• Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
Home Support Resource Center Software Download Servers

    Description

  • Description
  • Installation steps
  • Publish Description
  • Problems Solved
  • New Functions
  • Historical Versions
  • Description

    This software is used to upgrade the HDM version of the R4900 G6 Ultra server

  • Installation steps

  • Publish Description

    Products

    H3C UniServer R4300 G6

    H3C UniServer R4700 G6

    H3C UniServer R4700LE G6

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4900 G6

    H3C UniServer R4900LE G6

    H3C UniServer R5300 G6

    H3C UniServer R5350 G6

    H3C UniServer R5500 G6 Intel

    H3C UniServer R5500 G6 AMD

    H3C UniServer R4950 G6

    H3C UniServer R6700 G6

    H3C UniServer R6900 G6

    Restrictions and cautions

    Restrictions

    If no media images are mounted, the KVM window automatically closes when the HDM Web session times out.

    Each browser can establish only one session with HDM. If you attempt to establish two concurrent sessions from the same browser with different usernames, the first session will automatically end when the second session is established.

    For the new HDM firmware to take effect, restart HDM after update. The system will write the flash memory during the restart.

    Guidelines

    This version is available for all supported servers in this document.

    Make sure pop-ups are allowed on the browser.

    Version information

    Version number

    Image file names and the MD5 checksum:

    HDM2_1.70_signed.bin: 2ab7a89b3196b8f71ba8f04337cd8735

     

     

    NOTE:

    You can access the HDM Web interface of the server to identify the HDM version in the Device information section of the Dashboard page.

     

    Supported languages

    HDM supports the following languages:

    Chinese.

    English.

    Supported browsers

    As a best practice, use one of the following browsers:

    Edge 108 or higher.

    Firefox 90.0.0 or higher.

    Chrome 80 or higher.

    Safari 14 or higher.

    Supported hardware platforms

    H3C UniServer R4300 G6

    H3C UniServer R4700 G6

    H3C UniServer R4700LE G6

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4900 G6

    H3C UniServer R4900LE G6

    H3C UniServer R5300 G6

    H3C UniServer R5350 G6

    H3C UniServer R5500 G6 Intel

    H3C UniServer R5500 G6 AMD

    H3C UniServer R4950 G6

    H3C UniServer R6700 G6

    H3C UniServer R6900 G6

    Hardware and software compatibility matrix

    CAUTION:

    To avoid an update failure, use the following tables in this section to verify the hardware and software compatibility before performing an update.

     

    Table 1 Hardware and software compatibility matrix (for the R4950 G6)

    Item

    Specifications

    Product family

    H3C UniServer R4950 G6

    BIOS

    Version 6.30.27P01 or later

    CPLD

    Version 007 or later

    iMC

    iom E0707

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 2 Hardware and software compatibility matrix (for the R5500 G6 Intel)

    Item

    Specifications

    Product family

    H3C UniServer R5500 G6 Intel

    BIOS

    Version 6.00.25 or later

    CPLD

    Version 003 or later

    SWITCH CPLD

    Version 003 or later

    iMC

    iom E0715L01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 3 Hardware and software compatibility matrix (for the R5500 G6 AMD)

    Item

    Specifications

    Product family

    H3C UniServer R5500 G6 AMD

    BIOS

    Version 6.30.21 or later

    CPLD

    Version 003 or later

    SWITCH CPLD

    Version 003 or later

    iMC

    iom E0715L01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 4 Hardware and software compatibility matrix (for the R5300 G6)

    Item

    Specifications

    Product family

    H3C UniServer R5300 G6

    BIOS

    Version 6.00.25 or later

    CPLD

    Version 002 or later

    iMC

    iom E0715L01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 5 Hardware and software compatibility matrix (for the R4900 G6 Ultra, R4900/R4900LE G6, R4700/R4700LE G6)

    Item

    Specifications

    Product family

    H3C UniServer R4900 G6 Ultra, R4900/R4900LE G6, R4700/R4700LE G6

    BIOS

    Version 6.10.36 or later

    CPLD

    Version 005 or later

    iMC

    iom E0709

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 6 Hardware and software compatibility matrix (for the R4300 G6)

    Item

    Specifications

    Product family

    H3C UniServer R4300 G6

    BIOS

    Version 6.10.36 or later

    CPLD

    Version 001 or later

    iMC

    iom E0711P01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 7 Hardware and software compatibility matrix (for the R6700/R6900 G6)

    Item

    Specifications

    Product family

    H3C UniServer R6700/R6900 G6

    BIOS

    Version 6.10.35 or later

    CPLD

    Version 001 or later

    iMC

    iom E0711P01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 8 Hardware and software compatibility matrix (for the R5350 G6)

    Item

    Specifications

    Product family

    H3C UniServer R5350 G6

    BIOS

    Version 6.30.23 or later

    CPLD

    Version 003 or later

    iMC

    iom E0709

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 9 Hardware and software compatibility matrix (for the B5700 G6)

    Item

    Specifications

    Product family

    H3C UniServer B5700 G6

    BIOS

    Version 6.10.36 or later

    CPLD

    Version 002 or later

    UOA

    Version 3.00.02 or later

    iMC

    iom E0721

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Upgrade restrictions and guidelines

    Make sure the software versions are compatible with each other. For more information, see "Hardware and software compatibility matrix."

    As a best practice, back up the configuration before you update the firmware. For more information, see "(Optional) Backing up the current configuration."

    To update both HDM and the BIOS, update HDM first.

    Make sure the server operates correctly or is powered off during BIOS or HDM update.

    During the update, make sure the network connection is available and do not refresh the Webpage.

    To avoid HDM or operating system errors, do not power on or power off the server during the firmware update.

    After the firmware is updated, delete the browsing history before you re-log in to HDM. For more information, see "Clearing the browser cache."

    Upgrade recommendation

    This version is optional for update. 

  • Problems Solved

    Resolved problems in HDM2-1.70

    None.

  • New Functions

  • Version:1.75(2024/11/14)

    Upgrade recommendations

    optional for update

    Problems Solved

    Resolved problems in HDM2-1.76.01

    202409101938

    Symptom: HDM might restart and generates an operation log message about BMC warm reset.

    Condition: This symptom might occur if the system runs the IPMI script in the OS in an in-band manner and upgrades HDM in an out-of-band manner.

    202410100921

    Symptom: When an LDAP user logs in to HDM, the system prompts that the user password is incorrect.

    Condition: This symptom might occur if an LDAP user logs in to HDM after you set up the AD server and configure LDAP settings.

    New Functions

    Version:1.74(2024/9/24)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.74

    None.

    New Functions

    Version:1.73.01(2024/9/24)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.73.01

    None.

    New Functions

    Version:1.72(2024/7/4)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.72

    Symptom: When you send a configuration subscription request through Redfish, adding a path to the end of the server IP port will cause a request error.

    Condition: This symptom might occur if you add a path to the end of the server IP when sending a configuration subscription request through Redfish.

    Symptom: For the R4700 G6 server's Trimode configuration, if you first connect four onboard SATA + 4NVME to ensure the Trimode environment displays correctly, and then replace the last four NVME with SATA, the newly replaced SATA drives will report "disk missing" after a period. The DC then also reports "disk missing."

    Condition: This symptom might occur if you first configure four onboard SATA+4NVMe and then replace 4NVMe with 4SATA.

    Symptom: When the R4950 G6 server is configured with a BCM957508-P2100G network adapter (firmware version 222.1.68.0), HDM is unable to obtain the temperature of the network adapter.

    Condition: This symptom might occur when the R4950 G6 server is configured with a BCM957508-P2100G network adapter (firmware version 222.1.68.0).

    New Functions

    Version:1.71(2024/6/1)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.71

    Symptom: If you press the power button before HDM starts up, the device cannot starts automatically.

    Condition: This symptom might occur if you press the power button before HDM starts up.

    Symptom: When you upgrade the HDM firmware, select the manual restart method, and issue the warm reboot command (ipmitool mc reset warm), HDM fails to execute the upgrade process.

    Condition: This symptom might occur if you upgrade the HDM firmware, select the manual restart method, and issue the warm reboot command (ipmitool mc reset warm).

    Symptom: During bulk drive stress testing on the R4900 G6 server, an overtemperature error occurs on the MARVELL RAID controller in slot 1.

    Condition: This symptom might occur on the R4900 G6 server if the RAID-MARVELL-SANTACRUZ-LP-2i RAID controller and M.2 are installed.

    Symptom: Advancement in HDM system time leads to the inability to access the HDM page.

    Condition: This symptom might occur if you restart HDM and the HDM system time advances.

    Symptom: Servers equipped with an AMD processor get hang and are unable to automatically restart when a UCE occurs in the processor.

    Condition: This symptom might occur on a server equipped with an AMD processor when a UCE occurs in the processor.

    Symptom: If you access HDM using the IPMI tool, HDM fails to respond.

    Condition: This symptom might occur if you use the IPMI tool to visit HDM continuously for a long time.

    Symptom: On the R4950 G6 server using HDM2-1.69.01, if you execute the ipmi power cycle command repeatedly for restart tests, the device fail to start automatically.

    Condition: This symptom might occur on the R4950 G6 server using HDM2-1.69.01 if you execute the ipmi power cycle command repeatedly for restart tests.

    Symptom: If the R4950 G6 uses HDM2-1.69 or an earlier version together with BIOS-6.30.27P01, BIOS-6.30.29, or a version later than BIOS-6.30.29, HDM cannot obtain information on memory temperature, voltage, or current.

    Condition: This symptom might occur if the R4950 G6 uses HDM2-1.69 or an earlier version together with BIOS-6.30.27P01, BIOS-6.30.29, or a version later than BIOS-6.30.29.

    New Functions

    Version:1.70(2024/4/18)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.70

    None.

    New Functions

    Version:1.69(2024/3/19)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.69

    Symptom: A memory leakage might occur if you configure BIOS options in an out-of-band manner for the server.

    Condition: This symptom might occur if you configure BIOS options in an out-of-band manner for the server.

    Symptom: After you install the license and configure Kerberos settings, downgrading HDM to versions 1.61 earlier with configuration reserved might result in Web access issues. 

    Condition: This symptom might occur if you downgrade HDM to versions 1.61 earlier with configuration reserved after you install the license and configure Kerberos settings

    New Functions

    Version:1.68.01(2024/2/23)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.68.01

    Symptom: When you access HDM2 via the browser, the browser gets stuck and HDM is inaccessible.

    Condition: This symptom might occur if hardware interrupts are triggered continuously on HDM2 from the host side.

    Symptom: SNMP v3 traps cannot be displayed on some monitoring platforms after the server has been running for 497 days.

    Condition: This symptom might occur if SNMP v3 traps are sent after the server has been running for 497 days.

    Symptom: A memory leakage might occur after you configure BIOS options on HDM for the server

    Condition: This symptom might occur if you configure BIOS options on HDM for the server.

    New Functions

    Version:1.67.01(2024/1/22)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.67.01

    Symptom: In HDM2-1.67 version for the server, when HDM continuously receives URLs with special characters, the webpage becomes inaccessible.

    Condition: This symptom might occur if the server uses HDM2-1.67 and HDM continuously receives URLs with special characters.

    New Functions

    Version:1.67(2023/12/31)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.67

    Symptom: After an offline logical disk member reports the "in failed array" alarm, when creating or deleting a logical disk operation is performed in-band, the disk number in the log that resolves the "in failed array" alarm reported out-of-band is inconsistent with the triggered one.

    Condition: When an offline logical disk member reports the "in failed array" alarm, and a creation or deletion operation of a logical disk is performed in-band.

    Symptom: After installing the license, the MRT service will not take effect immediately.

    Condition: Importing the license through HDM.

    New Functions

    Version:1.26(2023/12/11)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.26

    Symptom: The R4900 G6 server fails to start up during an AC power-on stress test.

    Condition: This symptom might occur during an AC power-on stress test on the R4900 G6 server.

    Symptom: BMC restarts unexpectedly during an AC power-on stress test on the R4900 G6 server.

    Condition: This symptom might occur during an AC power-on stress test on the R4900 G6 server.

    New Functions

    Version:1.25(2023/11/1)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.25

    Symptom: Using the iHDT scandump feature on the R4950 G6 server can cause HDM to crash and restart.

    Condition: This symptom might occur if you use the iHDT scandump feature on the R4950 G6 server.

    Symptom: When you use UniSystem for batch operating system installation, the processing time may be long.

    Condition: This symptom might occur if you use UniSystem for batch operating system installation.

    New Functions

    Version:1.24.01(2023/10/18)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.24.01

    202310110571

    Symptom: The network adapter connection status is displayed as N/A when a 531F network adapter is used and the network adapter firmware is of version 224.1.102.0.00.

    Condition: This symptom might occur when a 531F network adapter is used and the network adapter firmware is of version 224.1.102.0.00.

    New Functions

    Version:1.24(2023/9/27)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-1.24

    Symptom: False alarms for secondary power supply are generated when the R4950 G6 uses the new BMC version together with CPLD of an old version.

    Condition: This symptom might occur if the R4950 G6 uses HDM2-1.23 and CPLD of a version earlier than V004.

    Symptom: When presence errors occur on the LSI storage controller, HDM does not report alarms.

    Condition: This symptom might occur after an alarm is triggered if an LSI storage controller is used with any server configuration.

    Symptom: The LSI storage controller has not obtained supercapacitor information but reports supercapacitor absence mistakenly.

    Condition: This symptom might occur when an LSI storage controller is used with any server configuration.

    New Functions

    Version:1.21(2023/7/17)

    Upgrade recommendations

    Problems Solved

    Resolved problems in HDM2-1.21

    202306160493

    Symptom: After you perform managed hot removal and hot insertion of an H3C-proprietary OCP network on an R4900 G6 server, the network adapter information in HDM is displayed as N/A.

    Condition: This symptom might occur after you perform managed hot removal and hot insertion of an H3C-proprietary OCP network on the R4900 G6 server.

    202306130725

    Symptom: HDM cannot obtain the CPU temperature information if the R4950 G6 server is installed with only one processor.

    Condition: This symptom might occur if the R4950 G6 server is installed with only one processor.

    Resolved problems in HDM2-1.20

    202306021550

    Symptom: The 9540 storage controller installed on the R4900 G6 server cannot be identified after BMC is restarted.

    Condition: This symptom might occur if you restart BMC when the R4900 G6 is installed with the 9540 storage controller.

    Resolved problems in HDM2-1.18

    202305160350

    Symptom: HDM reports a rating mismatch error on power supplies when the R4900 G6 server is not powered on.

    Condition: This symptom might occur, because the event log might mistakenly report load imbalance if the server is powered off and both power supplies have power outputs with a sum between 60 W and 100 W.

    Resolved problems in HDM2-1.17.01

    202305090206

    Symptom: The BMC restarts abnormally after the stress test is restarted on the R4900 G6 Ultra server with the 25SFF drive backplane.

    Condition: This symptom might occur if the R4900 G6 Ultra server is installed with the 25SFF drive backplane.

    Resolved problems in HDM2-1.17

    202302221699

    Symptom: In Legacy mode of R4900 G6, screen distortion occurs when H5 KVM self-starts and enters PXE.

    Condition: This symptom might occur if you set the Legacy mode, specify network as the first boot option, save the configuration, and then restart to enter PXE.

    Resolved problems in HDM2-1.15

    202304111883

    Symptom: A process restarts after an in-band stress test is performed on creating and deleting logical drives on the R4900 G6 server.

    Condition: This symptom might occur if an in-band stress test is performed on creating and deleting logical drives on the R4900 G6 server with the 9560 storage controller.

    Resolved problems in HDM2-1.14

    First release.

    New Functions

新华三官网