• Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
Home Support Resource Center Software Download Servers

    Description

  • Description
  • Installation steps
  • Publish Description
  • Problems Solved
  • New Functions
  • Historical Versions
  • Description

    This software is used to upgrade the HDM version of the R4900LC G5 server

  • Installation steps

  • Publish Description

    Supported products

    H3C UniServer R4700 G5

    H3C UniServer R4900 G5

    H3C UniServer R4700LC G5

    H3C UniServer R4900LC G5

    H3C UniServer R4300 G5

    Restrictions and cautions

    Restrictions

    If no media images are mounted, the KVM window automatically closes when the HDM Web session times out.

    Each browser can establish only one session with HDM. If you attempt to establish two concurrent sessions from the same browser with different usernames, the first session will automatically end when the second session is established.

    Guidelines

    This version is available for all supported servers in this document.

    Make sure pop-ups are allowed on the browser.

    Version information

    Version number

    Image file names and the MD5 checksum:

    G3-HDM-3.52_signed.bin: a98af3f6b6105a7be90f1579c7929abe

    G5-HDM-3.52_signed.bin: b56e6150d683e113aaadf7bab592271e

    HDM version:

    Current version: 3.52

    Previous version: 3.51

     

     

    NOTE:

    You can access the HDM Web interface of the server to identify the HDM version in the Device information section of the Dashboard page.

     

    Supported languages

    HDM supports the following languages:

    Chinese.

    English.

    Supported browsers

    As a best practice, use one of the following browsers:

    IE 11 or higher.

    Firefox 50 or higher.

    Chrome 48 or higher.

    Supported hardware platforms

    H3C UniServer R4700 G5

    H3C UniServer R4900 G5

    H3C UniServer R4700LC G5

    H3C UniServer R4900LC G5

    H3C UniServer R4300 G5

     

    Hardware and software compatibility matrix

    CAUTION:

    The following version combinations are required to achieve certain special functions and are not mandatory.

     

    Table 1 Hardware and software compatibility matrix (for the R4900/R4700/R4900LC/R4700LC G5)

    Item

    Specifications

    Product family

    H3C UniServer R4900/R4700/R4900LC/R4700LC G5

    BIOS

    Version 5.74 or later

    CPLD

    Version 005 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 2 Hardware and software compatibility matrix (for the R4300 G5)

    Item

    Specifications

    Product family

    H3C UniServer R4300 G5

    BIOS

    Version 5.71 or later

    CPLD

    001 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 3 Hardware and software compatibility matrix (for the R6900 G5)

    Item

    Specifications

    Product family

    H3C UniServer R6900 G5

    BIOS

    Version 5.54 or later

    CPLD

    007 or later

    PFR CPLD

    005 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 4 Hardware and software compatibility matrix (for the R4900 G3/R4700 G3/R2900 G3/R2700 G3)

    Item

    Specifications

    Product family

    H3C UniServer H3C UniServer R4900 G3/R4700 G3/R2900 G3/R2700 G3

    BIOS

    2.00.66 or later

    CPLD (24 DIMMs)

    004 or later

    CPLD (16 DIMMs)

    004 or later

    EXP

    RS3E25B062.00.04 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 5 Hardware and software compatibility matrix (for the R6700 G3)

    Item

    Specifications

    Product family

    H3C UniServer R6700 G3

    BIOS

    Version 2.00.62 or later

    CPLD

    Version 003 or later

    STBCPLD

    Version 003 or later

    DB CPLD

    Version 005 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 6 Hardware and software compatibility matrix (for the R6900 G3)

    Item

    Specifications

    Product family

    H3C UniServer R6900 G3

    BIOS

    Version 2.00.62 or later

    NODE CPLD

    006 or later

    SMC CPLD

    006 or later

    PDB CPLD

    004 or later

    EXP

    Version RS6B24S013.00.01 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 7 Hardware and software compatibility matrix (for the E3200 G3)

    Item

    Specifications

    Product family

    H3C UniServer R4500 G3

    BIOS

    2.00.65 or later

    CPLD

    005 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 8 Hardware and software compatibility matrix (for the R8900 G3)

    Item

    Specifications

    Product family

    H3C UniServer R8900 G3

    BIOS

    Version 2.00.62 or later

    NODE CPLD

    Version 003 or later

    SMC CPLD

    Version 003 or later

    PDB1 CPLD

    Version 004 or later

    PDB2 CPLD

    Version 002 or later

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 9 Hardware and software compatibility matrix (for the E3200 G3)

    Item

    Specifications

    Product family

    H3C UniServer E3200 G3

    BIOS

    2.00.62 or later

    CPLD

    005 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 10 Hardware and software compatibility matrix (for the R4330 G5)

    Item

    Specifications

    Product family

    H3C UniServer R4330 G5

    Hygon 2 BIOS

    5.32 or later

    CPLD

    009 or later

    iMC

    iom E0711

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 11 Hardware and software compatibility matrix (for the R4330 G5 H3)

    Item

    Specifications

    Product family

    H3C UniServer R4330 G5 H3

    Hygon 3 BIOS

    5.79 or later

    CPLD

    009 or later

    iMC

    iom E0711

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 12 Hardware and software compatibility matrix (for the R4930 G5)

    Item

    Specifications

    Product family

    H3C UniServer R4930 G5

    Hygon 2 BIOS

    Version 5.32 or later

    CPLD

    Version 009 or later

    iMC

    iom E0711

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 13 Hardware and software compatibility matrix (for the R4930 G5 H3)

    Item

    Specifications

    Product family

    H3C UniServer R4930 G5 H3

    Hygon 3 BIOS

    Version 5.79 or later

    CPLD

    Version 009 or later

    iMC

    iom E0711

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 14 Hardware and software compatibility matrix (for the R4930LC G5 H3)

    Item

    Specifications

    Product family

    H3C UniServer R4930LC G5 H3

    Hygon 3 BIOS

    Version 5.73 or later

    CPLD

    Version 009 or later

    iMC

    iom E0711

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 15 Hardware and software compatibility matrix (for the R4950 G5)

    Item

    Specifications

    Product family

    H3C UniServer R4950 G5

    Rome BIOS

    Version 5.48 or later

    Milan BIOS

    Version 5.60 or later

    CPLD

    Version 00D or later

    iMC

    iom E0711

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 16 Hardware and software compatibility matrix (for the B5700 G5)

    Item

    Specifications

    Product family

    H3C UniServer B5700 G5

    BIOS

    Version 5.28 or later

    CPLD

    Version 004 or later

    iMC

    UCenter SSA 7.3 (E0709P04)

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 17 Hardware and software compatibility matrix (for the R5500 G5 Intel)

    Item

    Specifications

    Product family

    H3C UniServer R5500 G5 Intel

    BIOS

    Version 5.65 or later

    CPLD

    Version 006 or later

    iMC

    iom E0707

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 18 Hardware and software compatibility matrix (for the R5500 G5 AMD)

    Item

    Specifications

    Product family

    H3C UniServer R5500 G5 AMD

    Rome BIOS

    Version 5.48 or later

    Milan BIOS

    Version 5.52 or later

    CPLD

    Version 00A or later

    iMC

    iom E0707

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 19 Hardware and software compatibility matrix (for the R5500 K)

    Item

    Specifications

    Product family

    H3C UniServer R5500K

    BIOS

    5.65 or later

    CPLD

    001 or later

    iMC

    iom E0707

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 20 Hardware and software compatibility matrix (for the R5300 G5)

    Item

    Specifications

    Product family

    H3C UniServer R5300 G5

    BIOS

    Version 5.34 or later

    CPLD

    Version 005 or later

    iMC

    iom E0707

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 21 Hardware and software compatibility matrix (for the R5300 G5)

    Item

    Specifications

    Product family

    H3C UniServer R5300 G3

    BIOS

    2.00.63P10 or later

    CPLD

    006 or later

    iMC

    iom E0707

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 22 Hardware and software compatibility matrix (for the R4300 G3)

    Item

    Specifications

    Product family

    H3C UniServer R4300 G3

    BIOS

    2.00.66 or later

    CPLD

    005 or later

    EXP

    Single RAID: RS3EB24LN012.00.03 or later

    Dual RAID: RS3EB24LN022.00.03 or later

    iMC

    iom E0707H01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 23 Hardware and software compatibility matrix (for the H3C Uniserver B5700/B5800/B7800/B16000 AE G3 and H3C UIS B460/B580/B780/UIS9000 UISM G3)

    Item

    Specifications

    Product family

    H3C Uniserver B5700/B5800/B7800/B16000 AE G3

    H3C UIS B460/B580/B780/UIS9000 UISM G3

    BIOS

    B5700 G3/B5800 G3/B7800 G3/B460 G3/B780 G3/B580 G3: 2.00.43P01 or later

    B16000 AE/UIS9000 UISM: 1.00.09 or later

    CPLD

    003 or later

    EXP

    BS1M2C0S061.02.02 or later

    iMC

    iom E0715

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Upgrade restrictions and guidelines

    Make sure the software versions are compatible with each other. For more information, see "Hardware and software compatibility matrix."

    As a best practice, back up the configuration before you upgrade the firmware. For more information, see "(Optional) Backing up the current configuration."

    To upgrade both HDM and the BIOS, upgrade HDM first.

    Make sure the server operates correctly or is powered off during BIOS or HDM upgrade.

    During the upgrade, make sure the network connection is available and do not refresh the Webpage.

    As a best practice of bulk-upgrade from UniSystem, make sure you can upgrade one server successfully before you upgrade the remaining servers.

    To avoid HDM or operating system errors, do not power on or power off the server during the firmware upgrade.

    After the firmware is upgraded, delete the browsing history before you re-log in to HDM. For more information, see "Clearing the browser cache."

    Upgrade both the primary image and backup image to the same image version.

    For the R4950 G5 with a Rome processor, to upgrade the BIOS from a version earlier than 5.15 to version 5.15 or later, first upgrade HDM to version 2.32 or later. If you do not do so, black screen of death occurs at device restart.

    For the G3 Intel servers and G5 Intel servers of a version earlier than HDM-3.11 (excluded) and later than HDM-2.25 (included), configuration import might cause a power capping issue. As a best practice, disable power capping before upgrading HDM. You can disable power capping through IPMI or from the HDM Web interface.

    Upgrade recommendation

    This version is optional for upgrade. 

  • Problems Solved

    Resolved problems in HDM-3.52

    202411160309

    Symptom: The event log reports a power supply self-test error 15 days after you set the active/standby power supply mode for the server.

    Condition: This symptom might occur if you set the active/standby power supply mode for the server.

    202411250343

    Symptom: When you view the operation log from the HDM Web interface, the Web interface automatically returns to the login page.

    Condition: This symptom might occur if the operation log contains garbled information.

  • New Functions

    HDM-3.52

    HDM-3.52 added support of the following hardware options for the R5300 G5:

    Hexaflake C20 GPU

    Kunlunxin P800 GPU

    HDM-3.52 added support of the following hardware options for the R4900 G5:

    NIC-ETH330T-3S-4P network adapter

  • Version:3.52(2025/1/6)

    Upgrade recommendations

    optional for upgrade

    Problems Solved

    Resolved problems in HDM-3.52

    202411160309

    Symptom: The event log reports a power supply self-test error 15 days after you set the active/standby power supply mode for the server.

    Condition: This symptom might occur if you set the active/standby power supply mode for the server.

    202411250343

    Symptom: When you view the operation log from the HDM Web interface, the Web interface automatically returns to the login page.

    Condition: This symptom might occur if the operation log contains garbled information.

    New Functions

    HDM-3.52

    HDM-3.52 added support of the following hardware options for the R5300 G5:

    Hexaflake C20 GPU

    Kunlunxin P800 GPU

    HDM-3.52 added support of the following hardware options for the R4900 G5:

    NIC-ETH330T-3S-4P network adapter

    Version:3.51(2024/12/4)

    Upgrade recommendations

    optional for upgrade

    Problems Solved

    Resolved problems in HDM-3.51

    202402051053

    Symptom: The HDM Web interface does not display information about the NIC-BCM957508-P2100G-2P network adapter.

    Condition: This symptom might occur if you set FunCtion Mode to NPAR1.0 for NIC-BCM957508-P2100G-2P on the Advanced menu in the BIOS setup utility, save the configuration, and then restart the device.

    202410120250

    Symptom: The HDM Web interface mistakenly reports an uncorrected error on DIMMs..

    Condition: This symptom might occur if the server misinterprets M2M related registers when it reports MCA alarms.

    New Functions

    HDM-3.51

    HDM-3.51 added support of the following hardware options for the R5300 G5:

    CXMT 32G memory module.

    Version:3.50(2024/11/4)

    Upgrade recommendations

    optional for upgrade

    Problems Solved

    Resolved problems in HDM-3.50

    202409021893

    Symptom: For the R4900 G5, the HDM Web page displays that a drive missing alarm is present but no anomaly is detected under the system.

    Condition: This symptom might occur if an issue occurs with communicating with the storage controller to retrieve information during the HDM startup process.

    New Functions

    HDM-3.50

    HDM-3.50 added support of the following hardware options for the R4900 G5:

    Leadtek 4090D GPU.

    Union Memory UM311b 480G/960G/1.92T/3.84T SATA SSD.

    HDM-3.50 added support of the following hardware options for the R4930 G5 H3:

    Scaleflux CSD3000 7.68T NVMe drive

    NIC-ETH-N500L-FH-4P-GE network adapter

    HDM-3.50 added support of the following hardware options for the R5300 G5:

    metaScale-200S network adapter

    metaScale-200 network adapter

    HDM-3.50 added support of the following hardware options for the R5500 G5 AMD:

    3140H network adapter

    Version:3.49.01(2024/9/24)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.49.01

    202405141974

    Symptom: The server's input and output power values obtained through the Redfish interface are the same.

    Condition: This symptom might occur if you use the Redfish interface to obtain the power values for a server installed with an Intel processor.

    202408230652

    Symptom: When you change the user password through the HDM web page, if the ID in the interface URL and the ID in the BODY are inconsistent, the change can still succeed.

    Condition: This symptom might occur if the ID in the interface URL and the ID in the BODY are inconsistent when you change the user password through the HDM web page.

    202406191302

    Symptom: The R4900 G5 server intermittently shows the hard drive status as Ready.

    Condition: This symptom might occur if you configure logical drives under a PMC storage controller for an R4900 G5. The status of member drives of the logical drives might change to Ready.

    202407070061

    Symptom: After the server runs for a period, SDS logs cannot be downloaded via HDM, leading to repeated HDM reboots.

    Condition: This symptom might occur after the server runs for a period.

    New Functions

    HDM-3.49.01

    HDM-3.49.01 added support of the following hardware options for the R5300 G5:

    Enflame S60 GPU

    HDM-3.49.01 added support of the following hardware options for the R4900 G5:

    NS8500 G2 1.92&3.2&7.68TB SSD 

    HDM-3.49.01 added support of the following hardware options for the R4950 G5:

    SSD-7.68T-NVME-CD8P

    SSD-7.68T-NVME-7940M

    HDM-3.49.01 added support of the following hardware options for the R4930 G5 H3:

    SSD-1.92T-NVME-J5100

    Version:3.48.01(2024/7/17)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.48.01

    Symptom: Power consumption fluctuation occurs on the R4900 G5.

    Condition: This symptom might occur if the R4900 G5 uses multiple interfaces to obtain the monitoring information about power consumption.

    New Functions

    HDM-3.48.01

    HDM-3.48.01 added support of the following hardware options for the4 R900 G5:

    ES3500PV6 3.84T/7.68T NVMe drive

    Version:3.47(2024/5/29)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.47

    Symptom: Multiple devices report that the number of out-of-band user connections has reached the upper limit and the response from the IPMI command indicates that the session resources are insufficient.

    Condition: This symptom might occur if the sol activate and sol deactivate commands are executed in the script under pressure.

    Symptom: Eight R4900 G5 servers in the same rack abnormally shut down. After manual restart, the servers recover to normal.

    Condition: This symptom might occur if an abnormal external power input led to a secondary power alarm on the server.

    Symptom: Some indexes obtained from the Redfish API are abnormal.

    Condition: This symptom might occur if you use the Redfish API to obtain input and output power multiple times.

    Symptom: An HDM login failure occurs when you use a password containing percent symbols (%).

    Condition: This symptom might occur if a password used for HDM login contains percent symbols (%).

    Symptom: When you use the OID (.1.3.6.1.4.1.25506.13.1.2.1.2.2.1.1.7) to monitor temperature status on components according to the MIB and SNMP manuals, the component health status information is returned. The MIB and SNMP manuals are incorrect.

    Condition: This symptom might occur if you use the OID (.1.3.6.1.4.1.25506.13.1.2.1.2.2.1.1.7) to monitor the temperature status of components.

    New Functions

    HDM-3.47

    HDM-3.47 added support of the following hardware options for the R4900 G5:

    MCX515A-CCUT network adapter

    NIC-ETH-SP670-FHHL-2P 100G network adapter

    Dapustor R5 1.92&3.2&7.68TB drive

    HDM-3.47 added support of the following hardware options for the R5300 G5:

    Hanbo VA10 GPU

    HDM-3.47 added support of the following hardware options for the CX8028G G5:

    IB-MCX755106AS-HEAT-200Gb-2P

    HDM-3.47 added support of the following hardware options for the R5500K:

    VR chip compatible with the Infineon solution

    Version:3.46.01(2024/5/15)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.46.01

    Symptom: After you configure an NVMe drive, the life span read is 255, triggering a critical life span alarm.

    Condition: This symptom might occur if the system reads the life span of an NVMe drive after you configure the drive.

    New Functions

    HDM-3.46.01

    HDM-3.46.01 added support of the following hardware options for the R4900 G5:

    Dapustor R5101-1.92T/R5301-3.2T

    Version:3.45.01(2024/4/7)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.45.01

    None.

    New Functions

    HDM-3.45.01

    HDM-3.45 added support of the following hardware options for the R4900 G5:

    NIC-ETH-3S910-LP-2P-25G network adapter

    NIC-ETH-SF200T-LP-2P-GE network adapter

    NIC-ETH-SF400T-LP-4P-GE network adapter

    NIC-ETH-RP1000P2SFP-LP-2P network adapter

    Version:3.44.01(2024/2/5)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.44.01

    Symptom: After the R4900 G3 has been running for 497 days, some monitoring platforms cannot display SNMP v3 traps generated on the server.

    Condition: This symptom might occur is you view SNMP v3 traps on some monitoring platforms after the R4900 G3 has been running for 497 days.

    New Functions

    HDM-3.44.01

    None.

    Version:3.43(2024/1/4)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.43

    Symptom: The NVMe drive information in the physical view of the storage management page on HDM does not match the actual information when the following conditions are met:

    The R4930 G5 (H3) server is installed with the 25SFF drive backplane and the rear 4SFF Unibay drive backplane.

    NVMe drives are attached to the rear 4SFF Unibay drive backplane.

    Condition: This symptom might occur if the R4930 G5 (H3) server is installed with the 25SFF drive backplane and the rear 4SFF Unibay drive backplane and NVMe drives are attached to the rear 4SFF Unibay drive backplane.

    Symptom: HDM might mistakenly report a drive fault alarm on all the drives attached to an LSI storage controller on the server.

    Condition: This symptom might occur if an LSI storage controller is installed on the server.

    Symptom: BMC reports a power fault on the system board when a sudden AC power-off occurs due to an unstable power grid for the R4900 G5.

    Condition: This symptom might occur if a sudden AC power-off occurs due to an unstable power grid for the R4900 G5.

    New Functions

    HDM-3.43

    HDM-3.43 added support of the following hardware options for the R4930 G5 H3:

    SSD-3.2T-NVMe-PB6537-AIC

    SSD-6.4T-NVMe-PB6537-AIC

    SSD-3.2T-NVMe-J5310-AIC

    SSD-6.4T-NVMe-J5310-AIC

    SSD-7.68T-NVMe-J5110-AIC

    Hanbo GPU VG1000-64G-LP

    NIC-ETH-RP1000SFPH102-3S-10G-2P

    HDM-3.43 added support of the following hardware options for the R4900 G5:

    X710-T2L network adapter

    Version:3.42(2023/12/5)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.42

    Symptom: When the password validity is set on the server, hREST cannot obtain the related information.

    Condition: This symptom might occur when the password validity is set on the server.

    Symptom: Overtemperature occurs on the module if the R300 module is used on the R5500K.

    Condition: This symptom might occur if the R300 module is used on the R5500K.

    New Functions

    HDM-3.42

    HDM-3.42 added support of the following hardware options for the R4900 G5:

    Vastai VA1L GPU

    Vastai VA1-16G GPU

    Solidigm P5520 15.36T drive

    HDM-3.42 added support of the following hardware options for the R4930 G5 H3:

    Denglin GPU Goldwasser-L256

    SSD-7.68T-NVME-PB6531-AIC

    Longsys SATA SSD

    HDM-3.42 added support of the following hardware options for the R5300 G5:

    Iluvatar BI-V150 GPU

    Version:3.41.01(2023/11/27)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.41

    Symptom: When the password validity is set on the server, hREST cannot obtain the related information.

    Condition: This symptom might occur when the password validity is set on the server.

    Symptom: When drives are installed to the R4900 G5 with the 8SFF UniBay drive backplane, the drive locations displayed on HDM do not match the actual configurations.

    Condition: This symptom might occur if the R4900 G5 is installed with 8SFF UniBay drive backplane.

    Symptom: When an ADDDC error occurs, the server does not report the corresponding log information.

    Condition: This symptom might occur if an ADDDC error occurs on the server.

    Symptom: When the server is installed with a PCIe module that has MB in its name and an error occurs on the PCIe module, MCA suggests replacing the module. However, HDM shows a critical alarm on the system board.

    Condition: This symptom might occur if the server is installed with a PCIe module that has MB in its name and an error occurs on the PCIe module.

    Symptom: An SEL alarm of system detected the absence of a DIMM was mistakenly reported on the R5500 G5.

    Condition: This symptom might occur if a G5 Intel sever is installed with non-certified DIMMs and is restarted.

    New Functions

    HDM-3.41

    HDM-3.41 added support of the following hardware options for the R4900 G5:

    Solidigm P5520 15.36T drive

    Great Wall 2700W power supply

    IVA-CP24-VA

    HDM-3.40 added support of the following hardware options for the R4950 G5:

    Configuration only with the rear 4SFF UniBay drive backplane

    HDM-3.40 added support of the following hardware options for the R5300 G5:

    Iluvatar V100 (MR) GPU

    Version:3.41(2023/10/31)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.41

    Symptom: When the password validity is set on the server, hREST cannot obtain the related information.

    Condition: This symptom might occur when the password validity is set on the server.

    Symptom: When drives are installed to the R4900 G5 with the 8SFF UniBay drive backplane, the drive locations displayed on HDM do not match the actual configurations.

    Condition: This symptom might occur if the R4900 G5 is installed with 8SFF UniBay drive backplane.

    Symptom: When an ADDDC error occurs, the server does not report the corresponding log information.

    Condition: This symptom might occur if an ADDDC error occurs on the server.

    Symptom: When the server is installed with a PCIe module that has MB in its name and an error occurs on the PCIe module, MCA suggests replacing the module. However, HDM shows a critical alarm on the system board.

    Condition: This symptom might occur if the server is installed with a PCIe module that has MB in its name and an error occurs on the PCIe module.

    Symptom: An SEL alarm of system detected the absence of a DIMM was mistakenly reported on the R5500 G5.

    Condition: This symptom might occur if a G5 Intel sever is installed with non-certified DIMMs and is restarted.

    New Functions

    HDM-3.41

    HDM-3.41 added support of the following hardware options for the R4900 G5:

    Solidigm P5520 15.36T drive

    Great Wall 2700W power supply

    IVA-CP24-VA

    HDM-3.40 added support of the following hardware options for the R4950 G5:

    Configuration only with the rear 4SFF UniBay drive backplane

    HDM-3.40 added support of the following hardware options for the R5300 G5:

    Iluvatar V100 (MR) GPU

    Version:3.40(2023/10/7)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.40

    Symptom: When there is a partial power failure in the R4900 G3 server, the health LED turns red, and there are no alarm messages displayed on the HDM webpage.

    Condition: The symptom might occur when there is a partial power failure in the R4900 G3 server.

    Symptom: In R4930 G5 H3 servers with multiple drive backplanes, there is a low probability of receiving drive fault and missing alarm logs on HDM during the host startup process.

    Condition: The symptom might occur when R4930 G5 H3 servers are configured with multiple drive backplanes, and there is a low probability of receiving false disk alarms on HDM during the host startup process.

    Symptom: When performing fieldiag on R5500 G5 servers, there is a random occurrence of errors.

    Condition: The symptom might occur when R5500 G5 servers are paired with a specific version of HDM and fieldiag is executed in-band.

    New Functions

    HDM-3.40

    HDM-3.40 added support of the following hardware options for the R4900 G5:

    95 series storage controllers for 12LFF+2SFF UniBay configuration

    9560-8i storage controller for 8UniBay configuration

    HDM-3.40 added support of the following hardware options for the R4930 G5 H3:

    NIC-ETH-3S930-LP-2*100G

    HDM-3.40 added support of the following hardware options for the R5500 G5:

    NVIDIA A800 HGX 40G module

    Version:3.39(2023/9/11)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.39

    Symptom: Ucenter reports Unknown state of logical drives when the R4900 G3 is installed with LSI RAID controllers.

    Condition: This symptom might occur when the R4900 G3 is installed with LSI RAID controllers.

    Symptom: The physical view tab of the storage management page displays additional drive presence information when the R4900 G3 uses the 24 NVMe drive configuration.

    Condition: This symptom might occur when the R4900 G3 uses the 24 NVMe drive configuration.

    Symptom: When the R4300 G5 is installed with drives of multiple types, it takes a long time for SNMP WALK to obtain drive information.

    Condition: This symptom might occur when the R4300 G5 is installed with drives of multiple types.

    Symptom: When a G3/G5 server is installed with two LSI HBA modules, such as 9500-8i+ 9300-8i, the system reports Drive Fault alarms mistakenly.

    Condition: This symptom might occur when a G3/G5 server is installed with two LSI HBA modules, such as 9500-8i+ 9300-8i.

    Symptom: When the R5500K installed with an OCP network restarts after a stress test, the system reports OCP overtemperature alarms in bulk.

    Condition: This symptom might occur if you install an OCP network adapter on the R5500K, perform a stress test, and restart the DC power.

    Symptom: Heat dissipation issues occur on the R5500 G5 installed with a 332A network adapter. 

    Condition: This symptom might occur on the R5500 G5 when a 332A intelligent network adapter is installed and the system enters FAKE S5.

    New Functions

    HDM-3-39

    HDM-3.39 added support of the following hardware options for the R5300 G5:

    Nvidia H800 GPU

    Nvidia L40S GPU

    RG800 Pro GPU

    HDM-3.39 added support of the following hardware options for the R4930 G5 (H3):

    GPU-RG800-32GB-FHFL

    25SFF drive backplane PCA-BP-25SFF-2U-G5 used together with NVMe drives

    HDM-3.39 added support of the following hardware options for the R4950 G5:

    UN-RC-2FHFL-R3-2U-G5

    Version:3.38.01(2023/8/15)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM-3.38.01

    202307180160

    Symptom: UCenter reports that logical drives are in Unknown state on an R4900 G3 installed with an LSI RAID controller.

    Condition: This symptom might occur on an R4900 G3 installed with an LSI RAID controller.

    Symptom: The physical view of the storage management page displays extra drive presence information for an R4900 G3 with the 24 NVMe drive configuration.

    Condition: This symptom might occur on an R4900 G3 with the 24 NVMe drive configuration.

    202307120329

    Symptom: It takes a long time for SNMP WALK to obtain drive information for an R4300 G5 installed with multiple drives.

    Condition: This symptom might occur on an R4300 G5 installed with multiple drives.

    202308070270

    Symptom: The system reports Drive Fault alarms mistakenly if the G3 or G5 device is installed with two LSI HBA modules, such as 9500-8i and 9300-8i.

    Condition: This symptom might occur if the G3 or G5 device is installed with two LSI HBA modules, such as 9500-8i and 9300-8i.

    202307240022

    Symptom: The system reports OCP overtemperature alarms in bulk after you perform stress tests on an R5500K installed with OCP network adapters and restart the server.

    Condition: This symptom might occur after you perform stress tests on an R5500K installed with OCP network adapters and then perform DC restart.

    202307192176

    Symptom: Heat dissipation issues occur on an R5500 G5 installed with 332A network adapters.

    Condition: This symptom might occur if the system enters FAKE S5 on an R5500 G5 installed with 332A network adapters.

    New Functions

    HDM-3-38.01

    HDM-3.38.01 added support of the following hardware options for the R4900 G5:

    H460-B1 storage controller (no Micron chip)

    H460-M1 storage controller (no Micron chip)

新华三官网