Supported products
H3C UniServer R3950 G6
Restrictions and guidelines
None.
Version information
Version number
CPLD version: V003
| NOTE: To view the CPLD version of a drive backplane, access the HDM Web interface of the server, navigate to System > Summary > Others page and select the drive backplane, as shown in Figure 1 The figure is for illustration only. After upgrading to version V003,Module model: RS46B04SUF,Part number: 0302A8A7, CPLD version: V003 |
Figure 1 Viewing CPLD version


Table 2 Version history
Version number | Last version | Release date | Version type | Remarks |
V003 | V002 | 2025-08-11 | Release version | None. |
V002 | V001 | 2024-07-29 | Release version | None. |
V001 | First release | 2024-06-18 | Release version | None. |
Supported languages
English.
Chinese.
Supported hardware platforms
Table 3 Supported hardware platforms
Product Series | PUID |
H3C UniServer R3950 G7 | R3950-G7-MAS0 R3950-G7-MAL0 |
H3C UniServer R4950 G7 | R4950-G7-MAS0 R4950-G7-MAL0 |
H3C UniServer R3350 G7 | R3350-G7-MAL0 |
H3C UniServer R4950 G6 | |
H3C UniServer R3950 G6 | |
Hardware and software compatibility matrix
| CAUTION: To avoid an update failure, use the following table to verify the hardware and software compatibility before performing an update. |
Table 4 Hardware and software compatibility matrix for H3C UniServer R4950 G6
Item | Specifications |
Product family | H3C UniServer R4950 G6 |
MCPLD | V00B or later |
SCPLD | V00B or later |
VR | V003 or later |
HDM | 1.72 or later |
BIOS | 6.30.40 or later |
Image file name and MD5 value | RS4B04SUFA002.bin:99101db06f91f1c6e37c2c4532c4ad69 RS4B04SUFA002_00.jed:0bea11eb40958da57d3f9bf58ed609d9 (Subject to change according to the latest naming conventions) |
Remarks | N/A. |
Update recommendation
This version is required for update.
Update restrictions and guidelines
Make sure the server and the HDM client (such as a PC) can reach each other.
For a successful bulk update, make sure you can update one server successfully before you update the remaining servers.
During the update, make sure the network connection is available and do not refresh the webpage.
Do not refresh the page during the update.
To avoid CPLD or operating system errors, do not power on or power off the server during the firmware update.
After the firmware is updated, clear the browser cache before you re-log in to HDM.