection(0) means that power will not be supplied to the low priority slot. A value of non-disconnection(1) means that power is supplied to the slot when a new card is inserted, and the power is overloaded.

Not supported.

hh3cMainPseLegacy (1.3.6.1.4.1.25506.2.14.2.1.6)

read-write

INTEGER

enable(0), disable(1)

Standard or nonstandard PD detection mode.

As per the MIB.

hh3cMainPsePowerPriority (1.3.6.1.4.1.25506.2.14.2.1.7)

read-write

INTEGER

critical(1), high(2), low(3)

Priority of the PSE.

As per the MIB.

 

hh3cPseProfilesTable

About this table

Use this table to manage power profiles.

Support for operations

Create

Edit/Modify

Delete

Read

Supported

Not supported

Supported

Supported

 

Columns

The table index is hh3cPseProfileIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPseProfileIndex (1.3.6.1.4.1.25506.2.14.7.1.1)

not-accessible

Integer32

Integer32 (1..100)

Profile index.

As per the MIB.

hh3cPseProfileName (1.3.6.1.4.1.25506.2.14.7.1.2)

read-create

DisplayString

OCTET STRING (1..15)

Profile name.

As per the MIB.

hh3cPseProfilePowerMode (1.3.6.1.4.1.25506.2.14.7.1.3)

read-create

INTEGER

powerDisabled(1), powerEnabled(2)

Power mode.

As per the MIB.

hh3cPseProfilePowerLimit (1.3.6.1.4.1.25506.2.14.7.1.4)

read-create

Integer32

Standard MIB values.

Power limit, in milliwatts.

As per the MIB.

hh3cPseProfilePriority (1.3.6.1.4.1.25506.2.14.7.1.5)

read-create

INTEGER

critical(1), high(2), low(3)

Port priority.

As per the MIB.

hh3cPseProfilePairs (1.3.6.1.4.1.25506.2.14.7.1.6)

read-create

INTEGER

signal(1), spare(2)

Pairs in use.

As per the MIB.

hh3cPseProfileApplyNum (1.3.6.1.4.1.25506.2.14.7.1.7)

read-only

Integer32

Standard MIB values.

Number of this profile being applied.

As per the MIB.

hh3cPseProfileRowStatus (1.3.6.1.4.1.25506.2.14.7.1.8)

read-create

RowStatus

active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)

Row status.

Supports only active, createAndGo, and destory.

This row cannot be deleted when the value of the hh3cPseProfileApplyNum is 0.

 

hh3cPOEModuleInfoTable

About this table

This table contains information about the PoE power supplies.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table index is hh3cPOEModuleIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPOEModuleIndex (1.3.6.1.4.1.25506.2.14.8.2.7.1.1)

accessible-for-notify

Integer32

Integer32 (1..2147483647)

PoE power supply index.

As per the MIB.

hh3cPOEModuleID (1.3.6.1.4.1.25506.2.14.8.2.7.1.2)

read-only

Integer32

Standard MIB values.

PoE power supply ID.

As per the MIB.

hh3cPOEModuleInfoPower (1.3.6.1.4.1.25506.2.14.8.2.7.1.3)

read-only

Integer32

Standard MIB values.

Power of the PoE power supply.

As per the MIB.

hh3cPOEModuleHardVerInfo (1.3.6.1.4.1.25506.2.14.8.2.7.1.4)

read-only

STRING

(SIZE (1..127))

Hardware version information of the PoE power supply.

As per the MIB.

 

hh3cPOEDCOutStateTable

About this table

This table contains the DC power output states of a PoE power supply.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table index is hh3cPOEDCOutStateIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPOEDCOutStateIndex (1.3.6.1.4.1.25506.2.14.8.3.2.1.1)

accessible-for-notify

Integer32

Integer32 (1..2147483647)

DC output power state index.

As per the MIB.

hh3cPOEDCOutDCVolAlarm (1.3.6.1.4.1.25506.2.14.8.3.2.1.2)

read-only

DCAlarmState

normal (1),

                                 underLimit (2),

aboveLimit (3),

fuseBroken (4),

switchOff  (5),

otherError (6)."

DC output power state alarm.

As per the MIB.

 

hh3cPOEDCOutInfoTable

About this table

This table contains the DC output information of a PoE power supply.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table index is hh3cPOEDCOutInfoIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPOEDCOutInfoIndex (1.3.6.1.4.1.25506.2.14.8.4.2.1.1)

accessible-for-notify

Integer32

Integer32 (1..2147483647)

DC output information index of a PoE power supply.

As per the MIB.

hh3cPOEDCOutVol (1.3.6.1.4.1.25506.2.14.8.4.2.1.2)

read-only

OCTET STRING

(SIZE (1..10))

DC output voltage.

As per the MIB.

hh3cPOEDCOutInfoLoadCur (1.3.6.1.4.1.25506.2.14.8.4.2.1.3)

read-only

OCTET STRING

(SIZE (1..10))

Total load current.

As per the MIB.

 

hh3cPOEACSwitchStateTable

About this table

This table contains the AC switch state of a PoE power supply.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table index is hh3cPOEACSwitchStateIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPOEACSwitchStateIndex (1.3.6.1.4.1.25506.2.14.8.5.2.1.1)

accessible-for-notify

Integer32

Integer32 (1..2147483647)

AC switch state index.

As per the MIB.

hh3cPOEACSwitchState (1.3.6.1.4.1.25506.2.14.8.5.2.1.2)

read-only

SwitchState

on       (1),

off       (2),

highVoltInput (3),

lowVoltInput   (4)"

AC switch state.

As per the MIB.

 

hh3cPOESwitchStateVolExTable

About this table

This table contains the all alarm status of the VOL status.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table index is hh3cPOESwitchStateVolExIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPOESwitchStateVolExIndex (1.3.6.1.4.1.25506.2.14.8.6.5.1.1)

accessible-for-notify

Integer32

Integer32 (1..2147483647)

Index of the VOL status.

As per the MIB.

hh3cPOESwitchStateInVolAB (1.3.6.1.4.1.25506.2.14.8.6.5.1.2)

read-only

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7)."

VOL AB alarm in the VOL status.

As per the MIB.

hh3cPOESwitchStateInVolBC (1.3.6.1.4.1.25506.2.14.8.6.5.1.3)

read-only

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7)."

VOL BC alarm in the VOL status.

As per the MIB.

hh3cPOESwitchStateInVolCA (1.3.6.1.4.1.25506.2.14.8.6.5.1.4)

read-only

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7)."

VOL CA alarm in the VOL status.

As per the MIB.

 

hh3cPOEAlarmStateInfoTable

About this table

This table contains all alarm states of PoE power supplies.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Not supported

Not supported

Supported

 

Columns

The table index is hh3cPOEAlarmModuleInfoIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cPOEAlarmModuleInfoIndex (1.3.6.1.4.1.25506.2.14.8.7.2.1.1)

accessible-for-notify

Integer32

Integer32 (1..2147483647)

Alarm information index.

As per the MIB.

hh3cPOEModuleDisconnect (1.3.6.1.4.1.25506.2.14.8.7.2.1.2)

read-only

ModuleAlarmState

normal (1),

alarm  (2).

PoE power supply disconnection alarm state.

As per the MIB.

hh3cPOEModuleInputError (1.3.6.1.4.1.25506.2.14.8.7.2.1.3)

read-only

ModuleAlarmState

normal (1),

alarm  (2).

Input error alarm state.

As per the MIB.

hh3cPOEModuleOutputError (1.3.6.1.4.1.25506.2.14.8.7.2.1.4)

read-only

ModuleAlarmState

normal (1),

alarm  (2).

Output error alarm state.

As per the MIB.

hh3cPOEModuleOverVoltage

(1.3.6.1.4.1.25506.2.14.8.7.2.1.5)

read-only

ModuleAlarmState

normal (1),

alarm  (2).

Overvoltage alarm state.

As per the MIB.

hh3cPOEModuleOverTemp (1.3.6.1.4.1.25506.2.14.8.7.2.1.6)

read-only

ModuleAlarmState

normal (1),

alarm  (2).

Overtemperature alarm.

As per the MIB.

hh3cPOEModuleFanError (1.3.6.1.4.1.25506.2.14.8.7.2.1.7)

read-only

ModuleAlarmState

normal (1),

alarm  (2).

Fan error alarm state.

As per the MIB.

hh3cPOEModuleShutdown (1.3.6.1.4.1.25506.2.14.8.7.2.1.8)

read-only

ModuleAlarmState

normal (1),

alarm  (2).

PoE power supply shut down alarm state.

As per the MIB.

hh3cPOEModuleCurRestricted (1.3.6.1.4.1.25506.2.14.8.7.2.1.9)

read-only

ModuleAlarmState

normal (1),

alarm  (2).

PoE power supply current limited alarm state.

As per the MIB.

 

Notifications

This section contains the HH3C-POWER-ETH-EXT-MIB notifications.

hh3cpsePDChangeNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.1

PD connection status changed

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when a PD is connected or disconnected.

System impact

No negative impact on the system.

Status control

ON

MIB: Set pethNotificationControlEnable to true(1).

OFF

MIB: Set pethNotificationControlEnable to false(2).

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.2.1.105.1.1.1.6 (pethPsePortDetectionStatus)

PD detection status of the PSE port.

pethPsePortGroupIndex

pethPsePortIndex

INTEGER

disabled(1), searching(2), deliveringPower(3), fault(4), test(5), otherFault(6)

 

Recommended action

Check the PD connection and make sure the PD is connected correctly.

No action is required if the PD is disconnected or connected on purpose.

hh3cPOEDisconnectNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.2

PoE power supply disconnected.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when a PoE power supply is disconnected.

System impact

No negative impact on the system.

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPOEAlarmModuleInfoIndex)

PoE power supply alarm information index.

hh3cPOEAlarmModuleInfoIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.2 (hh3cPOEModuleDisconnect)

Disconnection alarm state of the PoE power supply.

hh3cPOEAlarmModuleInfoIndex

ModuleAlarmState

                              normal (1),

alarm  (2)

Recommended action

Check the power supply. Locate and resolve the issues.

hh3cPOEInputErrorNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.3

PoE power supply input error.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when an input error occurs on a PoE power supply.

System impact

The PoE power supply cannot be used.

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPOEAlarmModuleInfoIndex)

PoE power supply alarm information index.

hh3cPOEAlarmModuleInfoIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.3 (hh3cPOEModuleInputError)

Input error alarm of the PoE power supply.

hh3cPOEAlarmModuleInfoIndex

ModuleAlarmState

                              normal (1),

alarm  (2)

Recommended action

Contact H3C Support for help.

hh3cPOEOutputErrorNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.4

PoE power supply output error.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when an output error occurs on a PoE power supply.

System impact

The PoE power supply cannot be used.

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPOEAlarmModuleInfoIndex)

PoE power supply alarm information index.

hh3cPOEAlarmModuleInfoIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.4 (hh3cPOEModuleOutputError)

Output error alarm of the PoE power supply.

hh3cPOEAlarmModuleInfoIndex

ModuleAlarmState

normal (1),

alarm  (2)

 

Recommended action

Contact H3C Support for help.

hh3cPOEOverVoltageNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.5

PoE power supply overvoltage.

Informational

Warning

N/A

ON

Notification triggers

This notification is generated when an overvoltage occurs on a PoE power supply

System impact

The voltage of the PoE power supply is too high.

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPOEAlarmModuleInfoIndex)

PoE power supply alarm information index.

hh3cPOEAlarmModuleInfoIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.5 (hh3cPOEModuleOverVoltage)

Overvoltage alarm of the PoE power supply.

hh3cPOEAlarmModuleInfoIndex

ModuleAlarmState

                              normal (1),

alarm  (2)

Recommended action

Contact H3C Support for help.

hh3cPOEOverTempNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.6

PoE power supply overtemperature

Informational

Warning

N/A

ON

Notification triggers

This notification is generated when an overtemperature occurs on a PoE power supply.

System impact

 

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPOEAlarmModuleInfoIndex)

PoE power supply alarm information index.

hh3cPOEAlarmModuleInfoIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.5 (hh3cPOEModuleOverTemp)

Overtemperature alarm of the PoE power supply.

hh3cPOEAlarmModuleInfoIndex

ModuleAlarmState

                              normal (1),

alarm  (2)."

Recommended action

Contact H3C Support for help.

hh3cPOEFanErrorNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.7

PoE power supply fan error.

Informational

Warning

N/A

ON

Notification triggers

This notification is generated when a fan error occurs on a PoE power supply.

System impact

 

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPOEAlarmModuleInfoIndex)

PoE power supply alarm information index.

hh3cPOEAlarmModuleInfoIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.7 (hh3cPOEModuleFanError)

Fan error alarm of the PoE power supply.

hh3cPOEAlarmModuleInfoIndex

ModuleAlarmState

                              normal (1),

alarm  (2)."

Recommended action

Contact H3C Support for help.

hh3cPOEModuleShutdownNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.8

PoE power supply shut down.

Informational

Warning

N/A

ON

Notification triggers

This notification is generated when a PoE power supply is shut down.

System impact

The PoE power supply cannot be used.

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPOEAlarmModuleInfoIndex)

PoE power supply alarm information index.

hh3cPOEAlarmModuleInfoIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.8 (hh3cPOEModuleShutdown)

PoE power supply shutdown alarm.

hh3cPOEAlarmModuleInfoIndex

ModuleAlarmState

                              normal (1),

alarm  (2)."

Recommended action

Contact H3C Support for help.

hh3cPOECurRestrictedNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.9

The current of the PoE power supply was limited.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when the current of a PoE power supply is limited.

System impact

 

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPOEAlarmModuleInfoIndex)

PoE power supply alarm information index.

hh3cPOEAlarmModuleInfoIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.9 (hh3cPOEModuleCurRestricted)

PoE power supply current limited alarm.

hh3cPOEAlarmModuleInfoIndex

ModuleAlarmState

                              normal (1),

alarm  (2)."

Recommended action

Contact H3C Support for help.

hh3cPOEACSwitchNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.10

AC input switch alarm

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when an AC input switch alarm occurs on a PoE power supply.

System impact

 

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.5.2.1.1 (hh3cPOEACSwitchStateIndex)

PoE power supply alarm information index.

hh3cPOEACSwitchStateIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.5.2.1.2 (hh3cPOEACSwitchState)

AC input switch alarm of the PoE power supply.

hh3cPOEACSwitchStateIndex

SwitchState

on            (1),

off            (2),

highVoltInput  (3),

lowVoltInput   (4)

Recommended action

Contact H3C Support for help.

hh3cPOEACInCurANotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.11

AC input current A alarm.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when an AC input current A alarm occurs on a PoE power supply.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.6.2

(hh3cPOEInCurAState)

Current A state alarm in the input of the PoE power supply.

hh3cPOEInCurStateModuleNum

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7).

Recommended action

Contact H3C Support for help.

hh3cPOEACInCurBNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.12

AC input current B alarm.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when an AC input current B alarm occurs on a PoE power supply.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.6.3

(hh3cPOEInCurBState)

Current B state alarm in the input of the PoE power supply.

hh3cPOEInCurStateModuleNum

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7).

Recommended action

Contact H3C Support for help.

hh3cPOEACInCurCNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.13

AC input current C state alarm.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when the AC input current C state alarm occurs on a PoE power supply.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.6.4

(hh3cPOEInCurCState)

AC input current C alarm state of a PoE power supply.

hh3cPOEInCurStateModuleNum

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7).

Recommended action

Contact H3C Support for help.

hh3cPOEACSwitchVolABNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.14

AC input voltage AB state alarm.

Informational

Warning

N/A

ON

Notification triggers

This notification is generated when an AC input voltage AB state alarm occurs on a PoE power supply.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.6.5.1.1 (hh3cPOESwitchStateVolExIndex)

VOL status index.

hh3cPOESwitchStateVolExIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.6.5.1.2 (hh3cPOESwitchStateInVolAB)

VOL AB alarm state in the VOL status.

hh3cPOESwitchStateVolExIndex

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7).

Recommended action

Contact H3C Support for help.

hh3cPOEACSwitchVolBCNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.15

AC input voltage BC state alarm.

Informational

Warning

N/A

ON

Notification triggers

This notification is generated when an AC input voltage BC state alarm occurs on a PoE power supply.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.6.5.1.1 (hh3cPOESwitchStateVolExIndex)

VOL status index.

hh3cPOESwitchStateVolExIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.6.5.1.3 (hh3cPOESwitchStateInVolBC)

VOL BC alarm state in the VOL status.

hh3cPOESwitchStateVolExIndex

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7).

Recommended action

Contact H3C Support for help.

hh3cPOEACSwitchVolCANotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.16

AC input voltage CA state alarm.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when an AC input voltage CA state alarm occurs on a PoE power supply.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.6.5.1.1 (hh3cPOESwitchStateVolExIndex)

VOL status index.

hh3cPOESwitchStateVolExIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.6.5.1.3 (hh3cPOESwitchStateInVolCA)

VOL CA alarm state in the VOL status.

hh3cPOESwitchStateVolExIndex

ACAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

lackPhrase (4),

fuseBroken (5),

switchOff  (6),

otherError (7).

Recommended action

Contact H3C Support for help.

hh3cPOEDCOutVolNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.17

DC output alarm.

Informational

Warning

N/A

ON

Notification triggers

This notification is generated when a DC output alarm occurs on a PoE power supply.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.3.2.1.1 (hh3cPOEDCOutStateIndex)

PoE power supply alarm information index.

hh3cPOEDCOutStateIndex

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.3.2.1.2 (hh3cPOEDCOutDCVolAlarm)

DC output power alarm of the PoE power supply.

hh3cPOEDCOutStateIndex

DCAlarmState

normal     (1),

underLimit (2),

aboveLimit (3),

fuseBroken (4),

switchOff  (5),

otherError (6).

Recommended action

Contact H3C Support for help.

hh3cPOEShutdownNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.18

PoE power supply shut down.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when a PoE power supply is shut down.

System impact

The PoE power supply cannot be used.

Status control

None.

Recommended action

None.

hh3cPOETrackNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.19

PD connected to a PoE port unreachable.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when the PD connected to a PI cannot be reached.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.1.1.1.8 (hh3cPsePortTrackAction)

Action taken when the state of the track entry associated with the PoE port changes from positive to negative.

hh3cPOEAlarmModuleInfoIndex

INTEGER

none(0),

alarm(1),

alarmRebootPD(2)

 

Recommended action

Contact H3C Support for help.

hh3cPOEPdClassInvalid

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.20

A PD of invalid class was detected.

Informational

Major

N/A

ON

 

Notification triggers

This notification is generated when a PD of invalid class is detected.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Objects

OID (object name)

Description

Index nodes

Type

Value range

 (1.3.6.1.4.1.25506.2.14.12) hh3cPOEPortName

PI name.

N/A

DisplayString

Standard MIB values.

 

Recommended action

To resolve this issue, verify that the PD complies with the PoE standard.

hh3cPOEPdClassOvercurrent

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.21

A PD of overcurrent class was detected

Informational

Major

N/A

ON

 

Notification triggers

This notification is generated when a PD of overcurrent class is detected.

System impact

Power supply to PDs might be affected.

Status control

This notification cannot be disabled.

Objects

OID (object name)

Description

Index nodes

Type

Value range

 (1.3.6.1.4.1.25506.2.14.12) hh3cPOEPortName

PI name.

N/A

DisplayString

Standard MIB values.

 

Recommended action

Disconnect the PD.

hh3cPOEPdPowerOvercurrent

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.6.22

PD overcurrent occurred.

Informational

Major

N/A

ON

 

Notification triggers

This notification is generated when PD overcurrent occurs on a port.

System impact

Power supply to PDs might be affected.

Status control

This notification cannot be disabled.

Objects

OID (object name)

Description

Index nodes

Type

Value range

(1.3.6.1.4.1.25506.2.14.12) hh3cPOEPortName

PI name.

N/A

DisplayString

Standard MIB values.

 

Recommended action

Disconnect the PD.

hh3cPsePDDisableNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.14.11.0.1

Power supply to a PD terminated.

Informational

Warning

N/A

ON

 

Notification triggers

This notification is generated when power supply to a PD is terminated.

System impact

N/A

Status control

None.

Objects

OID (object name)

Description

Index nodes

Type

Value range

1.3.6.1.4.1.25506.2.14.8.7.2.1.1 (hh3cPsePortGroupIndex)

PSE port group index.

hh3cPseNotificationObjects

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.3 (hh3cPsePortIndex)

PSE port index.

hh3cPseNotificationObjects

Integer32

Integer32 (1..2147483647)

1.3.6.1.4.1.25506.2.14.8.7.2.1.3 (hh3cPsePortDisableInfo)

Reason that caused failure of the PSE port to supply power.

hh3cPseNotificationObjects

Hh3cPDDisableState

unknown(0),

overInrush(1),

lessMPSCurrent(2),

peakPower(3),

overVoltage(4),

underVoltage(5),

overTemperature(6),

shortCircuit(7).

 

Recommended action

Contact H3C Support for help.

 

 

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us