| Title | Size | Downloads |
|---|---|---|
| ES42_S16V2_ES-R8831P01.zip | 6.75 MB | |
| ES42_S16V2_ES-R8831P01-MD5.rar | 0.15 KB | |
| H3C ES42_S16V2_ES-R8831P01 Release Notes.pdf | 798.99 KB |
H3C ES42_S16V2_ES-R8831P01 Release Notes
Copyright © 2026 New H3C Technologies Co., Ltd. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co., Ltd. The information in this document is subject to change without notice. |
|
Hardware and software compatibility matrix· 1
Upgrade restrictions and guidelines· 2
Software feature and command updates· 3
Modified feature: Enabling transparent transmission of LLDP frames for voice VLAN negotiation· 3
Modified feature: Controlling panel LEDs in the AON Ethernet system·· 4
Modified feature: Adding an operation risk warning for forced PoE power supply· 4
Modified feature: Support of PoE models for forced PoE power supply· 4
Modified feature: Support of PoE models for PoE standard display· 5
Modified feature: Performing transceiver module diagnostics in the local Web interface· 5
Modified feature: Displaying LLDP neighbor information in the local Web interface· 6
Modified feature: Performing ping operations in the local Web interface· 6
Modified feature: Configuring static link aggregation in the local Web interface· 6
Modified feature: Configuring PoE watchdog in the local Web interface· 6
Modified feature: Configuring VLANs in the local Web interface· 6
New feature: Online upgrade from the Web interface· 7
New feature: Redirection to Cloudnet from the WEB interface· 7
Modified feature: Button for enabling or disabling Cloudnet and UWEB connection· 8
Modified feature: Synchronization of device Web settings with Cloudnet 8
Modified feature: Cloudnet authentication· 8
Operation changes in R8831P01· 9
Operation changes in R8829P01· 9
Open problems and workarounds· 10
Resolved problems in R8831P01· 11
Resolved problems in R8831· 11
Resolved problems in R8829P01· 12
Resolved problems in R8829· 12
Resolved problems in R8828· 12
Resolved problems in R8821· 12
Resolved problems in R8812· 12
Resolved problems in R8808· 14
Resolved problems in E8807· 14
Appendix B Fixed security vulnerabilities· 18
Appendix C Upgrading software· 19
Upgrading software through the webpage· 20
Upgrading Software through the TFTP· 20
Handling software upgrade failures· 20
Introduction
This document describes the features, restrictions and guidelines, open problems, and workarounds for version ES42_S16V2_ES-R8831P01. Before you use this version on a live network, back up the configuration and test the version to avoid software upgrade affecting your live network.
Use this document in conjunction with the documents listed in "Related documentation."
Version information
Version number
Release 8831P01
Note: You can see the version number on the webpage.
Version history
Version number | Last version | Release date | Release type | Remarks |
ES42_S16V2_ES-R8831P01 | ES42_S16V2_ES-R8831 | 2026-09-02 | Release version | Fixed bugs |
ES42_S16V2_ES-R8831 | ES42_S16V2_ES-R8829P01 | 2026-06-12 | Release version | Fixed bugs |
ES42_S16V2_ES-R8829P01 | ES42_S16V2_ES-R8829 | 2025-12-12 | Release version | Fixed bugs |
ES42_S16V2_ES-R8829 | ES42_S16V2_ES-R8828 | 2025-10-20 | Release version | Fixed bugs |
ES42_S16V2_ES-R8828 | S1600V2_ES-R8821 | 2025-07-31 | Release version | Fixed bugs |
S1600V2_ES-R8821 | ES42_S16V2_ES-R8812 | 2025-03-18 | Release version | Fixed bugs |
ES42_S16V2_ES-R8812 | ES42_S16V2_ES-R8808 | 2024-07-25 | Release version | New Feature |
ES42_S16V2_ES-R8808 | ES42_S16V2_ES-E8807 | 2024-03-12 | Release version | Fixed bugs |
ES42_S16V2_ES-E8807 | First release | 2024-02-28 | Ess version | First release |
Hardware and software compatibility matrix
| CAUTION: To avoid an upgrade failure, use Table 2 to verify the hardware and software compatibility before performing an upgrade. |
Table 2 Hardware and software compatibility matrix
Item | Specifications |
Product family | S1600V2_ES4200 |
Hardware platform | ES4200-16T2RX S1600V2-26S S1600V2-26S-HPWR |
Memory | 128 MB |
Flash | 16 MB |
Boot ROM version | N/A |
Image file name and MD5 checksum | ES42_S16V2_ES-R8831P01.bin (See the MD5 file) |
iMC version | N/A |
iNode version | N/A |
Unified wired and wireless AC version | N/A |
Upgrade advice
Upgrade to this version as needed to gain benefits introduced in this version.
Upgrade restrictions and guidelines
Hardware feature updates
R8831P01
None.
R8831
None.
R8829P01
None.
R8829
None.
R8828
None.
R8821
None.
R8812
None.
R8808
None.
E8807
Software feature and command updates
R8831P01
None.
R8831
Modified feature: Enabling transparent transmission of LLDP frames for voice VLAN negotiation
Feature change description
As from this release, the system supports transparent transmission of LLDP frames for voice VLAN negotiation.
Command changes
None.
Modified feature: Controlling panel LEDs in the AON Ethernet system
Feature change description
After the device connects to an AON aggregation as an AON node, you can remotely turn off and restore the AON node panel LEDs on the AON aggregation. (Use this feature together with an AON aggregation version that supports it.)
Command changes
None.
Modified feature: Obtaining location information about an endpoint connected to an iOptic node by the endpoint's MAC address on the AON aggregation
Feature change description
After the device connects to an AON aggregation as an AON node, you can obtain location information about an endpoint connected to the AON node by the endpoint's MAC address on the AON aggregation. (Use this feature together with an AON aggregation version that supports it.)
Command changes
None.
Modified feature: Adding an operation risk warning for forced PoE power supply
Feature change description
When you enable forced PoE forced power supply on the local Web interface, the system adds an operation risk warning before you can continue.
Command changes
None.
R8829P01
None.
R8829
Modified feature: Support of PoE models for forced PoE power supply
Feature change description
The forced PoE power supply feature is newly added to the PoE Info page for PoE models.

Command changes
None.
Modified feature: Support of PoE models for PoE standard display
Feature change description
For a PoE model, its Web interface can display the supported PoE standards. The PoE standard for a port is displayed as af, at, or bt.

Command changes
None.
R8828
Modified feature: Performing transceiver module diagnostics in the local Web interface
Feature change description
As from this version, the local Web interface supports transceiver module diagnostics. You can view basic information about installed transceiver modules on the Web page, including interface type, wavelength, and serial number. For transceiver modules that comply with the SFF-8472 protocol, the page also displays Tx and Rx optical power information, facilitating debugging and maintenance of all-optical networks.
Command changes
None.
Modified feature: Displaying LLDP neighbor information in the local Web interface
Feature change description
Added support of local Web interface for displaying LLDP neighbor information.
Command changes
None.
Modified feature: Performing ping operations in the local Web interface
Feature change description
Added support of local Web interface for ping operations. As from this release, you can ping an IP address or domain name for connectivity test in the local Web interface.
Command changes
None.
Modified feature: Configuring static link aggregation in the local Web interface
Feature change description
Added support of local Web interface for static link aggregation. As from this release, you can configure up to four aggregation groups in the local Web interface, with each group supporting up to eight ports.
Command changes
None.
Modified feature: Configuring PoE watchdog in the local Web interface
Feature change description
Added support of local Web interface for PoE watchdog.
Command changes
None.
Modified feature: Configuring VLANs in the local Web interface
Feature change description
As from this release, you can configure up to 32 VLANs in the local Web interface.
Command changes
None.
R8821
None.
R8812
New feature: The ES4200 device operates in iOptic Node mode by default, aggregating between the default upstream ports.
Feature change description
As from this release, the two uplink fiber ports on an ES4200 switch are assigned to an aggregation group in iOptic node mode by default, and the configuration cannot be canceled. You can see the iOptic node's aggregation group settings and rate on the iOptic host after the iOptic node comes online on the iOptic host. You can execute the link command on the iOptic host to configure link aggregation for the iOptic node. The iOptic host displays an error message when a link aggregation configuration error occurs.
Command reference
None.
New feature: Online upgrade from the Web interface
Feature change description
As from this release, you can upgrade your switch to the most recent version directly from Cloudnet without downloading the device firmware to your local computer after the switch automatically connects to the Internet and Cloudnet. This simplifies the upgrade process.
Command reference
None.
New feature: Redirection to Cloudnet from the WEB interface
Feature change description
As from this release, after the switch comes online on Cloudnet/UWEB, you will be redirected to the Cloudnet login page by default after you click a hyperlink on the Web interface.
Command reference
New feature: Logging
Feature change description
As from this release, the device supports the logging feature.
Log entry generation and saving
The device generates corresponding log entries when you configure the switch or when the switch state changes, and saves them in the storage media, ensuring that they are not lost after a reboot.
Scheduled state information report to Cloudnet
The device generates log entries and sends notifications to Cloudnet when state change occurs, allowing Cloudnet to synchronize the device state in the network.
Reading log entries by Cloudnet
Cloudnet reads local log files every 24 hours and stores them in its log folder. Device R&D and service personnel can access these local log files on Cloudnet to monitor device performance. This feature is not available to users and can only be accessed through the Cloudnet gateway.
Command reference
Modified feature: Button for enabling or disabling Cloudnet and UWEB connection
Feature change description
A button was added on the homepage of the local Web interface for users to enable or disable Cloudnet and UWEB connection. With this feature disabled, the device will not actively connect to Cloudnet or respond to UWEB's connection requests.
Command changes
Modified feature: Synchronization of device Web settings with Cloudnet
Feature change description
As from this release, when you configure settings supported by Cloudnet on the local Web interface of a device connected to Cloudnet, the device sends a notification to notify Cloudnet to read device configuration.
Command changes
Modified feature: Cloudnet authentication
Feature change description
A new authentication feature was added. When you bind a device on the Cloudnet Web interface, you must enter the account name and password for verification. The device can be successfully bound only when the account name and password are correct.
When you enter the device serial number, account name, and password on the Cloudnet Web interface, Cloudnet sends the account name and password to IoT for verification. Based on the verification result from IoT, Cloudnet determines whether the device can be successfully bound.
Command changes
None.
R8808
None.
E8807
First release.
Operation changes
Operation changes in R8831P01
None.
Operation changes in R8831
None.
Operation changes in R8829P01
Before modification: The PoE standard of PoE model devices is initialized to af mode by default.
After modification: The PoE standard of PoE model devices is initialized to at mode by default.
Operation changes in R8829
None.
Operation changes in R8828
None.
Operation changes in R8821
None.
Operation changes in R8812
None.
Operation changes in R8808
None.
Operation changes in E8807
Restrictions and cautions
Before upgrading the software, check the software feature changes between versions, assess the potential impact of these changes on your business, and read the related documents.
Restrictions
Hardware
None.
Software
When you shut down the peer port or the port is up, the VCT detection results might be inaccurate. The port might be displayed as in abnormal status, for example, mismatch, disconnected, or short-circuit.
Network configuration
None.
Cautions
Hardware
None.
Software
None.
Network configuration
Open problems and workarounds
202606091249
· Symptom: After you push a large number of port configurations in bulk, the device configurations actually take effect, but the system returns a "Time out" error message.
· Condition: This symptom might occur if you select a large number of ports for batch configuration and deployment in a single operation on the overseas Cloudnet platform.
· Workaround: Select fewer ports in each batch configuration operation.
202606031761
· Symptom: When you check the loop status on the ES4200 device, the information indicates that the port does not enter the blockade state, and no actual traffic storm occurs.
· Condition: This symptom might occur if an iOptic host connects to two ES4200-ES series devices and form a physical loop.
· Workaround: Design your network topology to avoid physical loops.
List of resolved problems
Resolved problems in R8831P01
202511210947
· Symptom: The page loads slowly or fails to load when you log in to the Web page.
· Condition: This symptom occurs if you use Cloudnet to remotely log in to the Web page, and the router’s TCP MSS field value is too low after endian conversion.
Resolved problems in R8831
202512031997
· Symptom: After you enable the anti-tampering feature on the Aolynk cloud platform, the device's uplink port does not automatically become a trusted port.
· Condition: This symptom might occur when the Aolynk cloud platform manages the device and anti-tampering is enabled through the platform.
202604271410
· Symptom: When you run a network test on the device, significant response latency (high ping latency) exists. If the device operates in AON node mode with significant response latency, it will frequently come online and go offline in the AON Ethernet system.
· Condition: This symptom occurs on PoE models.
202604200831
· Symptom: The enabling status of PoE on the local Web interface is inconsistent with that on Cloudnet, where the status error occurs.
· Condition: This symptom might occur if the device is managed by Cloudnet.
202511140551
· Symptom: In standalone mode, changing the default VLAN to the management VLAN causes the device's original IP address to become invalid.
· Condition: The device is in standalone mode. When it is integrated into the iOptic Ethernet networking, the management VLAN used for networking does not match the VLAN where the device currently resides.
202605291567
· Symptom: The forced PoE power supply feature configured on the local Web interface fails to recover to the default disabled state as expected.
· Condition: This symptom might occur if you enable forced PoE power supply and perform a mode switchover.
202512101285
· Symptom: The PoE standard displayed on the device's local web interface is incorrect; the correct one should be AT mode.
· Condition: The device is powered on and running. Log in to the device's local web interface, navigate to the PoE information page, and check the "PoE standard" display.
Resolved problems in R8829P01
202510170524
· Symptom: After the iOptic Host manages the AON node and incorporates it into the analyzer, the analyzer is unable to retrieve optical link data such as ES4200 wavelength, rate, and bandwidth.
· Condition: The device is powered on and running, with the iOptic Host managing the AON node and integrating it into the analyzer.
Resolved problems in R8829
None.
Resolved problems in R8828
202507081734
· Symptom: An AON node (also called iOptic node) failed to upgrade automatically.
· Condition: This symptom occurs if the following conditions are met:
¡ Automatic upgrade for AON nodes is enabled in the AON Ethernet system.
¡ The AON node comes online again after it goes offline because its upgrade process is interrupted by AON aggregation (also called iOptic host) restart, configuration deletion or network disruption.
202506230608
· Symptom: Some AON nodes cannot come online automatically.
· Condition: This symptom might occur if AON nodes go offline in bulk, and then come online in bulk in the AON Ethernet system.
202409250402
· Symptom: Packets with VLAN tags identical to the PVIDs of local ports are not forwarded.
· Condition: This symptom occurs if you configure multiple ports as trunk ports, and some of them have traffic anomalies.
Resolved problems in R8821
None.
Resolved problems in R8812
202406251829
· Symptom: The device is not responding and requests time out.
· Condition: This symptom might occur if the UWEB issues loop prevention configuration.
202406132243
· Symptom: The IP address of the iOptic host is displayed as 0.
· Condition: This symptom might occur if an iOptic node comes online.
202406130892
· Symptom: The time format is incorrect.
· Condition: This symptom might occur on the Web homepage.
202406071855
· Symptom: Failed to delete static MAC addresses. The page prompts an error message.
· Condition: This symptom might occur if you delete static MAC addresses on the Web interface.
202406031607
· Symptom: Failed to delete blackhole MAC addresses.
· Condition: This symptom occurs if you delete dynamic MAC addresses from the MAC address list.
202406030635
· Symptom: Downlink ports cannot forward traffic.
· Condition: This symptom occurs if you disable port isolation.
202405281654
· Symptom: The domain name has failed to be restored to the factory default setting.
· Condition: This symptom occurs if you restore the device to factory defaults.
202405211202
· Symptom: The device cannot come online.
· Condition: This symptom occurs if a self loop exists on the device.
202405160474
· Symptom: No prompt is displayed when you enter an invalid MAC address.
· Condition: This symptom might occur if you enter an invalid MAC address.
202405130172
· Symptom: Incorrect PoE information.
· Condition: This symptom occurs if you log in to the Cloudnet and PoE information is reported to the Cloudnet.
202405100715
· Symptom: Incorrect LLDP neighbor information.
· Condition: This symptom might occur if the device is incorporated by an iOptic host.
202404291242
· Symptom: The returned error message is incorrect.
· Condition: This symptom occurs if you add VLAN 1.
202406140184
· Symptom: Inappropriate password specification.
· Condition: This symptom occurs if you change the password.
202405150817
· Symptom: DHCP snooping has failed to be enabled.
· Condition: This symptom might occur if you enable DHCP snooping on the Cloudnet.
Resolved problems in R8808
202401311607
· Symptom: The device has crashed, and the Web interface for the switch is inaccessible.
· Condition: This symptom occurs if the device connects to Cloudnet in an overseas test environment.
202401171172
· Symptom: Enabling DHCP still allows a client to obtain an IP address after you configure the MAC address of the client or server as a blackhole MAC address.
· Condition: This symptom occurs if you configure the MAC address of the client or server as a blackhole MAC address.
202401311723
· Symptom: The MAC addresses of packets cannot be learned, and traffic cannot be forwarded correctly.
· Condition: This symptom occurs if the VLAN ID in the transmitted packets is 0.
202401311549
· Symptom: A device is unincorporated.
· Condition: This symptom occurs if you create 32 static MAC address entries and then bulk delete all of them on the device.
202401100786
· Symptom: DHCP does not automatically renew leases.
· Condition: This symptom occurs if the IP addresses obtained through DHCP expire.
202401261600
· Symptom: The packet statistics displayed are incorrect.
· Condition: This symptom occurs if you view the traffic statistics on a switch after the switch is incorporated by the iOptic host.
202401250221
· Symptom: The interface speeds displayed are incorrect.
· Condition: This symptom occurs if you view the interface speeds on a switch after the switch is incorporated by the iOptic host.
202403110823
· Symptom: The port mirroring configuration displayed is incorrect.
· Condition: This symptom occurs if you configure port mirroring, delete the configuration, and then reboot the device.
Resolved problems in E8807
First release.
Related documentation
Related documents
· H3C ES4200 Switch Series Installation Guide
· H3C ES4200 Switch Series Hardware Information and Specifications
· H3C S1600V2 Switch Series Installation Guide
· H3C S1600V2 Switch Series Hardware Information and Specifications
· H3C S1600V2_ES4200 Switch Series Web Configuration Guide
Obtaining the documents
To obtain the latest documents:
1. Access http://www.h3c.com/en/Technical_Documents
2. Select the product category and product model. Then, you can query and download documents related to the product.
Technical support
Email: service@h3c.com
Website: http://www.h3c.com/en
See H3C ES4200/S1600V2 Switch Series Installation Guide.
Supported features | ES4200-16T2RX | S1600V2-26S | S1600V2-26S-HPWR | |
MAC address table | Maximum number of addresses supported | 16k | 16k | 16k |
Supported features | 32 static address entries Blackhole MAC address entries MAC address learning and aging | |||
VLAN | 16 port-based VLANs Access/trunk mode configuration | |||
Port management | Rate/duplex mode configuration Flow control Bring up/shutting down ports | |||
PoE | Enabling/disabling PoE for ports Display of total, used, and free power. | |||
IP management | Static IP configuration Address acquisition through DHCP | |||
Upgrade | System upgrade through webpage | |||
Maintenance | Ping operations Restoring factory defaults by one click One-click restart Saving configuration | |||
Port mirroring | Port mirroring configuration | |||
Port isolation | Port isolation | |||
Loop detection and prevention | Loop protection | |||
Cable detection | Cable detection | |||
Port rate limit | Port rate limit | |||
Storm control | Storm control configuration | |||
Buttons | Switchover between normal mode and PoE mode by pressing the mode LED. Press the reset button restarting the device. Press and hold the reset button for 1 to 5 seconds resetting the password. Press and hold the reset button for 5 to 10 seconds restoring the factory defaults. Press and hold the reset button for over 10 seconds restores the device to normal state. | |||
| NOTE: For ease of readability, the capacity and speed units megabits per second (Mbit/s) and gigabits per second are abbreviated as M and G, respectively. |
About device software
The device software mainly includes the boot loader program and the startup software package. After the device starts, it first runs the boot loader program to initialize hardware, and then runs the startup software package. The boot loader program and startup software package are required for the device startup and operation. They provide support, management, and service functionalities for the entire device. Figure 1 shows the relationship between boot loader and startup software package