Supported products
Table 3 Supported hardware platforms
Product family
PUID
H3C UniServer R6900 G7
R6900-G7-MAE0
R6900-G7-MCE0
R6900-G7-MAL0
R6900-G7-MCL0
R6900-G7-MAS0
R6900-G7-MCS0
Restrictions and guidelines
None.
Version information
Version number
CPLD version: V002
Figure 1 Viewing CPLD version
![IMG_256]()
| NOTE: You can access the HDM Web interface of the server to identify the version on the System > System Overview > Others page as shown in the following figure. The figure is for illustration only. |
Table 2 Version history
Version number | Last version | Release date | Version type | Remarks |
V001 | First release | 2025-12-30 | Release version | |
V002 | V001 | 2026-04-08 | Release version | |
Supported languages
English.
Chinese.
Supported hardware platforms
Table 3 Supported hardware platforms
Product family | PUID |
H3C UniServer R6900 G7 | R6900-G7-MAE0 R6900-G7-MCE0 R6900-G7-MAL0 R6900-G7-MCL0 R6900-G7-MAS0 R6900-G7-MCS0 |
Hardware and software compatibility matrix
| CAUTION: To avoid an upgrade failure, use the following table to verify the hardware and software compatibility before performing an upgrade. |
Table 4 Hardware and software compatibility matrix
Item | H3C UniServer R6900 G7 |
Model | H3C UniServer R6900 G7 |
System board MCPLD version | V002 or later |
SCPLD | V002 or later |
VR | V001 or later |
HDM version | Version 3.01 or later |
BIOS | 7.00.19 or later |
Image file name and MD5 value | RS6M2C10S08002.bin:6d628d789da13fdf43f172c1af95bad0 RS6M2C10S09002.bin:e3e40475ecb521378ce6f3eda3c7775c |
Remarks | N/A |
(Optional) ISSU version compatibility matrix
None.
Update recommendation
This version is optional.
Update restrictions and guidelines
1.Make sure the server and the HDM client can reach each other.
2.As a best practice for bulk update, make sure you can update one server successfully before you update the remaining servers.
3.You must upgrade both CPLD1 and CPLD2 to a version later than V001.
4.During the update progress, make sure the network is normal and do not refresh the webpage.
5.Do not refresh the webpage during the update.
6.Do not power on or power off the server during the firmware update. If you fail to do so, some CPLD features might fail to operate correctly or exceptions might occur on the operation system.