Version:6.10.55(2025/9/22)
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in BIOS-6.10.55
Symptom: The system fails to obtain the speed of the NIC-ETH360T-3S-4P network adapter during BIOS initialization.
Condition: This symptom might occur if you view the network adapter speed during BIOS initialization.
New Functions
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in BIOS-6.10.54
Symptom: The OCP2 slot cannot enter PXE in Legacy mode.
Condition: None.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.53
Symptom: After you set Workload Profile Config to Fixed Turbo Frequency, setting Static Turbo to Auto will cause Fixed Turbo Frequency to fail to lock the turbo frequency.
Condition: This symptom might occur if you Static Turbo to Auto after setting Workload Profile Config to Fixed Turbo Frequency.
New Functions
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in BIOS-6.10.51
Symptom: A memory fault in the server triggered a CPU DCU alarm, but the DCU alarm information cannot be parsed. The SEL did not report the specific memory slot.
Condition: This symptom might occur if a memory fault in the server triggered a CPU DCU alarm.
Symptom: The serial number of the specified CXMT memory module displayed in HDM does not match the information shown in the BIOS Setup interface.
Condition: This symptom might occur if you view the serial number of a CXMT memory module in HDM.
New Functions
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in BIOS-6.10.49P01
Symptom: When the server is installed with the KUNLUNXIN P800 GPU, the GPU configuration menu correctly in the BIOS setup utility.
Condition: This symptom might occur if you view GPU information in the BIOS setup utility when the server is installed with the KUNLUNXIN P800 GPU.
New Functions
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in BIOS-6.10.49
Symptom: The SEL does not clearly display the reasons for DIMM disabling caused by PMIC errors.
Condition: This symptom might occur if DIMMs are disabled due to PMIC errors.
Symptom: When the R5500 G6 is installed with MT S5000 GPUs, the system failed to download the GPU driver in BIOS-6.10.47.
Condition: This symptom might occur if the system attempts to download the GPU driver in BIOS-6.10.47 when the R5500 G6 is installed with MT S5000 GPUs.
New Functions
Upgrade recommendations
Upgrade recommended
Problems Solved
Resolved problems in BIOS-6.10.47
Symptom: When a GPU server model is installed with the P800 GPU, the BIOS dynamically changes the Re-size BAR support option to Enable.
Condition: This symptom might occur if the P800 GPU is installed.
Symptom: When a GPU server model is installed with the P800 GPU, the BIOS dynamically changes the MMIO High Granularity option to 1.
Condition: This symptom might occur if the P800 GPU is installed.
Symptom: When the R5300 G6 server is configured with the X32 Switch board, OCP network adapters and 12LFF drives, the BIOS displays slot numbers of OCP network adapters incorrectly.
Condition: This symptom might occur if you view slot numbers of OCP network adapters on the R5300 G6 server configured with the X32 Switch board, OCP network adapters and 12LFF drives.
New Functions
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.42
Symptom: If EMR CPUs are installed on a dual-processor server, the Processor and Stepping information in the BIOS Setup are displayed as Unknown.
Condition: This symptom might occur if EMR CPUs are installed on a dual-processor server.
Symptom: The BIOS passes a fixed memory width value to the BMC, which needs to be adjusted based on the memory installation configuration.
Condition: None.
Symptom: Added support for Lynxi HP280 GPUs.
Condition: None.
New Functions
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.38
Symptom: Opened the Sharelink feature in the BIOS Setup Utility.
Condition: None.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.10.36
Symptom: In legacy mode, entering the BIOS setup utility might result in screen flickering for one to two seconds.
Condition: This symptom might occur if you enter the BIOS setup utility in legacy mode.
Symptom: When the server is configured with 5x8 DDR5 memory settings, the Rank Type option on the Advanced > Socket Configuration > Memory Configuration > Memory Topology page displays 10x4 in the BIOS setup utility.
Condition: This symptom might occur if you enter the BIOS setup utility for the server configured with 5x8 DDR5 memory settings.
New Functions
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.41
Symptom: The Post interface displays memory information in MHz instead of MT/s.
Condition: This symptom might occur if you view the memory rate from the BIOS Setup Utility.
New Functions
Upgrade recommendations
optional Upgrade
Problems Solved
Resolved problems in BIOS-6.10.39P01
Symptom: When the server is equipped with a dual-cloud disk BF3 intelligent network adapter and boots to BIOS Setup, NVMe cloud disks can be recognized but Virtio cloud disks cannot be recognized.
Condition: This symptom might occur when the server is equipped with a dual-cloud disk BF3 intelligent network adapter and boots to BIOS Setup.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.00.34
Symptom: For the key management module and shared network switch in the BIOS setup utility, some of their functions might fail to switch between Chinese and English when you press the hotkeys F3 and F2 to switch between the two languages.
Condition: This symptom might occur for the key management module and shared network switch in the BIOS setup utility when you press the hotkeys F3 and F2 to switch between Chinese and English.
Symptom: When you disable the disk boot option and enter the OS through a new boot option created at the same path, restart and enter the BIOS. As a result, the original disabled boot option is enabled again.
Condition: This symptom might occur if you disable the disk boot option and enter the OS through a new boot option created at the same path.
Symptom: When a USB LAN is connected to the network cable and PXE poll is performed in Legacy mode, the USB LAN cannot enter PXE.
Condition: This symptom might occur if PXE poll is performed in Legacy mode when you connect a USB LAN to the network cable.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.00.32
Symptom: If the server is equipped with a PCIe card with the speed reduction function, after you restart the server and enter the BIOS, no accompanying log is reported by the SDS.
Condition: This symptom might occur if you restart a server equipped with a PCIe card with the speed reduction function.
Symptom: The units of the Memory Frequency options are different in Chinese and English versions.
Condition: This symptom might occur if you view the Memory Frequency options in Chinese and English versions.
New Functions
Upgrade recommendations
Recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.00.27
Symptom: The help information for the Intel VT for Directed I/O option in the BIOS setup utility is inaccurate and needs to be modified.
Condition: This symptom might occur if you view the help information for the Intel VT for Directed I/O option in the BIOS setup utility.
Symptom: The system prompts an error message when you assign a static address to the IPv4 dedicated or shared network port on the BIOS setup utility in graphic mode.
Condition: This symptom might occur if you assign a static IP address to the IPv4 dedicated or shared network port.
Symptom: When you log in to the BIOS as a user with the user role and navigate to Server > BMC Network Configuration > IPv4/IPv6 Network Configuration, the Save button is not greyed out.
Condition: This symptom might occur if you log in to the BIOS as a user with the user role, navigate to Server > BMC Network Configuration > IPv4/IPv6 Network Configuration.
Symptom: In Legacy mode, when USB Boot is disabled in the BIOS setup utility and PXE is specified as a one-time boot option, the system enters the USB drive interface after polling.
Condition: This symptom might occur if USB Boot is disabled in the BIOS setup utility and PXE is specified as a one-time boot option for polling in Legacy mode.
New Functions
Upgrade recommendations
Problems Solved
Resolved problems in BIOS-6.00.24
Symptom: Removing the CMOS battery from the system board restores the Trusted Computing configuration to its default values.
Condition: This symptom might occur if you remove the CMOS battery from the system board.
Symptom: The authentication information displayed on the BIOS screen for newly introduced 16G DIMMs is inconsistent from the information displayed on the HDM interface.
Condition: This symptom might occur if you view authentication information for DIMMs from the BIOS and the HDM interface.
New Functions