H3C UniServer R4900 G7 Server Ecodesign Manual-5PW101

HomeSupportServersTechnical DocumentsInstall & UpgradeCompliance and Safety InformationH3C UniServer R4900 G7 Server Ecodesign Manual-5PW101
Download Book
  • Released At: 14-05-2025
  • Page Views:
  • Downloads:
Table of Contents
Related Documents

H3C IT RACK Series Product Information for Ecodesign Requirements of (EU) 2019/424

 

Regulatory Reference: COMMISSION REGULATION (EU) 2019/424, implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to Ecodesign requirements for servers and online data storage products.

Product Type

Server

Manufacturer

New H3C Technologies Co., Ltd

Trade

H3C

Address

No.466 Changhe Road, Binjiang District, Hangzhou, Zhejiang 310052, P.R.China

Product Model

H3C UniServer R4900 G7

Year of Manufacture

2024

 

PSU Efficiency

PSU model

CRPS1600C2

Rated Output

+12.2V/132A,+12VSB/3.0A

Rated Load

10%

20%

50%

100%

PSU Efficiency

93%

95%

96%

91%

Power Factor

0.96

0.99

0.99

0.99

 

PSU model

PSR850-12A

Rated Output

+12V/70.8A,+12VSB/3.0A

Rated Load

10%

20%

50%

100%

PSU Efficiency

92%

95%

96%

94%

Power Factor

0.96

0.97

0.99

0.99

 

PSU model

PS-2162-12L5

Rated Output

+12V/131.20A,+12VSB/2.1A

Rated Load

10%

20%

50%

100%

PSU Efficiency

91%

95%

96%

94%

Power Factor

0.91

0.99

0.99

0.99

 

PSU model

CRPS3200T

Rated Output

+12V/262.3A,+12VSB/3.0A

Rated Load

10%

20%

50%

100%

PSU Efficiency

93%

96%

96%

92%

Power Factor

0.98

0.99

0.99

0.99

 

Note1: DC-DC internal power supplies don’t need to fill in the form.

Note2: External Power Supplies (EPS) are regulated as a separate component in the European Union and a separate compliance document is required for EPSs. Leave Internal Power Supply test data fields blank for products that use an EPS (and that do not use an internal power supply).

 

Idle State Power (W) and Active state efficiency

 

The test for Idle State power and Active State Efficiency is based on ETSI EN 303 470 V1.1.1 (2019-03)- Environmental Engineering (EE); Energy Efficiency measurement methodology and metrics for servers.

Configuration

Idle State Power (W)

Active state efficiency

Low-end performance configuration

196.7

72

High-end performance configuration

195.5

85.9

Note: SERT Active State Efficiency must be higher to pass to table 5 of the Regulation. SERT Idle State Power must be lower than the calculated limit to pass- described in Annex II 2.1 of the Regulation.

 

Components List for additional idle power allowances

 

Low-end performance:

System characteristics

Quantity

Additional Idle Power Allowances

CPU Performance

2

17.5

Additional PSU

2

20

HDD or SSD

2

10

Additional Memory (GB)

1020

183.56

Additional buffered DDR Channel

24

96

Additional I/O devices

0

0

Total additional idle power allowances

/

365.06

 

High-end performance:

System characteristics

Quantity

Additional Idle Power Allowances

CPU Performance

2

14

Additional PSU

2

20

HDD or SSD

2

10

Additional Memory (GB)

1020

183.56

Additional buffered DDR Channel

24

96

Additional I/O devices

0

0

Total additional idle power allowances

/

361.56

 

Maximum Power (W)

 

Configuration

Maximum Power

Low-end performance configuration

1232.86

High-end performance configuration

1334.84

 

Operating Condition Class    

 

 

Dry bulb temp °C

Humidity range, non-condensing

 

 

Operating Condition Class

Allowable Range

Recommended Range

Allowable Range

Recommended Range

Max Dew Point (°C)

Maximum rate of Change (°C/hr)

A4

5-45

18-27

-12 °C DP and 8 % RH to 24 °C DP and 90 % RH

-9 °C DP to 15 °C DP and 60 % RH

24

5/20

 

 

Idle State Power at the higher boundary temperature of the declared operating condition class

 

Configuration

Idle State Power

Low-end performance configuration

196.76

High-end performance configuration

195.54

 

Secure data deletion functionality

 

Instruction on how to use

Copy the script and run it in the OS

Used Techniques

All data covered in the whole disk

Supported standards

DoD 5220.22-M

 

List of all model configurations   

 

Computing

2 Intel® Xeon® 6 Processors

144 Cores for each Processor and 330W power consumption

Memory

32 DDR5 RDIMM Slots, 6400 MT/s Data Rate, 8TB on 2 CPU Configuration with 256G DDR5 RDIMM

Storage

29 Drives

Front 12LFF bays, Rear 4LFF bays

Front 25SFF bays, Rear 4SFF bays

SAS/SATA HDD/SSD Drives, 24 U.2 NVMe Drives, 36 E3.S SSD, 8 E1.S SSD slots

SATA/NVMe M.2 Kit, DSD Model (2 x SD card kit)

4 Drive Tri-Mode Backplan

GPU

10 Single-Slot or 3 Dual-Slot GPU Modules

Note: The configurations of server product family are end-user configurable / selectable, the detail can be found at http://www.h3c.com

 

The Concentration of Cobalt and Neodymium

 

Item

Description

Cobalt in battery

Less than 5g

Neodymium in HDD

between 5 g and 25 g

Disassembly Operations

Operation Type

Description

Data Storage Device

Release buckle

Memory

Release buckle

CPU

Remove Screw

Motherboard

Remove Screw

Expansion/Graphic Card

Remove Screw&Release buckle

PSU

Release buckle

Chassis

Release buckle

Batteries

Release buckle

Fastening technique type

Quantity

Required Tool

Trox Screw

27

Trox Screw Driver T15

Trox Screw

33

Trox Screw Driver T10

Trox Screw

8

Trox Screw Driver T30

Philps Screw

28

Philps Screw Driver #2

Pan Head Screw

3

Pan Head Screw Driver Medium

Buckle

80

/

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网