Home Support Resource Center Software Download Servers

R6700 G3 HDM(2020/5/27)

Category-Component Type:

Firmware-HDM

Version:

B03 1.30.20

OS:

N/A-N/A

    Description

  • Description
  • Installation steps
  • Publish Description
  • Problems Solved
  • New Functions
  • Historical Versions
  • Description

  • Installation steps

  • Publish Description

  • Problems Solved

  • New Functions

  • Version:3.54(2025/4/15)

    Upgrade recommendations

    optional for upgrade

    Problems Solved

    Resolved problems in HDM-3.54

    202502271930

    Symptom: HDM fails to open Java KVM.

    Condition: This symptom might occur if you open Java KVM from HDM.

    202502171748

    Symptom: Repeatedly creating and closing SOL sessions on HDM causes HDM to fail in creating a new SOL session.

    Condition: This symptom might occur if you repeatedly create and close SOL sessions.

    New Functions

    HDM-3.54

    N/A

    Version:3.49.01(2024/9/24)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.49.01

    202405141974

    Symptom: The server's input and output power values obtained through the Redfish interface are the same.

    Condition: This symptom might occur if you use the Redfish interface to obtain the power values for a server installed with an Intel processor.

    202408230652

    Symptom: When you change the user password through the HDM web page, if the ID in the interface URL and the ID in the BODY are inconsistent, the change can still succeed.

    Condition: This symptom might occur if the ID in the interface URL and the ID in the BODY are inconsistent when you change the user password through the HDM web page.

    202406191302

    Symptom: The R4900 G5 server intermittently shows the hard drive status as Ready.

    Condition: This symptom might occur if you configure logical drives under a PMC storage controller for an R4900 G5. The status of member drives of the logical drives might change to Ready.

    202407070061

    Symptom: After the server runs for a period, SDS logs cannot be downloaded via HDM, leading to repeated HDM reboots.

    Condition: This symptom might occur after the server runs for a period.

    New Functions

    HDM-3.49.01

    HDM-3.49.01 added support of the following hardware options for the R5300 G5:

    Enflame S60 GPU

    HDM-3.49.01 added support of the following hardware options for the R4900 G5:

    NS8500 G2 1.92&3.2&7.68TB SSD 

    HDM-3.49.01 added support of the following hardware options for the R4950 G5:

    SSD-7.68T-NVME-CD8P

    SSD-7.68T-NVME-7940M

    HDM-3.49.01 added support of the following hardware options for the R4930 G5 H3:

    SSD-1.92T-NVME-J5100

    Version:3.48(2024/7/15)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.48

    Symptom: The B5700 G5 failed to interconnect with the OM module after historical passwords are disabled on BMC for the B5700 G5.

    Condition: This symptom might occur if historical passwords are disabled on BMC for the B5700 G5.

    Symptom: A service alarm occurs on the server due to I/O delays.

    Condition: This symptom might occur if the LSI storage controller is configured and CC inspection is enabled in an in-band manner.

    Symptom: You can create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface. If the number of RAID arrays exceeds eight, the creation might fail, causing the storage process to get stuck.

    Condition: This symptom might occur if you create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface, but the number of RAID arrays exceeds eight.

    Symptom: The Redfish library failed to use the BMC interface to obtain part of performance indexes incorrectly.

    Condition: This symptom might occur if the Redfish library uses the BMC interface to obtain power output consumption.

    New Functions

    HDM-3.48

    HDM-3.48 added support of the following hardware options for the R4900 G5:

    QLE2694-SR-AK 16G FC-HBA

    ScaleFlux CSD 3320 3.84TSSD

    HDM-3.48 added support of the following hardware options for the R4950 G5:

    Hanbo GPU VG1000-32G-LP

    Version:3.41(2023/10/31)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.41

    Symptom: When the password validity is set on the server, hREST cannot obtain the related information.

    Condition: This symptom might occur when the password validity is set on the server.

    Symptom: When drives are installed to the R4900 G5 with the 8SFF UniBay drive backplane, the drive locations displayed on HDM do not match the actual configurations.

    Condition: This symptom might occur if the R4900 G5 is installed with 8SFF UniBay drive backplane.

    Symptom: When an ADDDC error occurs, the server does not report the corresponding log information.

    Condition: This symptom might occur if an ADDDC error occurs on the server.

    Symptom: When the server is installed with a PCIe module that has MB in its name and an error occurs on the PCIe module, MCA suggests replacing the module. However, HDM shows a critical alarm on the system board.

    Condition: This symptom might occur if the server is installed with a PCIe module that has MB in its name and an error occurs on the PCIe module.

    Symptom: An SEL alarm of system detected the absence of a DIMM was mistakenly reported on the R5500 G5.

    Condition: This symptom might occur if a G5 Intel sever is installed with non-certified DIMMs and is restarted.

    New Functions

    HDM-3.41

    HDM-3.41 added support of the following hardware options for the R4900 G5:

    Solidigm P5520 15.36T drive

    Great Wall 2700W power supply

    IVA-CP24-VA

    HDM-3.40 added support of the following hardware options for the R4950 G5:

    Configuration only with the rear 4SFF UniBay drive backplane

    HDM-3.40 added support of the following hardware options for the R5300 G5:

    Iluvatar V100 (MR) GPU

    Version:3.40(2023/10/7)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.40

    Symptom: When there is a partial power failure in the R4900 G3 server, the health LED turns red, and there are no alarm messages displayed on the HDM webpage.

    Condition: The symptom might occur when there is a partial power failure in the R4900 G3 server.

    Symptom: In R4930 G5 H3 servers with multiple drive backplanes, there is a low probability of receiving drive fault and missing alarm logs on HDM during the host startup process.

    Condition: The symptom might occur when R4930 G5 H3 servers are configured with multiple drive backplanes, and there is a low probability of receiving false disk alarms on HDM during the host startup process.

    Symptom: When performing fieldiag on R5500 G5 servers, there is a random occurrence of errors.

    Condition: The symptom might occur when R5500 G5 servers are paired with a specific version of HDM and fieldiag is executed in-band.

    New Functions

    HDM-3.40

    HDM-3.40 added support of the following hardware options for the R4900 G5:

    95 series storage controllers for 12LFF+2SFF UniBay configuration

    9560-8i storage controller for 8UniBay configuration

    HDM-3.40 added support of the following hardware options for the R4930 G5 H3:

    NIC-ETH-3S930-LP-2*100G

    HDM-3.40 added support of the following hardware options for the R5500 G5:

    NVIDIA A800 HGX 40G module

    Version:3.39(2023/9/11)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.39

    Symptom: Ucenter reports Unknown state of logical drives when the R4900 G3 is installed with LSI RAID controllers.

    Condition: This symptom might occur when the R4900 G3 is installed with LSI RAID controllers.

    Symptom: The physical view tab of the storage management page displays additional drive presence information when the R4900 G3 uses the 24 NVMe drive configuration.

    Condition: This symptom might occur when the R4900 G3 uses the 24 NVMe drive configuration.

    Symptom: When the R4300 G5 is installed with drives of multiple types, it takes a long time for SNMP WALK to obtain drive information.

    Condition: This symptom might occur when the R4300 G5 is installed with drives of multiple types.

    Symptom: When a G3/G5 server is installed with two LSI HBA modules, such as 9500-8i+ 9300-8i, the system reports Drive Fault alarms mistakenly.

    Condition: This symptom might occur when a G3/G5 server is installed with two LSI HBA modules, such as 9500-8i+ 9300-8i.

    Symptom: When the R5500K installed with an OCP network restarts after a stress test, the system reports OCP overtemperature alarms in bulk.

    Condition: This symptom might occur if you install an OCP network adapter on the R5500K, perform a stress test, and restart the DC power.

    Symptom: Heat dissipation issues occur on the R5500 G5 installed with a 332A network adapter. 

    Condition: This symptom might occur on the R5500 G5 when a 332A intelligent network adapter is installed and the system enters FAKE S5.

    New Functions

    HDM-3-39

    HDM-3.39 added support of the following hardware options for the R5300 G5:

    Nvidia H800 GPU

    Nvidia L40S GPU

    RG800 Pro GPU

    HDM-3.39 added support of the following hardware options for the R4930 G5 (H3):

    GPU-RG800-32GB-FHFL

    25SFF drive backplane PCA-BP-25SFF-2U-G5 used together with NVMe drives

    HDM-3.39 added support of the following hardware options for the R4950 G5:

    UN-RC-2FHFL-R3-2U-G5

    Version:B05 3.18(2022/10/8)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 3.11(2022/7/11)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 3.10(2022/6/14)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 2.98(2022/4/12)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 2.91(2022/1/11)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 2.86(2021/12/7)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 2.81(2021/11/2)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 2.70(2021/8/26)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 2.60(2021/8/2)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 2.57(2021/7/20)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B05 2.43(2021/5/31)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.30(2021/3/29)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.28(2021/1/20)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.27(2021/1/4)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.26P01(2020/11/27)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.23(2020/8/26)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.22(2020/7/29)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.21(2020/6/22)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.20(2020/5/27)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B03 1.30.19(2020/4/30)

    Upgrade recommendations

    Problems Solved

    New Functions

    Version:B02 1.11.35P06(2020/2/21)

    Upgrade recommendations

    Problems Solved

    New Functions