Version:2.21.02(2025/8/15)
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in HDM2-2.21.02
Symptom: When equipped with an FC-HBA-LPe31000, the server experiences high fan speed issues due to failure in obtaining the card's temperature.
Condition: This symptom might occur if the server is equipped with an FC-HBA-LPe31000.
New Functions
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in HDM2-2.20
Symptom: After you configure the QQ SMTP server on HDM, an email reception alarm occurs.
Condition: This symptom might occur after you configure the QQ SMTP server on HDM.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM2-2.19
Symptom: After you restart the server and perform a stress test on network adapter information obtaining, the IPv4 address of the shared network port cannot be accessed.
Condition: This symptom might occur if you restart the server and then perform a stress test on network adapter information obtaining.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM2-2.18.01
Symptom: JAVA KVM failed to open from HDM with a message indicating that certificate verification failed.
Condition: This symptom might occur if you open JAVA KVM from HDM.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM2-2.17
Symptom: When syslog settings are configured on HDM, a memory leakage issue occurs on HDM.
Condition: This symptom might occur if HDM is unable to reach the remote syslog server but sends notifications to the remote syslog server for an extended period
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM2-2.16
Symptom: When you upgrade the Retimer firmware but do not restart HDM after this upgrade, and then upgrade the Retimer firmware again, the system prompts an upgrade success. However, the second upgrade actually fails.
Condition: This symptom might occur if you upgrade the Aries Retimer module on the R5500 G6 Intel server but do not restart HDM after this upgrade, and then upgrade the Retimer firmware again.
Symptom: After you configure SMTP, the system fails to send an SMTP test email.
Condition: This symptom might occur if the username for the SMTP email server is specified in Base64 format.
Symptom: You can create a RAID 10 logical drive for the LSI-9460-8i storage controller on the Web interface. If more than eight RAID arrays are created, the creation might fail and the storage process might get stuck.
Condition: This symptom might occur if you create a RAID 10 logical drive for the LSI-9460-8i storage controller on the Web interface, but more than eight RAID arrays are created.
Symptom: When the server is configured with the BF3210E intelligent network adapter, HDM might fail to obtain the POST status of the network adapter during the BIOS boot process. After you enter the operating system, fluctuation issues might occur when you use IPMI commands to obtain the POST status of the network adapter. If the startup of the network adapter times out, the system might fail to report alarm logs.
Condition: This symptom might occur if the server is installed with the BF3210E intelligent network adapter.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM2-2.15
Symptom: HDM does not display the remaining life for Samsung PM1653-SSD drives installed on the server.
Condition: This symptom might occur if the server is installed with Samsung PM1653-SSD drives.
Symptom: Unexpected power-off occurs on the BF3 intelligent network adapter if the R4950 G6 server is installed with a BF3 intelligent network adapter and is enabled with S5 power supply.
Condition: This symptom might occur if the power-off command is issued during the host startup process when the R4950 G6 server is installed with a BF3 intelligent network adapter and is enabled with S5 power supply.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM2-2.14
Symptom: HDM might restart and generate log messages about BMC warm reset.
Condition: This symptom might occur if you run the IPMI script in the OS in an in-band manner and upgrade HDM in an out-of-band manner at the same time.
New Functions