02-Device Management

HomeSupportRoutersCR16000-M SeriesDiagnose & MaintainAlarms ReferencesH3C CR16000-M Routers Alarm Reference-R838x-6W10002-Device Management
03-HH3C-ENTITY-EXT-MIB
Title Size Download
03-HH3C-ENTITY-EXT-MIB 1.69 MB

Contents

HH3C-ENTITY-EXT-MIB· 1

About this MIB· 1

MIB file name· 9

Notifications· 9

hh3cEntityExtTemperatureThresholdNotification· 9

hh3cEntityExtCpuUsageThresholdNotfication· 11

hh3cEntityExtMemUsageThresholdNotification· 12

hh3cEntityExtCriticalTemperatureThresholdNotification· 13

hh3cEntityExtSFPAlarmOn· 14

hh3cEntityExtSFPAlarmOff 15

hh3cEntityInsert 16

hh3cEntityExtFaultAlarmOn· 18

hh3cEntityExtFaultAlarmOff 20

hh3cEntityExtTemperatureLower 21

hh3cEntityExtTemperatureTooUp· 22

hh3cEntityExtTemperatureNormal 23

hh3cEntityExternalAlarmOccur 24

hh3cEntityExternalAlarmRecover 25

hh3cEntityExtCpuUsageThresholdRecover 26

hh3cEntityExtMemUsageThresholdRecover 27

hh3cEntityExtMemAllocatedFailed· 28

hh3cEntityExtECCParityAlarm·· 29

hh3cEntityExtFanDirectionNotPreferred· 29

hh3cEntityExtMemUsageThresholdOverTrap· 30

hh3cEntityExtMemUsageThresholdRecoverTrap· 32

hh3cEntityExtVoltageLower 35

hh3cEntityExtVoltageTooLow· 36

hh3cEntityExtVoltageHigher 37

hh3cEntityExtVoltageTooHigh· 38

hh3cEntityExtSFPAlarmOnEx· 39

hh3cEntityExtSFPAlarmOffEx· 40

h3cEntityExtSFPPhony· 41

hh3cEntityExtSystemFatalAlarmOccur 42

hh3cEntityExtSystemFatalAlarmClear 43

hh3cEntityExtSystemAlarmOccur 44

hh3cEntityExtSystemAlarmClear 45

hh3cEntityExtSystemWarningOccur 46

hh3cEntityExtSystemWarningClear 47

hh3cEntityExtBoardFatalAlarmOccur 48

hh3cEntityExtBoardFatalAlarmClear 49

hh3cEntityExtBoardAlarmOccur 50

hh3cEntityExtBoardAlarmClear 51

hh3cEntityExtBoardWarningOccur 52

hh3cEntityExtBoardWarningClear 53

hh3cEntityExtPowerFatalAlarmOccur 54

hh3cEntityExtPowerFatalAlarmClear 55

hh3cEntityExtPowerAlarmOccur 56

hh3cEntityExtPowerAlarmClear 57

hh3cEntityExtPowerWarningOccur 58

hh3cEntityExtPowerWarningClear 59

hh3cEntityExtFanFatalAlarmOccur 60

hh3cEntityExtFanFatalAlarmClear 61

hh3cEntityExtFanAlarmOccur 62

hh3cEntityExtFanAlarmClear 63

hh3cEntityExtFanWarningOccur 64

hh3cEntityExtFanWarningClear 65

hh3cEntityExtVoltageFatalAlarmOccur 66

hh3cEntityExtVoltageFatalAlarmClear 67

hh3cEntityExtVoltageAlarmOccur 68

hh3cEntityExtVoltageAlarmClear 69

hh3cEntityExtVoltageWarningOccur 70

hh3cEntityExtVoltageWarningClear 71

hh3cEntityExtTemperatureFatalAlarmOccur 72

hh3cEntityExtTemperatureFatalAlarmClear 74

hh3cEntityExtTemperatureAlarmOccur 75

hh3cEntityExtTemperatureAlarmClear 76

hh3cEntityExtTemperatureWarningOccur 77

hh3cEntityExtTemperatureWarningClear 78

hh3cEntityExtClockFatalAlarmOccur 79

hh3cEntityExtClockFatalAlarmClear 80

hh3cEntityExtClockAlarmOccur 81

hh3cEntityExtClockAlarmClear 82

hh3cEntityExtClockWarningOccur 83

hh3cEntityExtClockWarningClear 84

hh3cEntityExtDiskFatalAlarmOccur 85

hh3cEntityExtDiskFatalAlarmClear 86

hh3cEntityExtDiskAlarmOccur 87

hh3cEntityExtDiskAlarmClear 88

hh3cEntityExtDiskWarningOccur 89

hh3cEntityExtDiskWarningClear 90

hh3cEntityExtOpticalFatalAlarmOccur 91

hh3cEntityExtOpticalFatalAlarmClear 92

hh3cEntityExtOpticalAlarmOccur 93

hh3cEntityExtOpticalAlarmClear 94

hh3cEntityExtOpticalWarningOccur 95

hh3cEntityExtOpticalWarningClear 96

hh3cEntityExtInternalLinkFatalAlarmOccur 97

hh3cEntityExtInternalLinkFatalAlarmClear 98

hh3cEntityExtInternalLinkAlarmOccur 99

hh3cEntityExtInternalLinkAlarmClear 100

hh3cEntityExtInternalLinkWarningOccur 101

hh3cEntityExtInternalLinkWarningClear 102

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10433003) 103

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10433003) 104

hh3cEntityExtTemperatureAlarmOccur(hh3cEntityExtErrorCode=10433004) 105

hh3cEntityExtTemperatureAlarmClear(hh3cEntityExtErrorCode=10433004) 106

hh3cEntityExtFanAlarmOccur(hh3cEntityExtErrorCode=10300001) 108

hh3cEntityExtFanAlarmClear(hh3cEntityExtErrorCode=10300001) 109

hh3cEntityExtFanAlarmOccur(hh3cEntityExtErrorCode=10300002) 110

hh3cEntityExtFanAlarmClear(hh3cEntityExtErrorCode=10300002) 111

hh3cEntityExtFanAlarmOccur(hh3cEntityExtErrorCode=10300008) 112

hh3cEntityExtFanAlarmClear(hh3cEntityExtErrorCode=10300008) 113

hh3cEntityExtFanAlarmOccur(hh3cEntityExtErrorCode=20300008) 114

hh3cEntityExtFanAlarmClear(hh3cEntityExtErrorCode=20300008) 115

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=30441001) 116

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=30441001) 117

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=10200012) 118

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=10200012) 119

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=10200011) 120

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=10200011) 121

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=10200024) 122

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=10200024) 123

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=10200003) 124

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=10200003) 125

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40441001) 126

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=40441001) 127

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=10400006) 128

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=10400006) 129

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=10400004) 130

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=10400004) 131

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=20400004) 132

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=20400004) 133

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=30400004) 134

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=30400004) 135

hh3cEntityExtSystemWarningOccur(hh3cEntityExtErrorCode=10100005) 136

hh3cEntityExtSystemWarningClear(hh3cEntityExtErrorCode=10100005) 137

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=10429001) 138

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=10429001) 139

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=20429001) 140

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=20429001) 141

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=50429001) 142

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=50429001) 143

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=60429001) 144

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=60429001) 145

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10420001) 146

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10420001) 147

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10430001) 148

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10430001) 149

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10430002) 150

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10430002) 151

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10441001) 152

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10441001) 153

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=60440009) 154

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=60440009) 155

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10443001) 156

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10443001) 157

hh3cEntityExtClockAlarmOccur(hh3cEntityExtErrorCode=100432022) 158

hh3cEntityExtClockAlarmClear(hh3cEntityExtErrorCode=100432022) 159

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10440016) 160

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10440016) 161

hh3cEntityExtSystemWarningOccur(hh3cEntityExtErrorCode=10482009) 162

hh3cEntityExtSystemWarningClear(hh3cEntityExtErrorCode=1010482009) 163

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50441001) 164

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=50441001) 165

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=10420002) 166

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=20420002) 167

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=20420002) 168

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=30420002) 169

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=30420002) 170

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=40420002) 172

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=40420002) 173

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=50420002) 174

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=50420002) 175

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=60420002) 176

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=60420002) 178

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=70420002) 179

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=70420002) 180

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=80420002) 181

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=80420002) 182

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=90420002) 184

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=90420002) 185

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=100420002) 186

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=100420002) 187

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=110420002) 188

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=110420002) 190

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=120420002) 191

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=120420002) 192

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=10420004) 193

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=10420004) 194

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=20420004) 196

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=20420004) 197

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=30420004) 198

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=30420004) 199

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=40420004) 200

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=40420004) 202

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=50420004) 203

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=50420004) 204

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=60420004) 205

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=60420004) 206

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=70420004) 208

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=70420004) 209

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=80420004) 210

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=80420004) 211

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=90420004) 212

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=90420004) 214

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=100420004) 215

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=100420004) 216

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=110420004) 217

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=110420004) 218

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=120420004) 220

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=120420004) 221

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=10100007· 222

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=10100007· 223

hh3cEntityExtSystemWarningOccur(hh3cEntityExtErrorCode=20100005) 224

hh3cEntityExtSystemWarningClear(hh3cEntityExtErrorCode=10100006) 225

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10540001) 226

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10540001) 227

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20420001) 228

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20420001) 229

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=70429001) 230

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=70429001) 231

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20441001) 232

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20441001) 233

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10400005) 234

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10400005) 235

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=20200012) 236

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=20200012) 237

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0474003) 238

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0474003) 239

hh3cEntityExtInternalLinkAlarmOccur(hh3cEntityExtErrorCode=0474002) 240

hh3cEntityExtInternalLinkAlarmClear(hh3cEntityExtErrorCode=0474002) 241

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0474001) 242

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0474001) 243

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0474011) 244

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0474011) 245

hh3cEntityExtInternalLinkAlarmOccur(hh3cEntityExtErrorCode=0428001) 246

hh3cEntityExtInternalLinkAlarmClear(hh3cEntityExtErrorCode=0428001) 247

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0428002) 248

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=0428002) 249

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0427002) 250

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=0427002) 251

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=0422002) 252

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=0422003) 253

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10432016) 254

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10432016) 255

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20432016) 256

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20432016) 257

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=30432016) 258

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=30432016) 259

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40432016) 260

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=40432016) 261

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50432016) 262

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=50432016) 263

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=60432016) 264

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=60432016) 265

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10440003) 266

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10440003) 267

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20440003) 268

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20440003) 269

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=30440003) 270

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=30440003) 271

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40440003) 272

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=40440003) 273

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50440003) 274

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=50440003) 275

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10440009) 276

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10440009) 277

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20440009) 278

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20440009) 279

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10442001) 280

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10442001) 281

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=10440008) 282

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=10440008) 283

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=20440008) 284

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=20440008) 285

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=30440008) 286

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=30440008) 287

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=10428002) 288

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=10428002) 289

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=10428002) 290

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=20428002) 291

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=30428002) 292

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=30428002) 293

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=40428002) 294

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=40428002) 295

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40440009) 296

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40440009) 297

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50440009) 298

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50440009) 299

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0423033) 300

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=0423033) 301

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0422016) 302

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=0422016) 303

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0428002) 304

hh3cEntityExtInternalLinkAlarmOccur(hh3cEntityExtErrorCode=0479003) 305

hh3cEntityExtInternalLinkAlarmClear(hh3cEntityExtErrorCode=0479003) 306

hh3cEntityExtInternalLinkAlarmOccur(hh3cEntityExtErrorCode=0473002) 307

hh3cEntityExtInternalLinkAlarmClear(hh3cEntityExtErrorCode=0473002) 308

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0479001) 309

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0479001) 310

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0479002) 311

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0479002) 312

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=0425001) 313

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=0425001) 314

 

 


HH3C-ENTITY-EXT-MIB

About this MIB

Use this MIB to obtain entity extended information. Access this MIB to monitor specific entity data, which facilitates management and monitoring on the product through network management.

Products supporting this MIB must first support the ENTITY-MIB MIB.

The following tables show the relationship between the entity extended properties and device entities. Implementation varies by product.

Entity

hh3cEntityExtAdminStatus (R/W)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

No

port

Yes

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtOperStatus (R)

chassis

No

backplane

No

container

No

power Supply

Yes

fan

Yes

sensor

No

module

Yes

port

Yes

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtStandbyStatus (R)

chassis

No

backplane

No

container

No

powerSupply

No

fan

Yes

sensor

No

module

Yes

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtAlarmLight (R)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

No

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtCpuUsage (R)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes(Only support the Module Level1)

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtCpuUsageThreshold (R/W)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes(Only support the Module Level1)

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtMemUsage (R)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes(Only support the Module Level1)

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtMemUsageThreshold(R/W)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes(Only support the Module Level1)

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtMemSize (R)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes(Only support the Module Level1)

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtUpTime (R)

chassis

Yes

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

No

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtTemperature (R)

chassis

No

backplane

No

container

No

powerSupply

Yes

fan

Yes

sensor

Yes

module

Yes

port

No

stack

No

other

Yes

unknown

No

 

Entity

hh3cEntityExtTemperatureThreshold(R/W)

chassis

No

backplane

No

container

No

powerSupply

Yes

fan

Yes

sensor

Yes

module

Yes

port

No

stack

No

other

Yes

unknown

No

 

Entity

hh3cEntityExtVoltage(R)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

No

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtVoltageLowThreshold(R/W)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

No

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtVoltageHighThreshold(R/W)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

No

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtCriticalTemperatureThreshold(R/W)

chassis

No

backplane

No

container

No

powerSupply

No

fan

No

sensor

Yes

module

No

port

No

stack

No

other

No

unknown

No

 

Entity

hh3cEntityExtMacAddress (R)

chassis

Yes

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

No

port

No

stack

Yes

other

No

unknown

No

 

Entity

hh3cEntityExtErrorStatus (R)

chassis

No

backplane

Yes

container

Yes

powerSupply

Yes

fan

Yes

sensor

Yes

module

No

port

Yes

stack

No

other

Yes

unknown

Yes

 

Entity

hh3cEntityExtManuSerialNum (R)

chassis

Yes

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes

port

No

cpu

No

 

Entity

hh3cEntityExtManuBuildInfo (R)

chassis

Yes

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes

port

No

cpu

No

 

Entity

hh3cEntityExtMacAddressCount (R)

chassis

Yes

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes

port

Yes

cpu

No

 

Entity

hh3cEntityExtManuBOM (R)

chassis

Yes

backplane

No

container

No

powerSupply

No

fan

No

sensor

No

module

Yes

port

No

cpu

No

 

Entity

(R/W: Read/Write)

POWERSUPPLY

FAN

CHASSIS

CONTAINER

MODULE

PORT

CPU

hh3cEntityExtAdminStatus (R/W)

 

 

 

 

 

Yes

 

hh3cEntityExtOperStatus (R)

Yes

Yes

 

 

Yes

Yes

 

hh3cEntityExtStandbyStatus (R)

 

Yes

 

 

Yes

 

 

hh3cEntityExtAlarmLight (R)

 

 

 

 

 

 

 

hh3cEntityExtCpuUsage (R)

 

 

 

 

Yes

 

 

hh3cEntityExtCpuUsageThreshold (R/W)

 

 

 

 

Yes

 

 

hh3cEntityExtMemUsage (R)

 

 

 

 

Yes

 

 

hh3cEntityExtMemUsageThreshold(R/W)

 

 

 

 

Yes

 

 

hh3cEntityExtMemSize (R)

 

 

 

 

Yes

 

 

hh3cEntityExtUpTime (R)

 

 

Yes

 

 

 

 

hh3cEntityExtTemperature (R)

 

 

 

 

 

 

 

hh3cEntityExtTemperatureThreshold (R/W)

 

 

 

 

 

 

 

hh3cEntityExtVoltage (R)

 

 

 

 

 

 

 

hh3cEntityExtVoltageLowThreshold (R/W)

 

 

 

 

 

 

 

hh3cEntityExtVoltageHighThreshold (R/W)

 

 

 

 

 

 

 

hh3cEntityExtCriticalTemperatureThreshold

 

 

 

 

 

 

 

hh3cEntityExtMacAddress

 

 

Yes

 

 

 

 

hh3cEntityExtErrorStatus

 

 

 

 

 

 

 

 

 

NOTE:

·     Yes indicates that the extended property is supported.

·     If the read operation returns no such name/instance, the object is not supported in the current entity instance.

 

MIB file name

hh3c-entity-ext.mib

Notifications

hh3cEntityExtTemperatureThresholdNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.1

Temperature of an entity exceeding the threshold

Error notification

Major

1.3.6.1.4.1.25506.2.6.2.0.22 (hh3cEntityExtTemperatureNormal)

ON

 

Notification triggers

This notification is generated when the temperature of an entity exceeds the upper limit.

System impact

Too high temperature affects normal operation of the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature)

Temperature of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.13 (hh3cEntityExtTemperatureThreshold)

Temperature threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

 

Recommended action

1.Verify that the temperature of the environment is normal. Execute the display environment command to obtain temperature information, including the current temperature and the temperature thresholds.

2.Identify the reason why the temperature exceeded the upper limit.

3.Verify that the temperature has dropped back to the normal.

4.If the issue persists, contact H3C Support.

hh3cEntityExtCpuUsageThresholdNotfication

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.4

CPU usage of an entity exceeding the threshold

Error notification

Major

1.3.6.1.4.1.25506.2.6.2.0.25 (hh3cEntityExtCpuUsageThresholdRecover)

ON

 

Notification triggers

This notification is generated when the CPU usage of an entity exceeds the threshold. The notification is sent every 60 seconds till the alarm is cleared.

System impact

The service processing capacity of the system will be reduced.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.6 (hh3cEntityExtCpuUsage)

CPU usage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.7 (hh3cEntityExtCpuUsageThreshold)

CPU usage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

1.3.6.1.4.1.25506.2.6.1.1.1.1.31 (hh3cEntityExtCpuUsageRecoverThreshold)

CPU usage recovery threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.2.1.4 (hh3cEntityExtFirstTrapTime)

Timestamp at which the notification is sent for the first time.

N/A

TimeTicks

Standard MIB values.

 

Recommended action

1.If the alarm is automatically cleared, no action is required.

2.If the alarm cannot be automatically cleared, contact H3C Support.

hh3cEntityExtMemUsageThresholdNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.5

Memory usage of an entity exceeding the threshold

Error notification

Major

1.3.6.1.4.1.25506.2.6.2.0.26 (hh3cEntityExtMemUsageThresholdRecover)

ON

 

Notification triggers

This notification is generated when the memory usage of an entity that has a total memory size less than 4 GB exceeds the threshold (hh3cEntityExtMemUsageThreshold). The notification is sent every 60 seconds till the alarm is cleared.

An hh3cEntityExtMemUsageThresholdOverTrap notification is generated when the memory usage of an entity that has a total memory size equal to or larger than 4 GB exceeds the threshold (hh3cEntityExtMemUsageThreshold).

System impact

The available memory size is reduced, which might affect the service processing capacity of the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.8 (hh3cEntityExtMemUsage)

Memory usage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.9 (hh3cEntityExtMemUsageThreshold)

Memory usage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.10 (hh3cEntityExtMemSize)

Memory size of the entity.

hh3cEntityExtPhysicalIndex

Unsigned32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

1.3.6.1.4.1.25506.2.6.2.1.4 (hh3cEntityExtFirstTrapTime)

Timestamp at which the notification is sent for the first time.

N/A

TimeTicks

Standard MIB values.

 

Recommended action

1.Delete unused services to reduce memory consumption.

2.If the alarm is automatically cleared, no action is required. If the alarm cannot be automatically cleared, contact H3C Support.

hh3cEntityExtCriticalTemperatureThresholdNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.8

Temperature of an entity exceeding the critical high-temperature threshold

Error notification

Critical

1.3.6.1.4.1.25506.2.6.2.0.22 (hh3cEntityExtTemperatureNormal)

ON

 

Notification triggers

This notification is generated when the temperature of an entity exceeded the critical high-temperature threshold. The notification is sent every 80 seconds till the alarm is cleared.

System impact

The high temperature affects normal operation of the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature)

Temperature of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.17 (hh3cEntityExtCriticalTemperatureThreshold)

Critical high-temperature threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

 

Recommended action

1.Verify that the temperature of the environment is normal. Execute the display environment command to obtain temperature information, including the current temperature and the temperature thresholds.

2.Identify the reason why the temperature exceeded the critical high-temperature threshold.

3.Verify that the temperature has dropped back to the normal.

4.If the issue persists, contact H3C Support.

hh3cEntityExtSFPAlarmOn

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.9

An error was detected on a transceiver module entity

Error

Major

1.3.6.1.4.1.25506.2.6.2.0.10 (hh3cEntityExtSFPAlarmOffEx)

ON

 

Notification triggers

This notification is generated when an error is detected on a transceiver module.

System impact

The transceiver module on which the error was detected is unavailable.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Entity admin status.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Entity alarm status.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

1.3.6.1.4.1.25506.2.6.1.1.1.1.19 (hh3cEntityExtErrorStatus)

Entity error status.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

1.Examine the transceiver module for errors.

2.If the issue persists, contact H3C Support.

hh3cEntityExtSFPAlarmOff

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.10

The error on the transceiver module entity was removed

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a transceiver module recovers.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Entity admin status.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Entity alarm status.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

1.3.6.1.4.1.25506.2.6.1.1.1.1.19 (hh3cEntityExtErrorStatus)

Entity error status.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

No action is required.

hh3cEntityInsert

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.12

Entity installation

Recovery notification

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when an entity is inserted into the device.

System impact

No negative impact on services.

Objects

Objects

OID (object name)

Description

Index nodes

Type

Value range

 

1.3.6.1.2.1.47.1.1.1.1.2 (entPhysicalDescr)

Description of the entity.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

 

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1)

locked(2)

shuttingDown(3)

unlocked(4)}

 

1.3.6.1.4.1.25506.2.6.1.1.1.1.3 (hh3cEntityExtOperStatus)

Operation status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cOperState

notSupported(1)

disabled(2)

enabled(3)

dangerous(4)

 

 

Recommended action

No action is required.

hh3cEntityRemove

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

 

1.3.6.1.4.1.25506.2.6.2.0.13

Entity removal

Error notification

Minor

1.3.6.1.4.1.25506.2.6.2.0.12(hh3cEntityInsert)

ON

 

 

Notification triggers

This notification is generated when an entity is removed from the device.

System impact

Depends on the removed entity.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.2.1.47.1.1.1.1.2 (entPhysicalDescr)

Description of the entity.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.3 (hh3cEntityExtOperStatus)

Operation status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cOperState

notSupported(1), disabled(2), enabled(3), dangerous(4)

 

Recommended action

1.If the entity was removed from the device, no action is required.

2.If the entity was not removed, verify that the entity is installed correctly.

3.If the issue persists, contact H3C Support.

hh3cEntityExtFaultAlarmOn

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.16

Error occurrence on an entity

Error notification

Major

1.3.6.1.4.1.25506.2.6.2.0.17 (hh3cEntityExtFaultAlarmOff)

ON

 

Notification triggers

This notification is generated when an error occurs on the entity.

System impact

The impact depends on the faulty entity.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.19 (hh3cEntityExtErrorStatus)

Entity error status.

hh3cEntityExtPhysicalIndex

INTEGER

notSupported(1), normal(2), postFailure(3), entityAbsent(4), poeError(11), stackError(21), stackPortBlocked(22), stackPortFailed(23), sfpRecvError(31), sfpSendError(32), sfpBothError(33), sfpRecvExceedUpperLimit(34),, sfpRecvBelowLowerLimit(35),, sfpSendExceedUpperLimit(36),, sfpSendBelowLowerLimit(37),, fanError(41), psuError(51), rpsError(61), moduleFaulty(71), sensorError(81), hardwareFaulty(91)

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

 

Recommended action

1.Verify that the entity is installed correctly.

2.If the issue persists, contact H3C Support.

hh3cEntityExtFaultAlarmOff

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.17

Error clearance

Recovery notification

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when an entity recovers from the faulty state.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.19 (hh3cEntityExtErrorStatus)

Error status of the entity.

hh3cEntityExtPhysicalIndex

INTEGER

notSupported(1), normal(2), postFailure(3), entityAbsent(4), poeError(11), stackError(21), stackPortBlocked(22), stackPortFailed(23), sfpRecvError(31), sfpSendError(32), sfpBothError(33), sfpRecvExceedUpperLimit(34),, sfpRecvBelowLowerLimit(35),, sfpSendExceedUpperLimit(36),, sfpSendBelowLowerLimit(37),, fanError(41), psuError(51), rpsError(61), moduleFaulty(71), sensorError(81), hardwareFaulty(91)

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

 

Recommended action

No action is required.

hh3cEntityExtTemperatureLower

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.20

Temperature of an entity lower than the low-temperature threshold

Error notification

Major

1.3.6.1.4.1.25506.2.6.2.0.22 (hh3cEntityExtTemperatureNormal)

ON

 

Notification triggers

This notification is generated when the temperature of an entity decreases below the low-temperature threshold.

System impact

A low temperature affects normal operation of the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature)

Temperature of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.21 (hh3cEntityExtLowerTemperatureThreshold)

Low-temperature threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

 

Recommended action

1.Verify that the temperature of the environment is normal. Execute the display environment command to obtain temperature information, including the current temperature and the temperature thresholds.

2.Identify the reason why the temperature dropped below the lower limit.

3.Verify that the temperature has increased to the normal.

4.If the issue persists, contact H3C Support.

hh3cEntityExtTemperatureTooUp

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.21

Temperature of an entity exceeded the shutdown temperature threshold

Error

Critical

1.3.6.1.4.1.25506.2.6.2.0.22 (hh3cEntityExtTemperatureNormal)

ON

 

Notification triggers

This notification is generated when the temperature of an entity exceeds the shutdown temperature threshold. The notification is sent every 80 seconds till the alarm is cleared.

System impact

Too high temperature causes the system to shut down right now or anytime.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature)

Temperature of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.22 (hh3cEntityExtShutdownTemperatureThreshold)

Shutdown temperature threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

 

Recommended action

1.Verify that the temperature of the environment is normal. Execute the display environment command to obtain temperature information, including the current temperature and the temperature thresholds.

2.Identify the reason causing the temperature to exceed the shutdown temperature threshold.

3.Resolve the issue to make sure the temperature drops back to the normal range.

4.If the issue persists, contact H3C Support.

hh3cEntityExtTemperatureNormal

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.22

Temperature of an entity returned to the normal range.

Recovery notification

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the temperature of an entity returns to the normal range.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature)

Temperature of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.21 (hh3cEntityExtLowerTemperatureThreshold)

Low-temperature threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.13 (hh3cEntityExtTemperatureThreshold)

Temperature threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

 

Recommended action

No action is required.

hh3cEntityExternalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.23

Entity peripheral fault.

Error

Major

1.3.6.1.4.1.25506.2.6.2.0.24 (hh3cEntityExternalAlarmRecover)

ON

 

Notification triggers

This notification is generated when an error occurs on the peripheral of an entity.

System impact

Depends on the faulty entity.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Verify that the entity is installed correctly.

2.If the issue persists, contact H3C Support.

hh3cEntityExternalAlarmRecover

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.24

A peripheral of an entity recovered.

Recovery notification

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the peripheral of an entity recovers from the faulty state.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtCpuUsageThresholdRecover

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.25

CPU usage of an entity restored to the normal range.

Recovery notification

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the CPU usage of an entity restores to the normal range.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.6 (hh3cEntityExtCpuUsage)

CPU usage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.7 (hh3cEntityExtCpuUsageThreshold)

CPU usage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

1.3.6.1.4.1.25506.2.6.1.1.1.1.31 (hh3cEntityExtCpuUsageRecoverThreshold)

CPU usage recovery threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.2.1.4 (hh3cEntityExtFirstTrapTime)

Timestamp at which the notification is sent for the first time.

N/A

TimeTicks

Standard MIB values.

 

Recommended action

No action is required.

hh3cEntityExtMemUsageThresholdRecover

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.26

Memory usage of an entity restored to the normal range.

Recovery notification

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the memory usage of an entity restores to the normal range.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.8 (hh3cEntityExtMemUsage)

Memory usage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.9 (hh3cEntityExtMemUsageThreshold)

Memory usage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.10 (hh3cEntityExtMemSize)

Memory size of the entity.

hh3cEntityExtPhysicalIndex

Unsigned32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

1.3.6.1.4.1.25506.2.6.2.1.4 (hh3cEntityExtFirstTrapTime)

Timestamp at which the notification is sent for the first time.

N/A

TimeTicks

Standard MIB values.

 

Recommended action

No action is required.

hh3cEntityExtMemAllocatedFailed

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.27

Memory allocation request failure

Informational

Major

N/A (N/A)

ON

 

Notification triggers

This notification is generated when memory allocation for the entity failed.

System impact

An incorrect memory allocation affects system services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.2.1.1 (hh3cEntityExtTrapDescription)

Description of the notification.

N/A

SnmpAdminString

OCTET STRING (SIZE (0..255))

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtECCParityAlarm

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.28

ECC parity check error

Informational

Major

-

ON

 

Notification triggers

This notification is generated when an ECC parity check error occurs on an entity.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.2.1.2 (hh3cEntityExtECCParityAlarmStatus)

Status of ECC parity check for the entity

N/A

INTEGER

other(1), l1cache(2), l2cache(3), sdram(4), mac(5), tcam(6), ingressbuffer(7), egressbuffer(8), lpm(9), controlmemory(10)

1.3.6.1.4.1.25506.2.6.2.1.1 (hh3cEntityExtTrapDescription)

Description of the entity.

N/A

SnmpAdminString

OCTET STRING (SIZE (0..255))

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtFanDirectionNotPreferred

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.31

The airflow direction of a fan tray is different from the preferred airflow direction.

Error

Major

1.3.6.1.4.1.25506.8.35.12.1.7 (hh3cFanNormal)

ON

 

Notification triggers

This notification is generated when the airflow direction of a fan tray is different from the preferred airflow direction. The possible reasons include the following:

The preferred airflow direction configuration is incorrect.

An incorrect fan tray is inserted.

System impact

Incorrect airflow direction of a fan tray will affect the system heat dissipation.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Select a fan tray according to the ventilation system in the equipment room. A fan tray can operate effectively only when it uses the same airflow direction as the ventilation system in the equipment room.

2.If the fan tray uses the same airflow direction as the ventilation system in the equipment room, verify that the configured preferred airflow direction is the same as the airflow direction of the fan tray.

hh3cEntityExtMemUsageThresholdOverTrap

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.35

Memory usage exceeded the threshold.

Error

Major

1.3.6.1.4.1.25506.2.6.2.0.36 (hh3cEntityExtMemUsageThresholdRecoverTrap)

ON

 

Notification triggers

This notification is generated when the total memory size of the entity is equal to or greater than 4 GB and the memory usage of the entity exceeds hh3cEntityExtMemUsageThreshold (memory usage threshold). The notification is sent every 60 seconds till the alarm is cleared.

If the total memory size is less than 4 GB, an hh3cEntityExtMemUsageThresholdNotification notification is generated when the memory usage exceeds hh3cEntityExtMemUsageThreshold.

System impact

Decreased available memory size might reduce the service processing capacity of the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.8 (hh3cEntityExtMemUsage)

Memory usage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.9 (hh3cEntityExtMemUsageThreshold)

Memory usage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

1.3.6.1.4.1.25506.2.6.1.1.1.1.32 (hh3cEntityExtMemSizeRev)

Memory size of the entity.

hh3cEntityExtPhysicalIndex

Counter64

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

 

Recommended action

1.Disable unused services to reduce memory consumption.

2.If the alarm is automatically cleared, no action is required. If the alarm cannot be automatically cleared, contact H3C Support.

hh3cEntityExtMemUsageThresholdRecoverTrap

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.36

Memory usage of an entity restored to the normal range.

Recovery notification

Warning

-

ON

 

Notification triggers

This notification is generated when the memory usage of an entity recovers restores to the normal range.

Status control

This notification cannot be disabled.

Objects

OID (object name)

Description

Index nodes

Type

Value range

 

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

1.3.6.1.4.1.25506.2.6.1.1.1.1.8 (hh3cEntityExtMemUsage)

Memory usage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

 

1.3.6.1.4.1.25506.2.6.1.1.1.1.9 (hh3cEntityExtMemUsageThreshold)

Memory usage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

0..100

 

1.3.6.1.4.1.25506.2.6.1.1.1.1.32 (hh3cEntityExtMemSizeRev)

Memory size of the entity.

hh3cEntityExtPhysicalIndex

Counter64

Standard MIB values.

 

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1)

locked(2)

shuttingDown(3)

unlocked(4)}

 

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {

notSupported(0)

underRepair(1)

critical(2)

major(3)

minor(4)

alarmOutstanding(5)

warning(6)

indeterminate(7)

}

 

 

Recommended action

No action is required.

hh3cEntityExtVoltageNormal

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

 

1.3.6.1.4.1.25506.2.6.2.0.37

Voltage of an entity restored to the normal range

Recovery notification

Warning

N/A

ON

 

 

Notification triggers

This notification is generated when the voltage of an entity restores to the normal range.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage)

Voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.2 (hh3cEntityExtNominalVoltage)

Rated voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.4 (hh3cEntityExtVoltageMajorLowThreshold)

Low-voltage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.6 (hh3cEntityExtVoltageMajorHighThreshold)

High-voltage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

No action is required.

hh3cEntityExtVoltageLower

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.38

Voltage of an entity dropped below the low-voltage threshold

Error

Major

1.3.6.1.4.1.25506.2.6.2.0.37 (hh3cEntityExtVoltageNormal)

ON

 

Notification triggers

This notification is generated when the voltage of an entity drops below the low-voltage threshold.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage)

Voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.2 (hh3cEntityExtNominalVoltage)

Rated voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.4 (hh3cEntityExtVoltageMajorLowThreshold)

Low-voltage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

1.Verify that the power system of the device is normal.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageTooLow

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.39

Voltage of the threshold dropped below critical low-voltage threshold

Error

Critical

1.3.6.1.4.1.25506.2.6.2.0.37 (hh3cEntityExtVoltageNormal)

ON

 

Notification triggers

This notification is generated when the voltage of the entity drops below the critical low-voltage threshold. The notification is sent every 80 seconds till the alarm is cleared.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage)

Voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.2 (hh3cEntityExtNominalVoltage)

Rated voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.5 (hh3cEntityExtVoltageFatalLowThreshold)

Critical low-voltage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

1.Verify that the power system of the device is normal.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageHigher

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.40

Voltage of an entity exceeded the high-voltage threshold

Error

Major

1.3.6.1.4.1.25506.2.6.2.0.37 (hh3cEntityExtVoltageNormal)

ON

 

Notification triggers

This notification is generated when the voltage of an entity increases above the high-voltage threshold.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage)

Voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.2 (hh3cEntityExtNominalVoltage)

Rated voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.6 (hh3cEntityExtVoltageMajorHighThreshold)

High-voltage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

1.Verify that the power system of the device is normal.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageTooHigh

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.41

Voltage of an entity exceeded the critical high-voltage threshold

Error

Critical

1.3.6.1.4.1.25506.2.6.2.0.37 (hh3cEntityExtVoltageNormal)

ON

 

Notification triggers

This notification is generated when the voltage of an entity increases over the critical high-voltage threshold. The notification is sent every 80 seconds till the alarm is cleared.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage)

Voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.2 (hh3cEntityExtNominalVoltage)

Rated voltage of the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.1.5.1.1.7 (hh3cEntityExtVoltageFatalHighThreshold)

Critical high-voltage threshold for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

1.Verify that the power system of the device is normal.

2.If the issue persists, contact H3C Support.

hh3cEntityExtSFPAlarmOnEx

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.42

Failure of a transceiver module.

Error

Major

1.3.6.1.4.1.25506.2.6.2.0.43 (hh3cEntityExtSFPAlarmOffEx)

ON

 

Notification triggers

This notification is generated when a transceiver module is faulty.

System impact

The faulty transceiver module is not available for use.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

1.3.6.1.4.1.25506.2.6.1.1.1.1.19 (hh3cEntityExtErrorStatus)

Alarm status for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

1.Verify that the transceiver module is normal.

2.If the issue persists, contact H3C Support.

hh3cEntityExtSFPAlarmOffEx

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.43

Recovery of a transceiver module.

Recovery notification

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a transceiver module recovers from a fault.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

1.3.6.1.4.1.25506.2.6.1.1.1.1.19 (hh3cEntityExtErrorStatus)

Alarm status for the entity.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

 

Recommended action

No action is required.

h3cEntityExtSFPPhony

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.2.0.11

A counterfeit transceiver module was detected.

Error

Major

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a counterfeit transceiver module is detected.

System impact

Use of a counterfeit transceiver module might result in communication failure.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus)

Administrative status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAdminState

notSupported(1), locked(2), shuttingDown(3), unlocked(4)}

1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight)

Alarm status of the entity.

hh3cEntityExtPhysicalIndex

Hh3cAlarmStatus

BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), }

 

Recommended action

To resolve this issue, replace the counterfeit transceiver module with one from H3C.

hh3cEntityExtSystemFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.1

System critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.2 (hh3cEntityExtSystemFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a system critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the system status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtSystemFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.2

System critical alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a system critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtSystemAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.3

System major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.4 (hh3cEntityExtSystemAlarmClear)

ON

 

Notification triggers

This notification is generated when a system major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the system status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtSystemAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.4

System major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a system major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtSystemWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.5

System warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.6 (hh3cEntityExtSystemWarningClear)

ON

 

Notification triggers

This notification is generated when a system warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the system status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtSystemWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.6

System warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a system warning alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

Board major alarm occurred

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a board major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the board status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

Board major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a board major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

Board major alarm occurred

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated a board major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the board status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

Board major alarm cleared

Recovery

N/A

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a board major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

Board warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when a board warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the board status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

Board warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a board warning alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtPowerFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.13

Power supply critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.14 (hh3cEntityExtPowerFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a power supply critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the power supply status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtPowerFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.14

Power supply critical alarm cleared

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a power supply critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtPowerAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.15

Power supply major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.16 (hh3cEntityExtPowerAlarmClear)

ON

 

Notification triggers

This notification is generated when a power supply major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the power status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtPowerAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.16

Power supply major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a power supply major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtPowerWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.17

Power supply warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.18 (hh3cEntityExtPowerWarningClear)

ON

 

Notification triggers

This notification is generated when a power supply waring alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the power status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtPowerWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.18

Power supply waring alarm cleared

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a power supply waring alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtFanFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.19

Fan tray critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.20 (hh3cEntityExtFanFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a fan tray critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the fan tray status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtFanFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.20

Fan tray critical alarm cleared.

Recovery

N/A

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a fan tray critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtFanAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.21

Fan tray major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.22 (hh3cEntityExtFanAlarmClear)

ON

 

Notification triggers

This notification is generated when a fan tray major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the fan tray status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtFanAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.22

Fan tray major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a fan tray major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtFanWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.23

Fan tray warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.24 (hh3cEntityExtFanWarningClear)

ON

 

Notification triggers

This notification is generated when a fan tray warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the fan tray status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtFanWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.24

Fan tray warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a fan tray waring alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtVoltageFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.25

Voltage critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.26 (hh3cEntityExtVoltageFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a voltage critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

1.Check voltage information and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.26

Voltage critical alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a voltage critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.27

Voltage major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.28 (hh3cEntityExtVoltageAlarmClear)

ON

 

Notification triggers

This notification is generated when a voltage major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

1.Check voltage information and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.2

Voltage major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a voltage major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

Voltage warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when a voltage warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

1.Check voltage information and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

Voltage warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a voltage warning alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtTemperatureFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.31

Temperature critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.32 (hh3cEntityExtTemperatureFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a temperature critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

1.Check temperature information and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtTemperatureFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.32

Temperature critical alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a temperature critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63)

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtTemperatureAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.33

Temperature major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.34 (hh3cEntityExtTemperatureAlarmClear)

ON

 

Notification triggers

This notification is generated when a temperature major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

1.Check temperature information and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtTemperatureAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.34

Temperature major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a temperature major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtTemperatureWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.35

Temperature warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.36 (hh3cEntityExtTemperatureWarningClear)

ON

 

Notification triggers

This notification is generated when a temperature warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

1.Check temperature information and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtTemperatureWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.36

Temperature warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a temperature warning alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.4 (hh3cEntityExtThresholdType)

Threshold type.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.5 (hh3cEntityExtThresholdVal)

Threshold value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1.6 (hh3cEntityExtCurrentVal)

Current value.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtClockFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.37

Clock critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.38 (hh3cEntityExtClockFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a clock critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the clock status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtClockFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.38

Clock critical alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a clock critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtClockAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.39

Clock major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.40 (hh3cEntityExtClockAlarmClear)

ON

 

Notification triggers

This notification is generated when a clock major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the clock status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtClockAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.40

Clock major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a clock major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtClockWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.41

Clock warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.42 (hh3cEntityExtClockWarningClear)

ON

 

Notification triggers

This notification is generated when a clock warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the clock status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtClockWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.42

Clock warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a clock warning alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtDiskFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.43

Disk critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.44 (hh3cEntityExtDiskFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a disk critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the disk status and resolve the issue,

2.If the issue persists, contact H3C Support.

hh3cEntityExtDiskFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.44

Disk critical alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a disk critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtDiskAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.45

Disk major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.46 (hh3cEntityExtDiskAlarmClear)

ON

 

Notification triggers

This notification is generated when a disk major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the disk status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtDiskAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.46

Disk major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a disk major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtDiskWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.47

Disk warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.48 (hh3cEntityExtDiskWarningClear)

ON

 

Notification triggers

This notification is generated when a disk warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check disk status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtDiskWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.48

Disk warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a disk warning alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtOpticalFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.49

Transceiver critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.50 (hh3cEntityExtOpticalFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a transceiver critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the transceiver status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtOpticalFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.50

Transceiver critical alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a transceiver critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtOpticalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.51

Transceiver major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.52 (hh3cEntityExtOpticalAlarmClear)

ON

 

Notification triggers

This notification is generated when a transceiver major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the transceiver status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtOpticalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.52

Transceiver major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a transceiver major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtOpticalWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.53

Transceiver warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.54 (hh3cEntityExtOpticalWarningClear)

ON

 

Notification triggers

This notification is generated when a transceiver warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the transceiver status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtOpticalWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.54

Transceiver warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a transceiver warning alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkFatalAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.55

Internal link critical alarm occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.56 (hh3cEntityExtInternalLinkFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when an internal link critical alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the internal link status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkFatalAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.56

Internal link critical alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when an internal link critical alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkAlarmOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.57

Internal link major alarm occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.58 (hh3cEntityExtInternalLinkAlarmClear)

ON

 

Notification triggers

This notification is generated when an internal link major alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the internal link status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkAlarmClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.58

Internal link major alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when an internal link major alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkWarningOccur

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.59

Internal link warning alarm occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.60 (hh3cEntityExtInternalLinkWarningClear)

ON

 

Notification triggers

This notification is generated when an internal link warning alarm occurs.

System impact

The service processing capacity of the system might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

1.Check the internal link status and resolve the issue.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkWarningClear

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.60

Internal link warning alarm cleared.

Recovery

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when an internal link warning alarm is cleared.

System impact

No negative impact on services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

hh3cEntityExtPhysicalIndex

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

entPhysicalIndex

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.1 (hh3cEntityExtRelativeResource)

Location information of the entity.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1.2 (hh3cEntityExtErrorCode)

Error code.

N/A

Integer32

Standard MIB values.

1.3.6.1.4.1.25506.2.6.4.1.3 (hh3cEntityExtReason)

Failure reason description.

N/A

OCTECT STRING

OCTET STRING (SIZE (0..255))

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10433003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when access to a temperature sensor fails. (hh3cEntityExtErrorCode=10433003): $1 temperature chip became faulty.

System impact

A temperature anomaly is present on the device.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check temperature information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10433003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the temperature sensor access failure is fixed. (hh3cEntityExtErrorCode=10433003): $1 temperature chip restored to normal.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtTemperatureAlarmOccur(hh3cEntityExtErrorCode=10433004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.33

A major temperature fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.34 (hh3cEntityExtTemperatureAlarmClear)

ON

 

Notification triggers

This notification is generated when the temperature reading of a sensor goes out of range. (hh3cEntityExtErrorCode=10433004): $1 temperature out of range.

System impact

A temperature anomaly is present on the device.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check temperature information and take actions to resolve any identified issues.

2.If the issue persists, contact H3C Support.

hh3cEntityExtTemperatureAlarmClear(hh3cEntityExtErrorCode=10433004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.34

A major temperature fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a temperature out of range issue is cleared. (hh3cEntityExtErrorCode=10433004): $1 temperature out of range issue removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtFanAlarmOccur(hh3cEntityExtErrorCode=10300001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.21

A major fan tray fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.22 (hh3cEntityExtFanAlarmClear)

ON

 

Notification triggers

This notification is generated when a fan tray fails. (hh3cEntityExtErrorCode=10300001): Fan tray %s failed.

System impact

A fan tray anomaly is present on the device.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the fan tray status and take actions to resolve any identified issues.

2.If the issue persists, contact H3C Support.

hh3cEntityExtFanAlarmClear(hh3cEntityExtErrorCode=10300001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.22

A major fan tray fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a fan tray recovers from a failure. (hh3cEntityExtErrorCode=10300001): Fan tray $1 recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtFanAlarmOccur(hh3cEntityExtErrorCode=10300002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.21

A major fan tray fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.22 (hh3cEntityExtFanAlarmClear)

ON

 

Notification triggers

This notification is generated when the speed of a fan tray falls below the lower speed threshold. (hh3cEntityExtErrorCode=10300002): Fan $1 speed fell below the lower speed threshold.

System impact

A fan tray anomaly is present on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the fan tray status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtFanAlarmClear(hh3cEntityExtErrorCode=10300002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.22

A major fan tray fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the speed of a fan tray increases to the normal range. (hh3cEntityExtErrorCode=10300002): Fan $1 speed increased to the normal range.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtFanAlarmOccur(hh3cEntityExtErrorCode=10300008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.21

A major fan tray fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.22 (hh3cEntityExtFanAlarmClear)

ON

 

Notification triggers

This notification is generated when the speed of a fan tray falls below the configured speed. (hh3cEntityExtErrorCode=10300008): Fan speed deviated largely from the configured value: Actual speed = $1 RPM, Configured speed = $2 RPM.

System impact

A fan tray anomaly is present on the device.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the fan tray status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtFanAlarmClear(hh3cEntityExtErrorCode=10300008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.22

A major fan tray fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the speed of a fan tray increase to the configured speed. (hh3cEntityExtErrorCode=10300008): Fan speed calibrated with the configured value: Actual speed = $1 RPM, Configured speed = $2 RPM.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtFanAlarmOccur(hh3cEntityExtErrorCode=20300008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.21

A major fan tray fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.22 (hh3cEntityExtFanAlarmClear)

ON

 

Notification triggers

This notification is generated when the speed of a fan tray exceeds the configured speed. (hh3cEntityExtErrorCode=20300008): Fan speed deviated largely from the configured value: Actual speed = $1 RPM, Configured speed = $2 RPM.

System impact

A fan tray anomaly is present on the device.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the status of the fan tray and take actions to resolve any identified issues.

2.If the issue persists, contact H3C Support for help.

hh3cEntityExtFanAlarmClear(hh3cEntityExtErrorCode=20300008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.22

A major fan tray fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the speed of a fan tray drops to the configured speed. (hh3cEntityExtErrorCode=20300008): Fan speed calibrated with the configured value: Actual speed = $1 RPM, Configured speed = $2 RPM.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=30441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the fan tray EEPROM fails. (hh3cEntityExtErrorCode=30441001): EEPROM read/write failed.

System impact

Fan tray manufacturing information cannot be retrieved.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=30441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write to the fan tray EEPROM. (hh3cEntityExtErrorCode=30441001):EEPROM read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=10200012)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.15

A major power fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.15 (hh3cEntityExtPowerAlarmClear)

ON

 

Notification triggers

This notification is generated when no sufficient power is present to power on a card. (hh3cEntityExtErrorCode=10200012): No enough power to power on the board in chassis $1 slot $2. Required power is $3 W, available power is $4 W.

System impact

The card cannot start.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, replace the power supplies with high-power ones.

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=10200012)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.16

A major power fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the insufficient power issue is cleared. (hh3cEntityExtErrorCode=10200012): Chassis $1 recovered from insufficient power capacity.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=10200011)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.15

A major power fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.15 (hh3cEntityExtPowerAlarmClear)

ON

 

Notification triggers

This notification is generated when redundant power is detected insufficient. (hh3cEntityExtErrorCode=10200011): Power redundancy in chassis $1 failed. Required redundant power is$2 W, redundant power is $3 W.

System impact

The cards might be powered off.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, replace the power supplies with high-power ones.

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=10200011)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.16

A major power fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the insufficient redundant power issue is cleared. (hh3cEntityExtErrorCode=10200011): Chassis $1 recovered from power redundancy failure.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=10200024)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.15

A major power fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.15 (hh3cEntityExtPowerAlarmClear)

ON

 

Notification triggers

This notification is generated when power supplies of different models are installed on the same device. (hh3cEntityExtErrorCode=10200024): Inconsistent power supply models.

System impact

Power supply failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, install power supplies of the same model on the device.

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=10200024)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.16

A major power fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the power supply model inconsistency issue is cleared. (hh3cEntityExtErrorCode=10200024): Power supply model inconsistency issue removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=10200003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.15

A major power fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.15 (hh3cEntityExtPowerAlarmClear)

ON

 

Notification triggers

This notification is generated when an unknown power supply is detected. (hh3cEntityExtErrorCode=10200003): Unknown power supply $1.

System impact

A power supply anomaly is present on the device.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=10200003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.16

A major power fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the unknown power supply issue is cleared. (hh3cEntityExtErrorCode=10200003):Unknown power supply $1 error removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the power supply EEPROM fails. (hh3cEntityExtErrorCode=40441001):EEPROM read/write failed.

System impact

Power supply manufacturing information cannot be retrieved.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=40441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restored read/write to the power supply EEPROM. (hh3cEntityExtErrorCode=40441001):EEPROM read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=10400006)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a card is powered off because of overtemperature. (hh3cEntityExtErrorCode=10400006):The card in slot $1 was powered off because the temperature exceeded the high temperature shutdown threshold.

System impact

The temperature of the device is too high and the cards are powered off.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, check the ambient temperature in the equipment room and fan tray status and take actions to resolve any issues identified.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=10400006)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the temperature of a card drops to the normal range. (hh3cEntityExtErrorCode=10400006): The temperature of the card in slot $1 restored.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=10400004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when the standby MPU fails registration with the system because its main OEM is inconsistent with that of the active MPU. (hh3cEntityExtErrorCode=10400004): Card in slot $1 failed to register with the system.

System impact

The standby MPU cannot startup correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=10400004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the main OEM inconsistency between the standby and the active MPU is cleared and the standby MPU registers with the system successfully. (hh3cEntityExtErrorCode=10400004): Card in slot $1 registered with the system successfully.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=20400004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when a service module fails to register with the system because its main OEM is consistent with that of the active MPU. (hh3cEntityExtErrorCode=20400004): Card in slot $1 failed to register with the system.

System impact

The service module fails to start up correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=20400004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the main OEM inconsistency between an interface module and the active MPU is cleared and the interface module registers with the system successfully. (hh3cEntityExtErrorCode=20400004): Card in slot $1 registered with the system successfully.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=30400004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when a card fails to register with the system because the card is incompatible with the device.(hh3cEntityExtErrorCode=30400004): Card in slot $1 failed to register with the system.

System impact

The card fails to start up correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, install the card on a device with which it is compatible.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=30400004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when incompatibility of a card with the device is cleared and the card registers with the system successfully. (hh3cEntityExtErrorCode=30400004): Card in slot $1 registered with the system successfully.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtSystemWarningOccur(hh3cEntityExtErrorCode=10100005)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.5

A system warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.6 (hh3cEntityExtSystemWarningClear)

ON

 

Notification triggers

This notification is generated when the type of a card is detected inconsistent with the preconfigured type. (hh3cEntityExtErrorCode=10100005): Board type inconsistent with the preconfigured type.

System impact

The card fails to start up correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, replace the card with one of the preconfigured type.

hh3cEntityExtSystemWarningClear(hh3cEntityExtErrorCode=10100005)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.6

A system warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when inconsistency of a card type with the preconfigure type is cleared. (hh3cEntityExtErrorCode=10100005): Board type consistent with the preconfigured type.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=10429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the base card CPLD on the MPU fails. (hh3cEntityExtErrorCode=10429001): CPLD register read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=10429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write to the base card CPLD on the MPU. (hh3cEntityExtErrorCode=10429001): CPLD register read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=20429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the daughter card CPLD on the MPU fails. (hh3cEntityExtErrorCode=20429001): CPLD register read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=20429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write to the daughter card CPLD on the MPU. (hh3cEntityExtErrorCode=20429001): CPLD register read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=50429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the base card CPLD on a service module fails. (hh3cEntityExtErrorCode=50429001): CPLD register read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=50429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write to the based card CPLD on a service module. (hh3cEntityExtErrorCode=50429001): CPLD register read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=60429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the daughter card CPLD on a service module fails. (hh3cEntityExtErrorCode=60429001): CPLD register read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=60429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write to the daughter card CPLD on a service module. (hh3cEntityExtErrorCode=60429001): CPLD register read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10420001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when access to a power monitoring chip on a card fails (hh3cEntityExtErrorCode=10420001): Failed to access voltage chip channel $1 on $2 chip $3.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10420001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores access to a power monitoring chip on a card. (hh3cEntityExtErrorCode=10420001): Restored access to voltage chip channel $1 on $2 chip $3.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10430001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when access to the RTC fails. (hh3cEntityExtErrorCode=10430001): RTC read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10430001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restore the access to the RTC chip. (hh3cEntityExtErrorCode=10430001): RTC read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10430002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when the RTC voltage is detected low. (hh3cEntityExtErrorCode=10430002): RTC voltage low.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10430002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the RTC voltage of a card restores to the normal range. (hh3cEntityExtErrorCode=10430002): RTC voltage increased to the acceptable range.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred..

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the card EEPROM fails. (hh3cEntityExtErrorCode=10441001): EEPROM read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores access to the card EEPROM. (hh3cEntityExtErrorCode=10441001): EEPROM read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=60440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when an FPGA SEU error occurs on a card. (hh3cEntityExtErrorCode=60440009): FPGA SEU error.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=60440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA SEU error is removed from a card. (hh3cEntityExtErrorCode=60440009): FPGA SEU error removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10443001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the EMMC fails. (hh3cEntityExtErrorCode=10443001): EMMC read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10443001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores access to the EMMC. (hh3cEntityExtErrorCode=10443001): EMMC read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtClockAlarmOccur(hh3cEntityExtErrorCode=100432022)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.39

A major clock fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.40 (hh3cEntityExtClockAlarmClear)

ON

 

Notification triggers

This notification is generated when the clock PLL chip goes out of lock. (hh3cEntityExtErrorCode=100432022): Clock PLL chip unlocked.

System impact

The clock status is abnormal.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the clock status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtClockAlarmClear(hh3cEntityExtErrorCode=100432022)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.40

A major clock fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the clock PLL chip restores to the locked status. (hh3cEntityExtErrorCode=100432022): Clock PLL chip locked.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10440016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when access to the FPGA custom bus fails. (hh3cEntityExtErrorCode=10440016): Failed to access the FPGA custom bus.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10440016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores access to the FPGA custom bus. (hh3cEntityExtErrorCode=10440016): Restored access to the FPGA custom bus.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtSystemWarningOccur(hh3cEntityExtErrorCode=10482009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.5

A system warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.6 (hh3cEntityExtSystemWarningClear)

ON

 

Notification triggers

This notification is generated when an active/standby management interface switchover occurs. (hh3cEntityExtErrorCode=1010482009): The active management interface port went down, and the standby management interface port took over.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the original active management interface and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtSystemWarningClear(hh3cEntityExtErrorCode=1010482009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.6

A system warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the original management interface takes back the active role. (hh3cEntityExtErrorCode=1010482009): The original management interface port came up and assumed the active role.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the chassis EEPROM fails. (hh3cEntityExtErrorCode=50441001): EEPROM read/write failed.

System impact

The chassis manufacturing information cannot be retrieved.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=50441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write to the chassis EEPROM. (hh3cEntityExtErrorCode=50441001): EEPROM read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=10420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP1 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=10420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=20420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP2 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=20420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=20420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP2 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=20420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=30420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP3 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=30420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=30420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP3 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=30420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=40420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP4 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=40420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=40420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP4 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=40420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=50420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VH on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=50420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=50420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VH on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=50420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=60420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX1 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=60420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=60420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX1 on a card increase above the low output voltage warning threshold. (hh3cEntityExtErrorCode=60420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=70420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX2 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=70420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=70420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX2 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=70420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=80420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX3 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=80420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=80420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX3 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=80420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=90420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX4 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=90420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=90420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX4 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=90420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=100420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX5 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=100420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=100420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX5 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=100420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=110420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin AUX1 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=110420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=110420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin AUX1 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=110420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=120420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin AUX2 on a card falls below the low output voltage warning threshold. (hh3cEntityExtErrorCode=120420002): Voltage on voltage chip channel $1 ($2) on the card $3 lower than the low output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=120420002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin AUX2 on a card increases above the low output voltage warning threshold. (hh3cEntityExtErrorCode=120420002): Voltage on voltage chip channel $1 ($2) on the card $3 increased above the low output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=10420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP1 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=10420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=10420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP1 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=10420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=20420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP2 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=20420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=20420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP2 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=20420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=30420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP3 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=30420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=30420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP3 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=30420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=40420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP4 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=40420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=40420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VP4 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=40420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=50420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VH on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=50420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=50420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VH on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=50420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=60420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX1 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=60420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=60420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX1 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=60420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=70420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX2 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=70420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=70420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX2 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=70420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=80420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX3 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=80420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=80420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX3 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=80420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=90420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX4 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=90420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=90420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX4 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=90420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=100420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX5 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=100420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=100420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin VX5 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=100420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=110420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin AUX1 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=110420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=110420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin AUX1 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=110420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtVoltageWarningOccur(hh3cEntityExtErrorCode=120420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.29

A voltage warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin AUX2 on a card exceeds the high output voltage warning threshold. (hh3cEntityExtErrorCode=120420004): Voltage on voltage chip channel $1 ($2) on the card $3 exceeded the high output voltage warning threshold.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

To resolve the issue:

1.Check voltage information and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtVoltageWarningClear(hh3cEntityExtErrorCode=120420004)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.30

A voltage warning was cleared

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the output voltage of the voltage pin AUX2 on a card falls below the high output voltage warning threshold. (hh3cEntityExtErrorCode=120420004): Voltage on voltage chip channel $1 ($2) on the card $3 fell below the high output voltage warning threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType)

Threshold type.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal)

Threshold value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal)

Current value.

N

OCTECT STRING

OCTET STRING (SIZE (0..63))

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=10100007

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when an unsupported subcard is installed in a slot on a card. (hh3cEntityExtErrorCode=10100007): Subcard not supported in the specified slot on the card.

System impact

The subcard cannot start up correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, replace the subcard with one supported by the slot.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=10100007

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when subcard incompatibility with the slot is cleared. (hh3cEntityExtErrorCode=10100007): Subcard supported in the specified slot on the card.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtSystemWarningOccur(hh3cEntityExtErrorCode=20100005)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.5

A system warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.6 (hh3cEntityExtSystemWarningClear)

ON

 

Notification triggers

This notification is generated when a subcard type is detected inconsistent with the preconfigured type. (hh3cEntityExtErrorCode=20100005): Board type inconsistent with the preconfigured type.

System impact

The subcard cannot start up correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Replace the subcard with one consistent with the preconfigured model

hh3cEntityExtSystemWarningClear(hh3cEntityExtErrorCode=10100006)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.6

A system warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the model of the newly installed subcard is consistent with that of the original subcard. (hh3cEntityExtErrorCode=10100006): Current subcard model consistent with the previous subcard model.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10540001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when FPGA loading on a subcard fails. (hh3cEntityExtErrorCode=10540001): FPGA on subcard loading failed.

System impact

The subcard cannot start up correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Replace the faulty subcard.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10540001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA loading failure on a subcard is cleared. (hh3cEntityExtErrorCode=10540001): FPGA on subcard loading failure resolved.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20420001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when access to a voltage monitoring chip on a subcard fails. (hh3cEntityExtErrorCode=20420001): Failed to access voltage chip channel $1 on $2 chip $3.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20420001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores access to a voltage monitoring chip on a subcard (hh3cEntityExtErrorCode=20420001): Restored access to voltage chip channel $1 on $2 chip $3.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=70429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the CPLD on a subcard fails. (hh3cEntityExtErrorCode=70429001): CPLD register read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Contact H3C Support.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=70429001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write to the CPLD on a subcard (hh3cEntityExtErrorCode=70429001): CPLD register read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write to the EEPROM on a subcard fails. (hh3cEntityExtErrorCode=20441001): EEPROM read/write failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20441001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write to the EEPROM on a subcard. (hh3cEntityExtErrorCode=20441001): EEPROM read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10400005)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when a subcard fails to power on. (hh3cEntityExtErrorCode=10400005): Board failed to power up.

System impact

The subcard cannot start up correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Replace the faulty subcard.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10400005)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a subcard powers on successfully after a power-on failure. (hh3cEntityExtErrorCode=10400005): Board powered up.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtPowerAlarmOccur(hh3cEntityExtErrorCode=20200012)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.15

A major power fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.15 (hh3cEntityExtPowerAlarmClear)

ON

 

Notification triggers

This notification is generated when a subcard fails to power on because of power insufficiency. (hh3cEntityExtErrorCode=20200012): No enough power to power on the board in chassis $1 slot $2. Required power is $3 W, available power is $4 W.

System impact

The subcard cannot start up correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Replace the power supplies with high-power ones.

hh3cEntityExtPowerAlarmClear(hh3cEntityExtErrorCode=20200012)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.16

A major power fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a subcard powers on successfully after the power becomes sufficient. (hh3cEntityExtErrorCode=20200012): Chassis $1 recovered from insufficient power capacity.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0474003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.55

A critical internal link fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.56 (hh3cEntityExtInternalLinkFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when an IPC link is detected abnormal. (hh3cEntityExtErrorCode=0474003): Failed to receive or send packets over the link $1. Source port = $2, Destination port =$3.

System impact

Service flapping might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0474003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.56

A critical internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the IPC link anomaly is cleared.(hh3cEntityExtErrorCode=0474003): Recovered packet receiving or sending over the link $1. Source port = $2, Destination port = $3.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkAlarmOccur(hh3cEntityExtErrorCode=0474002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.57

A major internal link fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.58 (hh3cEntityExtInternalLinkAlarmClear)

ON

 

Notification triggers

This notification is generated when CRC errors on an IPC link exceed the threshold. (hh3cEntityExtErrorCode=0474002): Number of errors on the link $1 reached or exceeded the fault threshold. Source port = $2, Destination port = $3.

System impact

Service flapping might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkAlarmClear(hh3cEntityExtErrorCode=0474002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.58

A major internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when CRC errors on an IPC link falls below the threshold. (hh3cEntityExtErrorCode=0474002): Number of errors on the link $1 dropped below the fault threshold. Source port = $2, Destination port = $3.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0474001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.55

A critical internal link fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.56 (hh3cEntityExtInternalLinkFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when an IPC link goes down. (hh3cEntityExtErrorCode=0474001): The link $1 went down. Source port = $2, Destination port =$3.

System impact

The card might reboot and service might flap.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0474001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.56

A critical internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when an IPC link comes up from down state. (hh3cEntityExtErrorCode=0474001): The link came up. Source port = $1, Destination port = $2.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0474011)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.55

A critical internal link fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.56 (hh3cEntityExtInternalLinkFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when an IPC link flaps. (hh3cEntityExtErrorCode=0474011): IPC link flapped.

System impact

The card reboot and service might flap.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0474011)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.56

A critical internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the IPC link flapping issue is cleared. (hh3cEntityExtErrorCode=0474011): IPC link flapping issue removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkAlarmOccur(hh3cEntityExtErrorCode=0428001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.57

A major internal link fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.58 (hh3cEntityExtInternalLinkAlarmClear)

ON

 

Notification triggers

This notification is generated when a PHY chip link failure is detected. (hh3cEntityExtErrorCode=0428001): PHY chip link failure detected.

System impact

The card might reboot and service might flap.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkAlarmClear(hh3cEntityExtErrorCode=0428001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.58

A major internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a PHY chip link recovers from a failure. (hh3cEntityExtErrorCode=0428001): PHY chip link recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when read/write access to the PHY chip fails. (hh3cEntityExtErrorCode=0428002): Communication with the PHY chip failed.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=0428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write access to the PHY chip. (hh3cEntityExtErrorCode=0428002): Communication with the PHY chip restored.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0427002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when read/write to a MAC chip on a card fails. (hh3cEntityExtErrorCode=0427002): Failed to access the MAC chip.

System impact

A hardware failure is detected, and a service failure might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, contact H3C Support.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=0427002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restored access to a MAC chip on a card. (hh3cEntityExtErrorCode=0427002): Restored access to the MAC chip.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=0422002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when an uncorrectable ECC error occurs on an NP on a card.(hh3cEntityExtErrorCode=0422002): Uncorrectable ECC error occurred on the NP.

System impact

If the error occurs on a non-critical location, the card will operate correctly. If the error occurs on a critical location, the card might fail to operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the card status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=0422003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when a PIC interface error occurs on a card. (hh3cEntityExtErrorCode=0422003): PCI_OFFLOAD error occurred on the NP.

System impact

The card services might be abnormal, and the card might reboot immediately.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the card status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write access to the DS31400 clock chip on an ATM subcard fails. (hh3cEntityExtErrorCode=10432016): Board PLL chip read/write failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write access to the DS31400 clock chip on an ATM subcard. (hh3cEntityExtErrorCode=10432016): Board PLL chip read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write access to the DS31400 clock chip on a POS subcard fails. (hh3cEntityExtErrorCode=20432016): Board PLL chip read/write failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write access to the DS31400 clock chip on a POS subcard. (hh3cEntityExtErrorCode=20432016): Board PLL chip read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=30432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write access to the DS31400 clock chip on a CPOS subcard fails.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=30432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write access to the DS31400 clock chip on a CPOS subcard. (hh3cEntityExtErrorCode=30432016): Board PLL chip read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write access to the DS31400 clock chip on an E1T1 subcard fails.(hh3cEntityExtErrorCode=40432016): Board PLL chip read/write failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=40432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write access to the DS31400 clock chip on an E1T1 subcard. (hh3cEntityExtErrorCode=40432016): Board PLL chip read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write access to the zl30165 clock chip on a POS subcard fails. (hh3cEntityExtErrorCode=50432016): Board PLL chip read/write failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=50432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write access to the zl30165 clock chip on a POS subcard. (hh3cEntityExtErrorCode=50432016): Board PLL chip read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=60432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when read/write access to the si30165 clock chip on a subcard adapter fails. (hh3cEntityExtErrorCode=60432016): Board PLL chip read/write failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=60432016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system restores read/write access to the si30165 clock chip on a subcard adapter. (hh3cEntityExtErrorCode=60432016): Board PLL chip read/write recovered.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when a local bus error occurs on an ATM subcard. (hh3cEntityExtErrorCode=10440003): FPGA local bus error.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the local bus error on an ATM subcard is cleared. (hh3cEntityExtErrorCode=10440003): FPGA local bus error removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when an FPGA local bus error occurs on a POS subcard. (hh3cEntityExtErrorCode=20440003): FPGA local bus error.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA local bus error on a POS card is cleared. (hh3cEntityExtErrorCode=20440003): FPGA local bus error remove.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=30440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when an FPGA local bus error occurs on a CPOS subcard. (hh3cEntityExtErrorCode=30440003): FPGA local bus error.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=30440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA local bus error on a CPOS subcard is cleared. (hh3cEntityExtErrorCode=30440003): FPGA local bus error removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when an FPGA local bus error occurs on an E1T1 subcard. (hh3cEntityExtErrorCode=40440003): FPGA local bus error.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=40440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA local bus error on an E1T1 subcard is cleared. (hh3cEntityExtErrorCode=40440003)FPGA local bus error removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when an FPGA local bus error occurs on a subcard adapter. (hh3cEntityExtErrorCode=50440003): FPGA local bus error.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=50440003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA local bus error on a subcard adapter is cleared. (hh3cEntityExtErrorCode=50440003): FPGA local bus error removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when an FPGA SEU error occurs on a WAN card. (hh3cEntityExtErrorCode=10440009): FPGA SEU error.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA SEU error on a WAN card is cleared. (hh3cEntityExtErrorCode=10440009): FPGA SEU error removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=20440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when an FPGA SEU error occurs on a subcard adapter. (hh3cEntityExtErrorCode=20440009): FPGA SEU error.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=20440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA SEU error on a subcard adapter is cleared. (hh3cEntityExtErrorCode=20440009): FPGA SEU error removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=10442001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when a DF400 error occurs. (hh3cEntityExtErrorCode=10442001): Retimer access failure.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=10442001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a DF400 error is cleared. (hh3cEntityExtErrorCode=10442001): Retimer access failure.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Yes

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

No

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Resource Info

No

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

No

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Fault Reason

No

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=10440008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when the FPGA PLL on an ATM subcard goes out of lock. (hh3cEntityExtErrorCode=10440008): FPGA PLL unlocked.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=10440008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA PLL on an ATM subcard restores to the locked state. (hh3cEntityExtErrorCode=10440008): FPGA PLL locked.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=20440008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when the FPGA PLL on a POS subcard goes out of lock. (hh3cEntityExtErrorCode=20440008): FPGA PLL unlocked.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=20440008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA PLL on a POS subcard restores to locked state. (hh3cEntityExtErrorCode=20440008): FPGA PLL locked.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardFatalAlarmOccur(hh3cEntityExtErrorCode=30440008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.7

A critical card fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when the FPGA PLL on a subcard adapter goes out of lock. (hh3cEntityExtErrorCode=30440008): FPGA PLL unlocked.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardFatalAlarmClear(hh3cEntityExtErrorCode=30440008)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.8

A critical card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the FPGA PLL on a subcard adapter restored to the locked state. (hh3cEntityExtErrorCode=30440008): FPGA PLL locked.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=10428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when a PHY chip error occurs on an ATM subcard. (hh3cEntityExtErrorCode=10428002): Communication with phy chip failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=10428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the PHY chip error on an ATM subcard is cleared. (hh3cEntityExtErrorCode=10428002): Communication with phy chip restored.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=10428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when a PHY chip error occurs on a POS subcard. (hh3cEntityExtErrorCode=20428002): Communication with phy chip failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

Reboot the subcard.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=20428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the PHY chip error on a POS subcard is cleared. (hh3cEntityExtErrorCode=20428002): Communication with phy chip restored.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=30428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when a PHY chip error on a CPOS subcard. (hh3cEntityExtErrorCode=30428002): Communication with phy chip failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, reboot the subcard.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=30428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the PHY chip error on a CPOS subcard is cleared. (hh3cEntityExtErrorCode=30428002): Communication with phy chip restored.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=40428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when a PHY chip error occurs on an E1T1 subcard. (hh3cEntityExtErrorCode=40428002): Communication with phy chip failed.

System impact

The subcard cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue, reboot the subcard.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=40428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the PHY chip error on an E1T1 subcard is cleared. (hh3cEntityExtErrorCode=40428002): Communication with phy chip restored.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when uncorrectable FPGA SEU errors are increasing. (hh3cEntityExtErrorCode=40440009): FPGA SEU error.

System impact

Error packets might occur.

Status control

You can disable this notification simply by disabling FMEA.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Reboot the subcard.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=40440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when uncorrectable FPGA SEU errors stop increasing. (hh3cEntityExtErrorCode=40440009): FPGA SEU error removed.

System impact

No negative impact on the system.

Status control

You can disable this notification simply by disabling FMEA.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when uncorrectable FPGA SEU errors are increasing. (hh3cEntityExtErrorCode=50440009): FPGA SEU error.

System impact

Error packets might occur.

Status control

You can disable this notification simply by disabling FMEA.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Reboot the subcard.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=50440009)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when uncorrectable FPGA SEU errors stop increasing. (hh3cEntityExtErrorCode=50440009): FPGA SEU error removed.

System impact

No negative impact on the system.

Status control

You can disable this notification simply by disabling FMEA.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0423033)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when parity and ECC errors on the switch chip reach or exceed the threshold in a specified period of time. (hh3cEntityExtErrorCode==0423033): Number of parity and ECC errors on the switch chip reached or exceeded the threshold.

System impact

Packet loss or traffic interruption might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the service status. If the services are normal, no action is required. If the services are abnormal, reboot the service module.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=0423033)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when parity and ECC errors on the switch chip fall below the threshold in a specified period of time. (hh3cEntityExtErrorCode==0423033): Number of parity and ECC errors on the switch chip dropped below the threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0422016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when parity and ECC errors on an NP chip in a specified period of time reach or exceed the threshold. (hh3cEntityExtErrorCode==0422016): Number of parity and ECC errors on the NP reached or exceeded the threshold.

System impact

Packet loss or traffic interruption might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check service status. If the services are normal, no action is required. If the services are abnormal, reboot the service module.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardWarningClear(hh3cEntityExtErrorCode=0422016)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.12

A card warning was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when parity and ECC errors on an NP chip in a specified period of time falls below the threshold. (hh3cEntityExtErrorCode==0422016): Number of parity and ECC errors on the NP dropped below the threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardWarningOccur(hh3cEntityExtErrorCode=0428002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.11

A card warning occurred.

Error

Warning

1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear)

ON

 

Notification triggers

This notification is generated when read/write to the PHY chip fails. (hh3cEntityExtErrorCode==0428002): Communication with the PHY chip failed.

System impact

Packet loss might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Reboot the switching fabric module.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkAlarmOccur(hh3cEntityExtErrorCode=0479003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.57

A major internal link fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.58 (hh3cEntityExtInternalLinkAlarmClear)

ON

 

Notification triggers

This notification is generated when CRC errors on an Interlaken link reach or exceed the threshold. (hh3cEntityExtErrorCode==0479003): Number of CRC errors on the Interlaken link reached or exceeded the threshold.

System impact

Packet loss might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkAlarmClear(hh3cEntityExtErrorCode=0479003)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.58

A major internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when CRC errors on an Interlaken link fall below the threshold. (hh3cEntityExtErrorCode==0479003): Number of CRC errors on the Interlaken link dropped below the threshold.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkAlarmOccur(hh3cEntityExtErrorCode=0473002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.57

A major internal link fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.58 (hh3cEntityExtInternalLinkAlarmClear)

ON

 

Notification triggers

This notification is generated when an error occurs on the data channel between switch chips. (hh3cEntityExtErrorCode==0473002): An error occurred on the data channel between switch chips.

System impact

Packet loss might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkAlarmClear(hh3cEntityExtErrorCode=0473002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.58

A major internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the error on the data channel between switch chips is cleared. (hh3cEntityExtErrorCode==0473002): Error removed from the data channel between switch chips.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0479001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.55

A critical internal link fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.56 (hh3cEntityExtInternalLinkFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when an Interlaken link goes down. (hh3cEntityExtErrorCode==0479001): Interlaken link went down.

System impact

The service module cannot operate correctly.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.Reboot the service module.

3.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0479001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.56

A critical internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when an Interlaken link comes up from down state. (hh3cEntityExtErrorCode==0479001): Interlaken link came up.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtInternalLinkFatalAlarmOccur(hh3cEntityExtErrorCode=0479002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.55

A critical internal link fault occurred.

Error

Critical

1.3.6.1.4.1.25506.2.6.4.0.56 (hh3cEntityExtInternalLinkFatalAlarmClear)

ON

 

Notification triggers

This notification is generated when an Interlaken link flaps. (hh3cEntityExtErrorCode==0479002): Interlaken link flapped.

System impact

Packet loss or traffic interruption might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Check the internal link status and take actions to resolve any issues identified.

2.Reboot the service module.

3.If the issue persists, contact H3C Support.

hh3cEntityExtInternalLinkFatalAlarmClear(hh3cEntityExtErrorCode=0479002)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.56

A critical internal link fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the Interlaken link flapping issue is cleared. (hh3cEntityExtErrorCode==0479002): Interlaken link flapping issue removed.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

hh3cEntityExtBoardAlarmOccur(hh3cEntityExtErrorCode=0425001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.9

A major card fault occurred.

Error

Major

1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear)

ON

 

Notification triggers

This notification is generated when a TCAM error occurs on a chip. (hh3cEntityExtErrorCode=0425001): TCAM error on chip $1. Detailed information:SoftErr.

System impact

Routing and ACL services might be affected.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

To resolve the issue:

1.Reboot the service module.

2.If the issue persists, contact H3C Support.

hh3cEntityExtBoardAlarmClear(hh3cEntityExtErrorCode=0425001)

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.6.4.0.10

A major card fault was cleared.

Recovery

_

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the TCAM error on a chip is cleared. (hh3cEntityExtErrorCode=0425001): TCAM error removed on chip $1. Detailed information: None.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex)

Entity index.

Y

Integer32

Standard MIB values.

1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName)

Entity name.

N

SnmpAdminString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource)

Entity location information.

N

OCTECT STRING

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode)

Error code.

N

Integer32

See notification triggers.

1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason)

Failure cause description.

N

OCTECT STRING

See notification triggers.

 

Recommended action

No action is required.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网