H3C ES42_S16V2_ES-R8831P01

Release time:2026-09-23
HomeSupportSwitchesS1600 SeriesS1600V2 SeriesSoftware DownloadES42-S16V2-ES Series

 

H3C ES42_S16V2_ES-R8831P01 Release Notes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H3C_彩色.emf


Contents

Introduction· 1

Version information· 1

Version number 1

Version history· 1

Hardware and software compatibility matrix· 1

Upgrade advice· 2

Upgrade restrictions and guidelines· 2

Hardware feature updates· 2

R8831P01· 2

R8831· 2

R8829P01· 2

R8829· 2

R8828· 3

R8821· 3

R8812· 3

R8808· 3

E8807· 3

Software feature and command updates· 3

R8831P01· 3

R8831· 3

Modified feature: Enabling transparent transmission of LLDP frames for voice VLAN negotiation· 3

Modified feature: Controlling panel LEDs in the AON Ethernet system·· 4

Modified feature: Obtaining location information about an endpoint connected to an iOptic node by the endpoint's MAC address on the AON aggregation· 4

Modified feature: Adding an operation risk warning for forced PoE power supply· 4

R8829P01· 4

R8829· 4

Modified feature: Support of PoE models for forced PoE power supply· 4

Modified feature: Support of PoE models for PoE standard display· 5

R8828· 5

Modified feature: Performing transceiver module diagnostics in the local Web interface· 5

Modified feature: Displaying LLDP neighbor information in the local Web interface· 6

Modified feature: Performing ping operations in the local Web interface· 6

Modified feature: Configuring static link aggregation in the local Web interface· 6

Modified feature: Configuring PoE watchdog in the local Web interface· 6

Modified feature: Configuring VLANs in the local Web interface· 6

R8821· 7

R8812· 7

New feature: The ES4200 device operates in iOptic Node mode by default, aggregating between the default upstream ports. 7

New feature: Online upgrade from the Web interface· 7

New feature: Redirection to Cloudnet from the WEB interface· 7

New feature: Logging· 7

Modified feature: Button for enabling or disabling Cloudnet and UWEB connection· 8

Modified feature: Synchronization of device Web settings with Cloudnet 8

Modified feature: Cloudnet authentication· 8

R8808· 8

E8807· 9

Operation changes· 9

Operation changes in R8831P01· 9

Operation changes in R8831· 9

Operation changes in R8829P01· 9

Operation changes in R8829· 9

Operation changes in R8828· 9

Operation changes in R8821· 9

Operation changes in R8812· 9

Operation changes in R8808· 9

Operation changes in E8807· 9

Restrictions and cautions· 10

Restrictions· 10

Hardware· 10

Software· 10

Network configuration· 10

Cautions· 10

Hardware· 10

Software· 10

Network configuration· 10

Open problems and workarounds· 10

List of resolved problems· 11

Resolved problems in R8831P01· 11

Resolved problems in R8831· 11

Resolved problems in R8829P01· 12

Resolved problems in R8829· 12

Resolved problems in R8828· 12

Resolved problems in R8821· 12

Resolved problems in R8812· 12

Resolved problems in R8808· 14

Resolved problems in E8807· 14

Related documentation· 15

Related documents· 15

Obtaining the documents· 15

Technical support 15

Appendix A Feature list 16

Appendix B Fixed security vulnerabilities· 18

Appendix C Upgrading software· 19

Upgrading software through the webpage· 20

Upgrading Software through the TFTP· 20

Handling software upgrade failures· 20

 



Introduction

This document describes the features, restrictions and guidelines, open problems, and workarounds for version ES42_S16V2_ES-R8831P01. Before you use this version on a live network, back up the configuration and test the version to avoid software upgrade affecting your live network.

Use this document in conjunction with the documents listed in "Related documentation."

Version information

Version number

Release 8831P01

Note: You can see the version number on the webpage.

Version history

Table 1 Version history

Version number

Last version

Release date

Release type

Remarks

ES42_S16V2_ES-R8831P01

ES42_S16V2_ES-R8831

2026-09-02

Release version

Fixed bugs

ES42_S16V2_ES-R8831

ES42_S16V2_ES-R8829P01

2026-06-12

Release version

Fixed bugs

ES42_S16V2_ES-R8829P01

ES42_S16V2_ES-R8829

2025-12-12

Release version

Fixed bugs

ES42_S16V2_ES-R8829

ES42_S16V2_ES-R8828

2025-10-20

Release version

Fixed bugs

ES42_S16V2_ES-R8828

S1600V2_ES-R8821

2025-07-31

Release version

Fixed bugs

S1600V2_ES-R8821

ES42_S16V2_ES-R8812

2025-03-18

Release version

Fixed bugs

ES42_S16V2_ES-R8812

ES42_S16V2_ES-R8808

2024-07-25

Release version

New Feature

ES42_S16V2_ES-R8808

ES42_S16V2_ES-E8807

2024-03-12

Release version

Fixed bugs

ES42_S16V2_ES-E8807

First release

2024-02-28

Ess version

First release

 

Hardware and software compatibility matrix

CAUTION

CAUTION:

To avoid an upgrade failure, use Table 2 to verify the hardware and software compatibility before performing an upgrade.

 

Table 2 Hardware and software compatibility matrix

Item

Specifications

Product family

S1600V2_ES4200

Hardware platform

ES4200-16T2RX

S1600V2-26S

S1600V2-26S-HPWR

Memory

128 MB

Flash

16 MB

Boot ROM version

N/A

Image file name and MD5 checksum

ES42_S16V2_ES-R8831P01.bin (See the MD5 file)

iMC version

N/A

iNode version

N/A

Unified wired and wireless AC version

N/A

 

Upgrade advice

Upgrade to this version as needed to gain benefits introduced in this version.

Upgrade restrictions and guidelines

None.

Hardware feature updates

R8831P01

None.

R8831

None.

R8829P01

None.

R8829

None.

R8828

None.

R8821

None.

R8812

None.

R8808

None.

E8807

First release.

Software feature and command updates

R8831P01

None.

R8831

Modified feature: Enabling transparent transmission of LLDP frames for voice VLAN negotiation

Feature change description

As from this release, the system supports transparent transmission of LLDP frames for voice VLAN negotiation.

Command changes

None.

Modified feature: Controlling panel LEDs in the AON Ethernet system

Feature change description

After the device connects to an AON aggregation as an AON node, you can remotely turn off and restore the AON node panel LEDs on the AON aggregation. (Use this feature together with an AON aggregation version that supports it.)

Command changes

None.

Modified feature: Obtaining location information about an endpoint connected to an iOptic node by the endpoint's MAC address on the AON aggregation

Feature change description

After the device connects to an AON aggregation as an AON node, you can obtain location information about an endpoint connected to the AON node by the endpoint's MAC address on the AON aggregation. (Use this feature together with an AON aggregation version that supports it.)

Command changes

None.

Modified feature: Adding an operation risk warning for forced PoE power supply

Feature change description

When you enable forced PoE forced power supply on the local Web interface, the system adds an operation risk warning before you can continue.

Command changes

None.

R8829P01

None.

R8829

Modified feature: Support of PoE models for forced PoE power supply

Feature change description

The forced PoE power supply feature is newly added to the PoE Info page for PoE models.

 

Command changes

None.

Modified feature: Support of PoE models for PoE standard display

Feature change description

For a PoE model, its Web interface can display the supported PoE standards. The PoE standard for a port is displayed as af, at, or bt.

 

Command changes

None.

R8828

Modified feature: Performing transceiver module diagnostics in the local Web interface

Feature change description

As from this version, the local Web interface supports transceiver module diagnostics. You can view basic information about installed transceiver modules on the Web page, including interface type, wavelength, and serial number. For transceiver modules that comply with the SFF-8472 protocol, the page also displays Tx and Rx optical power information, facilitating debugging and maintenance of all-optical networks.

Command changes

None.

Modified feature: Displaying LLDP neighbor information in the local Web interface

Feature change description

Added support of local Web interface for displaying LLDP neighbor information.

Command changes

None.

Modified feature: Performing ping operations in the local Web interface

Feature change description

Added support of local Web interface for ping operations. As from this release, you can ping an IP address or domain name for connectivity test in the local Web interface.

Command changes

None.

Modified feature: Configuring static link aggregation in the local Web interface

Feature change description

Added support of local Web interface for static link aggregation. As from this release, you can configure up to four aggregation groups in the local Web interface, with each group supporting up to eight ports.

Command changes

None.

Modified feature: Configuring PoE watchdog in the local Web interface

Feature change description

Added support of local Web interface for PoE watchdog.

Command changes

None.

Modified feature: Configuring VLANs in the local Web interface

Feature change description

As from this release, you can configure up to 32 VLANs in the local Web interface.

Command changes

None.

R8821

None.

R8812

New feature: The ES4200 device operates in iOptic Node mode by default, aggregating between the default upstream ports.

Feature change description

As from this release, the two uplink fiber ports on an ES4200 switch are assigned to an aggregation group in iOptic node mode by default, and the configuration cannot be canceled. You can see the iOptic node's aggregation group settings and rate on the iOptic host after the iOptic node comes online on the iOptic host. You can execute the link command on the iOptic host to configure link aggregation for the iOptic node. The iOptic host displays an error message when a link aggregation configuration error occurs.

Command reference

None.

New feature: Online upgrade from the Web interface

Feature change description

As from this release, you can upgrade your switch to the most recent version directly from Cloudnet without downloading the device firmware to your local computer after the switch automatically connects to the Internet and Cloudnet. This simplifies the upgrade process.

Command reference

None.

New feature: Redirection to Cloudnet from the WEB interface

Feature change description

As from this release, after the switch comes online on Cloudnet/UWEB, you will be redirected to the Cloudnet login page by default after you click a hyperlink on the Web interface.

Command reference

None.

New feature: Logging

Feature change description

As from this release, the device supports the logging feature.

Log entry generation and saving

The device generates corresponding log entries when you configure the switch or when the switch state changes, and saves them in the storage media, ensuring that they are not lost after a reboot.

Scheduled state information report to Cloudnet

The device generates log entries and sends notifications to Cloudnet when state change occurs, allowing Cloudnet to synchronize the device state in the network.

Reading log entries by Cloudnet

Cloudnet reads local log files every 24 hours and stores them in its log folder. Device R&D and service personnel can access these local log files on Cloudnet to monitor device performance. This feature is not available to users and can only be accessed through the Cloudnet gateway.

Command reference

None.

Modified feature: Button for enabling or disabling Cloudnet and UWEB connection

Feature change description

A button was added on the homepage of the local Web interface for users to enable or disable Cloudnet and UWEB connection. With this feature disabled, the device will not actively connect to Cloudnet or respond to UWEB's connection requests.

Command changes

None.

Modified feature: Synchronization of device Web settings with Cloudnet

Feature change description

As from this release, when you configure settings supported by Cloudnet on the local Web interface of a device connected to Cloudnet, the device sends a notification to notify Cloudnet to read device configuration.

Command changes

None.

Modified feature: Cloudnet authentication

Feature change description

A new authentication feature was added. When you bind a device on the Cloudnet Web interface, you must enter the account name and password for verification. The device can be successfully bound only when the account name and password are correct.

When you enter the device serial number, account name, and password on the Cloudnet Web interface, Cloudnet sends the account name and password to IoT for verification. Based on the verification result from IoT, Cloudnet determines whether the device can be successfully bound.

Command changes

None.

R8808

None.

E8807

First release.

Operation changes

Operation changes in R8831P01

None.

Operation changes in R8831

None.

Operation changes in R8829P01

Before modification: The PoE standard of PoE model devices is initialized to af mode by default.

After modification: The PoE standard of PoE model devices is initialized to at mode by default.

Operation changes in R8829

None.

Operation changes in R8828

None.

Operation changes in R8821

None.

Operation changes in R8812

None.

Operation changes in R8808

None.

Operation changes in E8807

First release.

Restrictions and cautions

Before upgrading the software, check the software feature changes between versions, assess the potential impact of these changes on your business, and read the related documents.

Restrictions

Hardware

None.

Software

When you shut down the peer port or the port is up, the VCT detection results might be inaccurate. The port might be displayed as in abnormal status, for example, mismatch, disconnected, or short-circuit.

Network configuration

None.

Cautions

Hardware

None.

Software

None.

Network configuration

None.

Open problems and workarounds

202606091249

·         Symptom: After you push a large number of port configurations in bulk, the device configurations actually take effect, but the system returns a "Time out" error message.

·         Condition: This symptom might occur if you select a large number of ports for batch configuration and deployment in a single operation on the overseas Cloudnet platform.

·         Workaround: Select fewer ports in each batch configuration operation.

202606031761

·         Symptom: When you check the loop status on the ES4200 device, the information indicates that the port does not enter the blockade state, and no actual traffic storm occurs.

·         Condition: This symptom might occur if an iOptic host connects to two ES4200-ES series devices and form a physical loop.

·         Workaround: Design your network topology to avoid physical loops.

List of resolved problems

Resolved problems in R8831P01

202511210947

·           Symptom: The page loads slowly or fails to load when you log in to the Web page.

·           Condition: This symptom occurs if you use Cloudnet to remotely log in to the Web page, and the router’s TCP MSS field value is too low after endian conversion.

Resolved problems in R8831

202512031997

·         Symptom: After you enable the anti-tampering feature on the Aolynk cloud platform, the device's uplink port does not automatically become a trusted port.

·         Condition: This symptom might occur when the Aolynk cloud platform manages the device and anti-tampering is enabled through the platform.

202604271410

·         Symptom: When you run a network test on the device, significant response latency (high ping latency) exists. If the device operates in AON node mode with significant response latency, it will frequently come online and go offline in the AON Ethernet system.

·         Condition: This symptom occurs on PoE models.

202604200831

·         Symptom: The enabling status of PoE on the local Web interface is inconsistent with that on Cloudnet, where the status error occurs.

·         Condition: This symptom might occur if the device is managed by Cloudnet.

202511140551

·         Symptom: In standalone mode, changing the default VLAN to the management VLAN causes the device's original IP address to become invalid.

·         Condition: The device is in standalone mode. When it is integrated into the iOptic Ethernet networking, the management VLAN used for networking does not match the VLAN where the device currently resides.

202605291567

·         Symptom: The forced PoE power supply feature configured on the local Web interface fails to recover to the default disabled state as expected.

·         Condition: This symptom might occur if you enable forced PoE power supply and perform a mode switchover.

202512101285

·         Symptom: The PoE standard displayed on the device's local web interface is incorrect; the correct one should be AT mode.

·         Condition: The device is powered on and running. Log in to the device's local web interface, navigate to the PoE information page, and check the "PoE standard" display.

Resolved problems in R8829P01

202510170524

·         Symptom: After the iOptic Host manages the AON node and incorporates it into the analyzer, the analyzer is unable to retrieve optical link data such as ES4200 wavelength, rate, and bandwidth.

·         Condition: The device is powered on and running, with the iOptic Host managing the AON node and integrating it into the analyzer.

Resolved problems in R8829

None.

Resolved problems in R8828

202507081734

·         Symptom: An AON node (also called iOptic node) failed to upgrade automatically.

·         Condition: This symptom occurs if the following conditions are met:

¡  Automatic upgrade for AON nodes is enabled in the AON Ethernet system.

¡  The AON node comes online again after it goes offline because its upgrade process is interrupted by AON aggregation (also called iOptic host) restart, configuration deletion or network disruption.

202506230608

·         Symptom: Some AON nodes cannot come online automatically.

·         Condition: This symptom might occur if AON nodes go offline in bulk, and then come online in bulk in the AON Ethernet system.

202409250402

·         Symptom: Packets with VLAN tags identical to the PVIDs of local ports are not forwarded.

·         Condition: This symptom occurs if you configure multiple ports as trunk ports, and some of them have traffic anomalies.

Resolved problems in R8821

None.

Resolved problems in R8812

202406251829

·         Symptom: The device is not responding and requests time out.

·         Condition: This symptom might occur if the UWEB issues loop prevention configuration.

202406132243

·         Symptom: The IP address of the iOptic host is displayed as 0.

·         Condition: This symptom might occur if an iOptic node comes online.

202406130892

·         Symptom: The time format is incorrect.

·         Condition: This symptom might occur on the Web homepage.

202406071855

·         Symptom: Failed to delete static MAC addresses. The page prompts an error message.

·         Condition: This symptom might occur if you delete static MAC addresses on the Web interface.

202406031607

·         Symptom: Failed to delete blackhole MAC addresses.

·         Condition: This symptom occurs if you delete dynamic MAC addresses from the MAC address list.

202406030635

·         Symptom: Downlink ports cannot forward traffic.

·         Condition: This symptom occurs if you disable port isolation.

202405281654

·         Symptom: The domain name has failed to be restored to the factory default setting.

·         Condition: This symptom occurs if you restore the device to factory defaults.

202405211202

·         Symptom: The device cannot come online.

·         Condition: This symptom occurs if a self loop exists on the device.

202405160474

·         Symptom: No prompt is displayed when you enter an invalid MAC address.

·         Condition: This symptom might occur if you enter an invalid MAC address.

202405130172

·         Symptom: Incorrect PoE information.

·         Condition: This symptom occurs if you log in to the Cloudnet and PoE information is reported to the Cloudnet.

202405100715

·         Symptom: Incorrect LLDP neighbor information.

·         Condition: This symptom might occur if the device is incorporated by an iOptic host.

202404291242

·         Symptom: The returned error message is incorrect.

·         Condition: This symptom occurs if you add VLAN 1.

202406140184

·         Symptom: Inappropriate password specification.

·         Condition: This symptom occurs if you change the password.

202405150817

·         Symptom: DHCP snooping has failed to be enabled.

·         Condition: This symptom might occur if you enable DHCP snooping on the Cloudnet.

Resolved problems in R8808

202401311607

·         Symptom: The device has crashed, and the Web interface for the switch is inaccessible.

·         Condition: This symptom occurs if the device connects to Cloudnet in an overseas test environment.

202401171172

·         Symptom: Enabling DHCP still allows a client to obtain an IP address after you configure the MAC address of the client or server as a blackhole MAC address.

·         Condition: This symptom occurs if you configure the MAC address of the client or server as a blackhole MAC address.

202401311723

·         Symptom: The MAC addresses of packets cannot be learned, and traffic cannot be forwarded correctly.

·         Condition: This symptom occurs if the VLAN ID in the transmitted packets is 0.

202401311549

·         Symptom: A device is unincorporated.

·         Condition: This symptom occurs if you create 32 static MAC address entries and then bulk delete all of them on the device.

202401100786

·         Symptom: DHCP does not automatically renew leases.

·         Condition: This symptom occurs if the IP addresses obtained through DHCP expire.

202401261600

·         Symptom: The packet statistics displayed are incorrect.

·         Condition: This symptom occurs if you view the traffic statistics on a switch after the switch is incorporated by the iOptic host.

202401250221

·         Symptom: The interface speeds displayed are incorrect.

·         Condition: This symptom occurs if you view the interface speeds on a switch after the switch is incorporated by the iOptic host.

202403110823

·         Symptom: The port mirroring configuration displayed is incorrect.

·         Condition: This symptom occurs if you configure port mirroring, delete the configuration, and then reboot the device.

Resolved problems in E8807

First release.

Related documentation

Related documents

·         H3C ES4200 Switch Series Installation Guide

·         H3C ES4200 Switch Series Hardware Information and Specifications

·         H3C S1600V2 Switch Series Installation Guide

·         H3C S1600V2 Switch Series Hardware Information and Specifications

·         H3C S1600V2_ES4200 Switch Series Web Configuration Guide

Obtaining the documents

To obtain the latest documents:

1.       Access http://www.h3c.com/en/Technical_Documents

2.       Select the product category and product model. Then, you can query and download documents related to the product.

Technical support

Email: service@h3c.com

Website: http://www.h3c.com/en


Appendix A Feature list

Hardware features

See H3C ES4200/S1600V2 Switch Series Installation Guide.

Software features

Table 3 Software features

 

Supported features

ES4200-16T2RX

S1600V2-26S

S1600V2-26S-HPWR

MAC address table

Maximum number of addresses supported

16k

16k

16k

Supported features

32 static address entries

Blackhole MAC address entries

MAC address learning and aging

VLAN

16 port-based VLANs

Access/trunk mode configuration

Port management

Rate/duplex mode configuration

Flow control

Bring up/shutting down ports

PoE

Enabling/disabling PoE for ports

Display of total, used, and free power.

IP management

Static IP configuration

Address acquisition through DHCP

Upgrade

System upgrade through webpage

Maintenance

Ping operations

Restoring factory defaults by one click

One-click restart

Saving configuration

Port mirroring

Port mirroring configuration

Port isolation

Port isolation

Loop detection and prevention

Loop protection

Cable detection

Cable detection

Port rate limit

Port rate limit

Storm control

Storm control configuration

Buttons

Switchover between normal mode and PoE mode by pressing the mode LED.

Press the reset button restarting the device. Press and hold the reset button for 1 to 5 seconds resetting the password. Press and hold the reset button for 5 to 10 seconds restoring the factory defaults. Press and hold the reset button for over 10 seconds restores the device to normal state.

 

 

 

NOTE:

For ease of readability, the capacity and speed units megabits per second (Mbit/s) and gigabits per second are abbreviated as M and G, respectively.

 

 



Appendix C Upgrading software

About device software

The device software mainly includes the boot loader program and the startup software package. After the device starts, it first runs the boot loader program to initialize hardware, and then runs the startup software package. The boot loader program and startup software package are required for the device startup and operation. They provide support, management, and service functionalities for the entire device. Figure 1 shows the relationship between boot loader and startup software package

Figure 1 Relationship between boot loader and startup software package

 

NOTE:

The boot loader file is not released with the product software. To obtain the boot loader file, contact H3C Support.

 

Upgrade methods

Models

Upgrade method

Description

ES4200-16T2RX

S1600V2-26S

S1600V2-26S-HPWR

Upgrading

·        A restart is required after upgrade.

·        Upgrading software by using this method interrupts services.

Upgrading software through the webpage

Upgrade software by using this method when the device is disconnected.

 

Upgrading software through the webpage

1.       Log in to the web management interface of the device, and then select System > System Upgrade from the navigation pane.

2.       Select the target package file, and then click Upgrade.

During the upgrade, do not perform any actions on the device. The device automatically restarts after the upgrade is completed.

3.       View the version information to verify that the software has been upgraded to the target version successfully.

Upgrading Software through the TFTP

1.       Open the tftp software on the PC as the server, the IP address is 192.168.0.254, and the device serves as the tftp client.

2.       Start the device and press and hold the reset button at the same time. The device will automatically obtain the upgrade package named ES4200_US200_ES.bin under the IP address 192.168.0.254.

3.       After the upgrade is completed, the device automatically restarts to take effect.

4.       After the upgrade through this method is completed and the device is restarted, to ensure correct use, it should be upgraded again in the web upgrade interface.

Handling software upgrade failures

If a software upgrade fails, the system runs the old software version. To handle a software failure:

1.       Check the physical ports for a loose or incorrect connection.

2.       If you log in to the device through a webpage, refresh the webpage to verify that the web connection is in good condition.

3.       Verify that the software package is compatible with the device model, and the software package type is correct.

4.       Verify that the startup software package version is correct. For more information, see "Hardware and software compatibility matrix."

5.       If you cannot access the webpage, upgrade the software by using the boot loader method.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us