Upgrade recommendations
Optionaled Upgrade
Problems Solved
Resolved problems in BIOS-6.30.42
Symptom: After disabling the memory module in setup, the corresponding memory under North Bridge shows "not present" instead of the expected "disabled".
Condition: Disabling the memory module in setup.
Symptom: When out-of-band (OOB) SOL redirect is enabled, the BIOS Setup interface displays abnormally in Chinese mode.
Condition: Enabling OOB SOL redirect and setting the language to Chinese.
Symptom: The upper limit of the BIOS-allowed RTC time-range (TRANGE) has been adjusted to 2099.
Condition: There is a requirement to adjust the upper limit of the BIOS-allowed RTC TRANGE to 2099.
Symptom: On the SOL and BIOS serial port redirect output page, the Console Redirections EMS option is displayed incompletely.
Condition: SOL output and serial port redirection under the BIOS serial port.
New Functions
Upgrade recommendations
recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.30.39
Symptom: The default PK for Secure Boot in the BIOS must use the one generated by H3C BIOS. The test PK provided by IBV must be removed.
Condition: This symptom might occur if the PK update for Secure Boot is required.
Symptom: When you import the customization package with the Enable Requested CPU min frequency and Requested CPU min frequency items set to non-default values, these items fail to be customized.
Condition: This symptom might occur if the customization package customizes the Enable Requested CPU min frequency and Requested CPU min frequency items.
Symptom: For the Moore S5000 module to be compatible with the R5500 G6 8U liquid-cooled model, you must enable Resizable Bar in the BIOS.
Condition: This symptom might occur if the R5500 G6 8U liquid-cooled model is installed with the Moore S5000 module.
Symptom: When the physical power button is pressed to start the server within a short period of time after the power source is connected, BMC does not finish starting, causing the BIOS to be unable to obtain a valid OEM flag to enter the load default process. This results in the BIOS value not matching the customized value.
Condition: This symptom might occur if the physical power button is pressed to start the server within a short period of time after the power source is connected, causing the BIOS to start up before the BMC finish startup.
Symptom: MBIST fails to report socket numbers from 1.
Condition: This symptom might occur if you enable MBIST and view the location information of the faulty memory reported by MBIST.
New Functions
Version:6.30.37P02(2025/5/21)
Upgrade recommendations
recommended Upgrade
Problems Solved
Resolved problems in BIOS-6.30.37P02
202503170751
Symptom: When Type 39 for SIMBIOS indicates a power supply is present, while the power supply is not installed.
Condition: This symptom might occur if you view Type 39 information when a power supply is not installed.
202503210313
Symptom: When you set a static IPv6 address in the BIOS, the prefix length and IPv6 router IP address are specified incorrectly.
Condition: This symptom might occur if you configure a static IPv6 address in the BIOS setup utility.
202503120259
Symptom: The R5500 G6 AMD added support for the P800 module.
Condition: None.
202503210947
Symptom: The GPU Configuration menu fails to display the P800 GPU module.
Condition: This symptom might occur if you access the BIOS setup utility to view information about the P800 GPU module after it is powered on.
New Functions