Version:6.30.42(2025/9/26)
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.30.42
Symptom: After disabling the memory module in setup, the corresponding memory under North Bridge shows "not present" instead of the expected "disabled".
Condition: Disabling the memory module in setup.
Symptom: When out-of-band (OOB) SOL redirect is enabled, the BIOS Setup interface displays abnormally in Chinese mode.
Condition: Enabling OOB SOL redirect and setting the language to Chinese.
Symptom: The upper limit of the BIOS-allowed RTC time-range (TRANGE) has been adjusted to 2099.
Condition: There is a requirement to adjust the upper limit of the BIOS-allowed RTC TRANGE to 2099.
Symptom: On the SOL and BIOS serial port redirect output page, the Console Redirections EMS option is displayed incompletely.
Condition: SOL output and serial port redirection under the BIOS serial port.
New Functions
Upgrade recommendations
recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.30.39
Symptom: The default PK for Secure Boot in the BIOS must use the one generated by H3C BIOS. The test PK provided by IBV must be removed.
Condition: This symptom might occur if the PK update for Secure Boot is required.
Symptom: When you import the customization package with the Enable Requested CPU min frequency and Requested CPU min frequency items set to non-default values, these items fail to be customized.
Condition: This symptom might occur if the customization package customizes the Enable Requested CPU min frequency and Requested CPU min frequency items.
Symptom: For the Moore S5000 module to be compatible with the R5500 G6 8U liquid-cooled model, you must enable Resizable Bar in the BIOS.
Condition: This symptom might occur if the R5500 G6 8U liquid-cooled model is installed with the Moore S5000 module.
Symptom: When the physical power button is pressed to start the server within a short period of time after the power source is connected, BMC does not finish starting, causing the BIOS to be unable to obtain a valid OEM flag to enter the load default process. This results in the BIOS value not matching the customized value.
Condition: This symptom might occur if the physical power button is pressed to start the server within a short period of time after the power source is connected, causing the BIOS to start up before the BMC finish startup.
Symptom: MBIST fails to report socket numbers from 1.
Condition: This symptom might occur if you enable MBIST and view the location information of the faulty memory reported by MBIST.
New Functions
Upgrade recommendations
recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.30.35P01
Symptom: When you use IPMI SOL Activate to connect to the BF3 cloud drive system from the HDM IP, input and output commands experience abnormal lag.
Condition: This symptom might occur if you use Ubuntu 22.04 and view the OS boot log via SOL.
New Functions