• Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
Home Support Resource Center Software Download Servers

R4900 G6 Ultra BIOS(2025/9/22)

Category-Component Type:

Firmware-BIOS

Version:

6.10.55

OS:

N/A-N/A

    Description

  • Description
  • Installation steps
  • Publish Description
  • Problems Solved
  • New Functions
  • Historical Versions
  • Description

    This software is used to upgrade the BIOS version of the R4900 G6 Ultra server

  • Installation steps

  • Publish Description

    Supported products

    H3C UniServer R4900 G6 Ultra

    Restrictions and cautions

    Restrictions

    The configuration import function is not available for upgrading the BIOS from a lower version to BIOS-6.00.20 and higher on HDM due to compatibility issues, but is available for upgrades from BIOS-6.00.20 and higher.

    To avoid server startup errors, do not use the AFU tool to downgrade the BIOS from BIOS-6.10.XX to BIOS-6.00.XX with the user-configured settings retained.

    BIOS-6.00.XX does not support EMR processor upgrade or downgrade on dual-processor servers.

    Guidelines

    To avoid BIOS boot failures, do not upgrade or reset HDM during BIOS boot.

    If the system encounters a black screen and cannot boot after the BIOS firmware upgrade and restart, it may be caused due to the HDM firmware not being compatible. To resolve this issue, upgradeHDM to the version of the corresponding model as shown in Table 8.

    Table 8 HDM firmware version for servers

    Product model

    HDM firmware version

    H3C UniServer R4900 G6 Ultra, R4900/R4900LE G6, R4700/R4700LE G6

    HDM2-1.24 or later

    H3C UniServer R5300 G6/R5500 G6(Intel)/R6700 G6/R6900 G6

    HDM2-1.60 or later 

    H3C UniStor X10000 G6/X18000 G6

    HDM2-1.63 or later 

     

    As from the BIOS-6.10.48 for R6700 G6/R6900 G6, the signed firmware version is expanded to 81 M and requires an update in conjunction with HDM2-1.74 or above.

    If a server equipped with Intel S4510 & S4520 SATA M.2 SSDs loses drives after a DC cold reboot, update the BIOS firmware to version 6.10.43 or later and perform an AC power cycle.

    Version information

    Version number

    Version 6.10.55

    Table 1 Target file name and MD5 checksum

    Model

    File name and MD5 checksum

    H3C UniServer R4500 G6/R4900 G6 Ultra/R4900 G6/R4900LE G6, R4700/R4700LE G6

    C35-BIOS-6.10.55-signed.bin: 55fa86e170d5cdc4a5625ad03c1b7085

     

    You can access the HDM Web interface of the server to identify the BIOS firmware version in the Device information section of the Dashboard > Summary page, as shown in Figure 1.

    Figure 1 Viewing the BIOS version number from HDM

    图片 1

     

    BIOS built-in software version

    Table 2 EMR&SPR CPU BIOS built-in software version

    Item

    Version

    Microcode

    EMR Production A* / R* Step: m_87_c06f2_210002a9.pdb;
    ‎SPR Production E* / S* Step: m_87_806f8_2b000639.pdb;
    ‎SPR HBM Production B* Step: m_10_806f8_2c0003f7.pdb;

    Intel BKC version

    IPU 2025.2 WW13_2025

    RC code

    114.D30

    ME firmware

    SPS_E5_06.01.04.089.0

    RSTe PreOS components

    v9.0.0.2018

    VMD VROC

    v9.0.0.2018

    BIOS ACM

    v1.1.A

     

    Supported languages

    English

    Chinese

    Supported devices

    H3C UniServer R4500 G6

    H3C UniServer R4700 G6

    H3C UniServer R4700LE G6

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4900LE G6 Ultra

    H3C UniServer R4900LE G6

    Hardware and software compatibility matrixes

    CAUTION:

    To avoid update failure, verify the hardware and software compatibility before performing an update.

     

    Table 3 Hardware and software compatibility matrix for H3C UniServer R4500 G6

    Item

    Specifications

    Product family

    H3C UniServer R4500 G6

    HDM

    HDM2-2.08 and later

    CPLD

    V002 and later

    iMC

    N/A

     

    Table 4 Hardware and software compatibility matrix for H3C UniServer R4900 G6 Ultra/R4700 G6

    Item

    Specifications

    Product family

    H3C UniServer R4900 G6 Ultra/R4700 G6

    HDM

    HDM2-1.74 and later

    HDM2-2.12 and later

    CPLD

    V005 and later

    iMC

    N/A

     

    Table 5 Hardware and software compatibility matrix for H3C UniServer R4900 G6

    Item

    Specifications

    Product family

    H3C UniServer R4900 G6

    HDM

    HDM2-1.74 and later

    HDM2-2.12 and later

    Phytium E2000:HDM3-1.15 and later

    CPLD

    CPLD1:V004 and later

    CPLD2:V004 and later

    Phytium E2000 CPLD:V001 and later

    iMC

    N/A

     

    Table 6 Hardware and software compatibility matrix for H3C UniServer R4900LE G6 Ultra/R4700LE G6

    Item

    Specifications

    Product family

    H3C UniServer R4900LE G6/R4700LE G6 

    HDM

    HDM2-1.74 and later

    HDM2-2.12 and later

    CPLD

    V002 and later

    iMC

    N/A

     

    Table 7 Hardware and software compatibility matrix for H3C UniServer R5500 G6 (Intel)

    Item

    Specifications

    Product family

    H3C UniServer R5500 G6 (Intel)

    HDM

    HDM2-1.84 and later

    HDM2-2.21 and later

    CPLD

    003 and later

    iMC

    N/A

     

    Update suggestions

    This version is optional.

    Update restrictions and guidelines

    Make sure the software versions are compatible with each other.

    To update both HDM and the BIOS, update HDM first.

    Make sure the server is running in stable state before the update. That is, the server is powered off or has entered the operating system.

    If the server enters the OS before the update, you must power cycle the server for the new firmware to take effect.

    If you select the Retain or Restore method to update the BIOS, the update occurs during POST after the server is powered on again. During the update, do not disconnect the power source from the server, or forcedly power off or restart the server.

    If you select the Forcedly restore method to update the BIOS, do not disconnect the power source from the server, or power off or restart the server.

    Selecting the Restore or Forcedly restore method will restore the default BIOS settings, including restoring the boot mode in the BIOS to the default (UEFI).

    During BIOS update with Forcedly restore selected, writing BIOS data, such as restarting the system or saving BIOS configuration from the BIOS setup utility, can cause data write errors. This can lead to BIOS ROM integrity check failures and even system starting failures. If the system prompts Flash Image Broken! System Halt!, forcedly power off the server, and then try to update the BIOS with Forcedly restore selected again.

    As a best practice of bulk update, make sure you can update one server successfully before you update the remaining servers.

  • Problems Solved

    Resolved problems in BIOS-6.10.55

    202507281217

    Symptom: The system fails to obtain the speed of the NIC-ETH360T-3S-4P network adapter during BIOS initialization.

    Condition: This symptom might occur if you view the network adapter speed during BIOS initialization.

  • New Functions

  • Version:6.10.55(2025/9/22)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.55

    202507281217

    Symptom: The system fails to obtain the speed of the NIC-ETH360T-3S-4P network adapter during BIOS initialization.

    Condition: This symptom might occur if you view the network adapter speed during BIOS initialization.

    New Functions

    Version:6.10.54(2025/8/4)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.54

    202404260775

    Symptom: The OCP2 slot cannot enter PXE in Legacy mode.

    Condition: None.

    New Functions

    Version:6.10.53(2025/6/24)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.53

    202504251479

    Symptom: After you set Workload Profile Config to Fixed Turbo Frequency, setting Static Turbo to Auto will cause Fixed Turbo Frequency to fail to lock the turbo frequency.

    Condition: This symptom might occur if you Static Turbo to Auto after setting Workload Profile Config to Fixed Turbo Frequency.

    New Functions

    Version:6.10.51(2025/4/17)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.51

    202502240494

    Symptom: A memory fault in the server triggered a CPU DCU alarm, but the DCU alarm information cannot be parsed. The SEL did not report the specific memory slot.

    Condition: This symptom might occur if a memory fault in the server triggered a CPU DCU alarm.

    202501130827

    Symptom: The serial number of the specified CXMT memory module displayed in HDM does not match the information shown in the BIOS Setup interface.

    Condition: This symptom might occur if you view the serial number of a CXMT memory module in HDM.

    New Functions

    Version:6.10.49P01(2025/3/17)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.49P01

    202502120331

    Symptom: When the server is installed with the KUNLUNXIN P800 GPU, the GPU configuration menu correctly in the BIOS setup utility.

    Condition: This symptom might occur if you view GPU information in the BIOS setup utility when the server is installed with the KUNLUNXIN P800 GPU.

    New Functions

    Version:6.10.49(2025/2/18)

    Upgrade recommendations

    Optional upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.49

    202412110375

    Symptom: The SEL does not clearly display the reasons for DIMM disabling caused by PMIC errors.

    Condition: This symptom might occur if DIMMs are disabled due to PMIC errors.

    202412201719

    Symptom: When the R5500 G6 is installed with MT S5000 GPUs, the system failed to download the GPU driver in BIOS-6.10.47.

    Condition: This symptom might occur if the system attempts to download the GPU driver in BIOS-6.10.47 when the R5500 G6 is installed with MT S5000 GPUs.

    New Functions

    Version:6.10.47(2024/12/4)

    Upgrade recommendations

    Upgrade recommended

    Problems Solved

    Resolved problems in BIOS-6.10.47

    202410221416

    Symptom: When a GPU server model is installed with the P800 GPU, the BIOS dynamically changes the Re-size BAR support option to Enable.

    Condition: This symptom might occur if the P800 GPU is installed.

    202410210576

    Symptom: When a GPU server model is installed with the P800 GPU, the BIOS dynamically changes the MMIO High Granularity option to 1.

    Condition: This symptom might occur if the P800 GPU is installed.

    202410140915

    Symptom: When the R5300 G6 server is configured with the X32 Switch board, OCP network adapters and 12LFF drives, the BIOS displays slot numbers of OCP network adapters incorrectly.

    Condition: This symptom might occur if you view slot numbers of OCP network adapters on the R5300 G6 server configured with the X32 Switch board, OCP network adapters and 12LFF drives.

    New Functions

    Version:6.10.45(2024/9/24)

    Upgrade recommendations

    optional Upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.45

    Symptom: After you update the BIOS firmware to version 6.10.43 on the server with the ATS2600 BMC VA card, the BIOS setup utility gets stuck, which affects normal operations.

    Condition: This symptom might occur if you update the BIOS firmware to version 6.10.43 on the server with the ATS2600 BMC VA card.

    Symptom: When the R5500 G6 server with different GPU modules restarts into PXE, IEH-related alarms are reported.

    Condition: This symptom might occur if the R5500 G6 server with different GPU modules restarts into PXE.

    Symptom: The R5500 G6 server has different PE port orders when it is installed with EMR CPUs and SPR CPUs.

    Condition: This symptom might occur if you view the PE port order on the R5500 G6 server installed with EMR CPUs.

    New Functions

    Version:6.10.43(2024/8/9)

    Upgrade recommendations

    optional Upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.43

    Symptom: A server equipped with Intel S4510 & S4520 SATA M.2 SSDs loses drives after a DC cold reboot. You can update the BIOS firmware to version 6.10.43 or later and perform an AC power cycle to resolve the issue.

    Condition: This symptom might occur after you perform a DC cold reboot on a server.

    Symptom: A processor UCE alarm occurs when you restore the NUMA option to the default through IPMI in an out-of-band manner.

    Condition: This symptom might occur if you issue an IPMI command to clear CMOS.

    Symptom: When the server memory configuration supports enabling SGX, change the SGX option from Disable to Enable. After you save the configuration and restart the server, the SGX option is not displayed.

    Condition: This symptom might occur if you change the SGX option when the server memory configuration supports enabling SGX.

    Symptom: Bandwidth loss might occur if you perform stress test on some network adapters in the server.

    Condition: This symptom might occur if you perform stress test on some network adapters when these network adapters are connected to the server.

    Symptom: HDM displays different bandwidth information when Lynxi GPUs are connected to the R5300 G6 in different methods.

    Condition: This symptom might occur if you view bandwidth information from HDM when Lynxi GPUs are connected to the R5300 G6 server in different methods.

    New Functions

    Version:6.10.42(2024/7/4)

    Upgrade recommendations

    optional Upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.42

    Symptom: If EMR CPUs are installed on a dual-processor server, the Processor and Stepping information in the BIOS Setup are displayed as Unknown.

    Condition: This symptom might occur if EMR CPUs are installed on a dual-processor server.

    Symptom: The BIOS passes a fixed memory width value to the BMC, which needs to be adjusted based on the memory installation configuration.

    Condition: None.

    Symptom: Added support for Lynxi HP280 GPUs.

    Condition: None.

    New Functions

    Version:6.10.38(2024/6/14)

    Upgrade recommendations

    optional Upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.38

    Symptom: Opened the Sharelink feature in the BIOS Setup Utility.

    Condition: None.

    New Functions

    Version:6.10.36(2024/6/14)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.36

    Symptom: In legacy mode, entering the BIOS setup utility might result in screen flickering for one to two seconds.

    Condition: This symptom might occur if you enter the BIOS setup utility in legacy mode.

    Symptom: When the server is configured with 5x8 DDR5 memory settings, the Rank Type option on the Advanced > Socket Configuration > Memory Configuration > Memory Topology page displays 10x4 in the BIOS setup utility.

    Condition: This symptom might occur if you enter the BIOS setup utility for the server configured with 5x8 DDR5 memory settings.

    New Functions

    Version:6.10.41(2024/6/3)

    Upgrade recommendations

    optional Upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.41

    Symptom: The Post interface displays memory information in MHz instead of MT/s.

    Condition: This symptom might occur if you view the memory rate from the BIOS Setup Utility.

    New Functions

    Version:6.10.39P01(2024/5/13)

    Upgrade recommendations

    optional Upgrade

    Problems Solved

    Resolved problems in BIOS-6.10.39P01

    Symptom: When the server is equipped with a dual-cloud disk BF3 intelligent network adapter and boots to BIOS Setup, NVMe cloud disks can be recognized but Virtio cloud disks cannot be recognized.

    Condition: This symptom might occur when the server is equipped with a dual-cloud disk BF3 intelligent network adapter and boots to BIOS Setup.

    New Functions

    Version:6.00.34(2024/1/4)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-6.00.34

    Symptom: For the key management module and shared network switch in the BIOS setup utility, some of their functions might fail to switch between Chinese and English when you press the hotkeys F3 and F2 to switch between the two languages.

    Condition: This symptom might occur for the key management module and shared network switch in the BIOS setup utility when you press the hotkeys F3 and F2 to switch between Chinese and English.

    Symptom: When you disable the disk boot option and enter the OS through a new boot option created at the same path, restart and enter the BIOS. As a result, the original disabled boot option is enabled again.

    Condition: This symptom might occur if you disable the disk boot option and enter the OS through a new boot option created at the same path.

    Symptom: When a USB LAN is connected to the network cable and PXE poll is performed in Legacy mode, the USB LAN cannot enter PXE.

    Condition: This symptom might occur if PXE poll is performed in Legacy mode when you connect a USB LAN to the network cable.

    New Functions

    Version:6.00.32(2023/11/30)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-6.00.32

    Symptom: If the server is equipped with a PCIe card with the speed reduction function, after you restart the server and enter the BIOS, no accompanying log is reported by the SDS.

    Condition: This symptom might occur if you restart a server equipped with a PCIe card with the speed reduction function.

    Symptom: The units of the Memory Frequency options are different in Chinese and English versions.

    Condition: This symptom might occur if you view the Memory Frequency options in Chinese and English versions.

    New Functions

    Version:6.00.27(2023/8/30)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in BIOS-6.00.27

    Symptom: The help information for the Intel VT for Directed I/O option in the BIOS setup utility is inaccurate and needs to be modified.

    Condition: This symptom might occur if you view the help information for the Intel VT for Directed I/O option in the BIOS setup utility.

    Symptom: The system prompts an error message when you assign a static address to the IPv4 dedicated or shared network port on the BIOS setup utility in graphic mode.

    Condition: This symptom might occur if you assign a static IP address to the IPv4 dedicated or shared network port.

    Symptom: When you log in to the BIOS as a user with the user role and navigate to Server > BMC Network Configuration > IPv4/IPv6 Network Configuration, the Save button is not greyed out.

    Condition: This symptom might occur if you log in to the BIOS as a user with the user role, navigate to Server > BMC Network Configuration > IPv4/IPv6 Network Configuration.

    Symptom: In Legacy mode, when USB Boot is disabled in the BIOS setup utility and PXE is specified as a one-time boot option, the system enters the USB drive interface after polling.

    Condition: This symptom might occur if USB Boot is disabled in the BIOS setup utility and PXE is specified as a one-time boot option for polling in Legacy mode.

    New Functions

    Version:6.00.23(2023/7/17)

    Upgrade recommendations

    Problems Solved

    Resolved problems in BIOS-6.00.23

    Symptom: Passwords are set for both regular SATA drives and TCG-enabled drives. On graphic-mode BIOS setup utility, when the password box for TCG-enabled drives first appear during server startup, the screen is stuck after you enter the corresponding password and slide the mouse.

    Condition: This symptom might occur if you enter the corresponding password when passwords are set for both regular SATA drives and TCG-enabled drives and the password box for TCG-enabled drives first appear during server startup on graphic-mode BIOS setup utility.

    Symptom: When you disable Hard Disk boot option in Legacy mode, save and restart the server, and then switch back to Legacy mode from UEFI mode, the Boot Override filed still displays Hard Disk.

    Condition: This symptom might occur if you disable Hard Disk boot option in Legacy mode, save and restart the server, and then switch back to Legacy mode from UEFI mode.

    Symptom: After you enable serial port console redirection in Legacy mode on the graphic-mode BIOS setup utility, the drive password box does not display the drive model number in the serial output.

    Condition: This symptom might occur if you enable serial port console redirection in Legacy mode on the graphic-mode BIOS setup utility, and then view the drive password box in the serial output.

    New Functions

新华三官网